38
CÔNG TY CỔ PHẦN LƯƠNG THỰC THỰC PHẨM COLUSA-MILIKET COLUSA - MILIKET FOODSTUFF JOINT STOCK COMPANY

CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Embed Size (px)

Citation preview

Page 1: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

CÔNG TY CỔ PHẦN LƯƠNG THỰC

THỰC PHẨM COLUSA-MILIKET

COLUSA - MILIKET

FOODSTUFF JOINT STOCK COMPANY

Page 2: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

ENERGY SAVING AND ENERGY EFFICIENCY IN

INTENSIVE ENERGY ENTERPRISE

COLUSA - MILIKET

FOODSTUFF JOINT STOCK COMPANY

Page 3: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Presentation by

COLUSA - MILIKET

FOODSTUFF JOINT STOCK COMPANY

Presenter:

Mr. Nguyễn Anh Tuấn

Deputy General Director

Page 4: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

• Enterprise name: Colusa – Miliket Foodstuff Joint Stock Company

• Transaction name: Colusa – Miliket Enterprise

• Address: 1230 Kha Vạn Cân, Linh Trung ward, Thủ Đức Dist., HCMC

• Tel: (08) 38966835 - 38966772

• Fax: (08) 38960013

• Email: [email protected]; [email protected];

• Website: www.comifood.com; www.miliket.vn.com

• Representative: Mr. Võ Văn Út – Title: General Director

• Industry: manufacturing soft rice noodles, instant rice noodles, Chinese noodles,

• Number of labors (direct/indirect): 450 people/113 people.

ESTABLISHMENT AND DEVELOPMENT

Page 5: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

THE COMPANY’S PRODUCTS

Page 6: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

PRODUCTION LINES

SOFT RICE

NOODLES CONGEE

CHINESE

NOODLES

Page 7: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Implementation plans:

- Establishment of the energy management board

- Preliminary assessment of energy consumption in the

Company

- General staff meeting and announcement of commitments

to undertake measures to reduce energy consumption.

- Sending for energy audit institution

- Assessment of the solutions and opportunities after audit

- Development of plans to implement the recommendations

made by the audit in phases and by annual and 5-year work

plans.

Implementation of energy management, energy saving

and efficiency at COLUSA – MILIKET

Page 8: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Inefficient condensate recovery system

PRELIMINARY ASSESSMENT

Page 9: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Inefficient steam recovery system

TRƯỚC KHI THỰC HIỆN PRELIMINARY ASSESSMENT

Page 10: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Ineffective thermal insulation system

TRƯỚC KHI THỰC HIỆN PRELIMINARY ASSESSMENT

Page 11: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Assessment of baseline data

Consumption levels in 2008:

+ Coal: 422 kg of coal/ton of boiled noodles

+ Electricity: no monitoring

Consumption levels monitored daily since Feb. – May, 2009, after internal management

+ Coal: 400 - 420 kg of coal/ton of boiled noodles

+ Electricity: 69KWh/ton of boiled noodles at the boiler area

Consumption levels according to monthly sales records in May 2009

+ Coal: 430kg kg of coal/ton of boiled noodles

+ Electricity: monitoring gauge

Baseline data BEFORE IMPLEMENTATION OF THE MEASURES

+ Coal: 423 kg of coal/ton of boiled noodles

+ Electricity: 69KWh/ton of boiled noodles at the boiler area

TRƯỚC KHI THỰC HIỆN MEETING TO REPORT ON PRELIMINARY

ASSESSMENT DATA

Page 12: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

MEETING TO REPORT ON PRELIMINARY

ASSESSMENT

Page 13: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

MEETING FOR IMPLEMENTATION COMMITMENTS AND

ESTABLISHMENT OF ENERGY MANAGEMENT BOARD

Page 14: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

ENERGY AUDIT OF THE WHOLE COMPANY

ECC of HCMC PROVIDED CONSULTATION AND SUPPORTS FOR THE

AUDIT

Page 15: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

ENERGY AUDIT OF THE WHOLE COMPANY

ECC of HCMC PROVIDED CONSULTATION AND SUPPORTS FOR THE AUDIT

Page 16: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

ENERGY AUDIT OF THE WHOLE COMPANY

ECC of HCMC PROVIDED CONSULTATION AND SUPPORTS FOR THE AUDIT

Page 17: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

TRAINING IN OPTIMIZATION OF THE STEAM SYSTEM

Page 18: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

TRAINING IN ENERGY MANAGEMENT

Page 19: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Assessment after audit

• Identification of assessment focus

– Reduction of pollution (wastewater, exhaust gas)

– Reduction of water consumption

– Reduction of energy consumption

• Installation of gauges, monitoring consumption

levels to identify baseline values

• Assessment of water consumption

• Assessment of energy consumption (electricity,

coal)

Page 20: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Fried noodles Boiled noodles

< 100oC

3 bar 80%-85 %

10bar

15%-20%

Boiler

6 tons/h

Steam drum

Condensate

High pressure:4-5bar

High temperature: 130-150oC Oil tank

Heater

Oil tank

heater

60-70oC

Waste condensate Figure 2. Diagram of steam distribution at the Company

Su

pp

ly

wa

ter

tan

k

(38

oC

)

Condensate

tank (30%)

Diagram of boilers and steam distribution

Page 21: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Vapor trap system could be improved

Page 22: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

BOILER

Motors of suction - exhaust

fans and boiler runs at low

loads

Suction fan

Exhaust fan

Page 23: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Assessment and technical recommendations

Boiler efficiency: 65%

Reasons:

+ Abundant of oxygen (15 – 16%)

+ Use of mechanical damper for air supply

Solution 1 and 2: improving boiler efficiency

+ To reduce abundant oxygen to 7 - 8% by connecting a

sensor for abundant oxygen with the variator of suction/exhaust

fans.

Expected results: increasing boiler efficiency to 80%

Measurement: installation of gauge for daily boiler efficiency

Page 24: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

SOLUTION 2: Installation of

variator

Suction fan

Exhaust fan

BOILER

Page 25: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Control of abundant oxygen and assessment

of boiler efficiency

Water

Fuel 100%

Air

Boiler

Steam

Smoke

Water

Heat loss due to

residuum and

bottom water

discharge

Heat loss

from the

surface

Losses due to:

dry smoke

Vapor in the smoke

Humidity in fuel

Humidity in air

Unburned fuel

Diagram of Thermal Equilibrium of the Boiler

Page 26: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Assessment and technical recommendations

(continued)

Solution 4: Thermal insulation and

condensate recovery

Solution 3: Replacing the

steamgard

Page 27: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

STEAM-TRAP STEAMGARD

OPERATION BY CYCLES CONTINUOUS OPERATION

WITH MOTION COMPONENTS NO MOTION COMPONENTS

EASILY BROKEN, SHORT LIFE SPAN LONG TIME SPAN 10~15 YEARS

FAILURES DIFFICULT TO DETECT AND REPAIR ALMOST NO FAILURE

LOSS OF STEAM LIMITED LOSS OF STEAM

UNSTABLE TEMPERATURE AND SPRESSURE STABLE TEMPERATURE AND SPRESSURE

GUARANTEE ONLY 1 YEAR GUARANTEE 3 YEARS

Solution 1: Replacing steamgard

Page 28: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

IMPLEMENTATION OF THE SOLUTIONS AFTER AUDIT

Page 29: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

IMPLEMENTATION OF THE SOLUTIONS AFTER AUDIT

Page 30: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

IMPLEMENTATION OF THE SOLUTIONS AFTER AUDIT

Page 31: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Solution 3:

Replacing steamgard

IMPLEMENTATION OF THE SOLUTIONS AFTER AUDIT

Page 32: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

32

INSTALLATION OF MEASUREMENT GAUGES

Page 33: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

RECYCLE OF TREATED WASTEWATER

WASTEWATER TREATMENT SYSTEM

Page 34: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

CONDENSATE RECOVERY SYSTEM

Page 35: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

CERTIFICATE OF MERIT BY MINISTRY OF SCIENCE AND

TECHNLOGY FOR ENERGY EFFICIENCY IN ENTERPRISES

RESULTS ACHIEVED AFTER IMLEMENTATION

Page 36: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

ACHIEVEMENTS

Compliance with environmental standards

Wastewater achieved environmental standards

Saving of wastewater: > 200m3/day

Exhaust gases achieved environmental standards

Reduction of green house gases: 1700 tons

CO2/year.

Reduction of energy consumption: 450 TOE/year

Achieved economic benefits: > VND1 billion/year

SUSTAINABLE PRODUCTION DEVELOPMENT

Page 37: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Conclusions

• 1.Good opportunity to apply new

technology Steamgard.

• 2.Saving energy reduction of product

costs enhancement of competitiveness

for the enterprise in the market.

• 3.Experiences could be applied to other

areas in terms of saving.

• 4.Stabilizing market.

Page 38: CÔNG TY CỔ PHẦN LƯƠNG THỰC PHẨM COLUSA- · PDF filecÔng ty cỔ phẦn lƯƠng thỰc thỰc phẨm colusa-miliket colusa - miliket foodstuff joint stock company

Colusa – MILIKET

1230 Kha Vạn Cân, Linh Trung ward, Thủ Đức

district

THANK YOU FOR YOUR

ATTENTION

We would like to thank the Energy

Conservation Center of HCMC (ECC) for

their consultation, audit and recommendations

as well as opportunities for the Company to

implement the energy saving and energy

efficiency measures.