Vækstmediets fysiske
egenskaber
Vægt ved fuld vandmætning 960 kg/m3
Vægt i tør tilstand 430 kg/m3
Maksimum vandkapacitet 50-55 %
Vand permeabilitet 25-35 mm./min.
Kornstørrelse > 80 % 2-8 mm.
Total pore volumen > 80 %
Luft-volumen ved vandmætning > 25 %
PH 5-7
EC 15 MS/M
Modul: Modulmål: 535 X 405 mm. Højde grundmodul: 40 mm. Højde vækstlag: ca. 6 cm. Total byggehøjde: ca. 6 cm + planter Vægt fuld vandmættet: 45 kg./m2. Vandtilbageholdelse: ca. 25 liter/m2. Brandtestet efter: BROOF(t2) Grundmodul indeholder erosion sikring. Modul kan klæbes til underlag på vind udsatte flader. Bevoksning: Indeholder min. 8-10 sedumtyper hvor af 4-6 findes i den danske fauna. Vækstmedie: Vækst mediet er testet og godkendt efter de tyske FLL guidelines.
Datablad: Nature Impact Roof® modul
1
Naure Impact Roof systemopbygning
1
REVISIONSREMARKSMM/DD/YY
2345
Opbygning ud mod kantskinner 001
A
12 /10 /2012 ..._ _ /_ _ /_ _ ..._ _ /_ _ /_ _ ..._ _ /_ _ /_ _ ..._ _ /_ _ /_ _ ...
Plastmodul
Vækstlag
Sedum
Drænhuller: 96 huller/modul
80 mm.
60 mm.
40 mm.Kantskinne
2
Produktnavn Varenummer Produktbillede
Nature Impact Leaf Guard 220080
Nature Impact Leaf Guard
Frame220081
Nature Impact Leaf Guard
U-Frame220087
Nature Impact (Kantprofil) 220082
Nature Impact (Gavlprofil) 220083
Nature Impact (Støtteprofil) 220090
Nature Impact (Kantprofil 1 mm) 220089
Nature Impact Profilhjørne 220088
Nature Impact Profilhjørne (indv.) 220085
Nature Impact (Samleprofil) 220084
Tilbehør
Project name: Nature Impact
Date: 2012.11.29
Revision: 01
Revision date: -
Revised by: -
- -
0 0 0 0 0 0 0 0
12,5 2,2 12,5 1,7 12,5 2,4 25 25
15 3,8 15 3,1 15 3,5 35 8,2 35
20 4,5 25 8,2 20 6 45 45
25 4,5 35 11,7 25 8,2 55 55
30 10,1
35 4,5 45 13,2 35 12,4
40 14,0
45 4,5
MAX permitted
flow according to
DS/EN12056 for the
internal diameter
Ø50 1,7
MAX permitted
flow according
to DS/EN12056
for the internal
diameter Ø75 5,0
MAX permitted
flow according
to DS/EN12056
for the internal
diameter Ø110 13,8
MAX permitted
flow according
to DS/EN12056
for the internal
diameter Ø110 13,8
Test purpose
The purpose of this test is to obtain flow performance curves, for the relevant pipe dimensions, expressed as a relation between the water level and it's specific flow rate for the designed
Nature Impact green roof system. System refereing to a setup consisting of drain boxes, green plants, soil, outlet, and leaf guard incl leaf guard bracket.
*Every second drain box
protrusion in the first row from the
leaf gurad was canceled.
Test report
(flow test)
Product name: Nature Impact Leaf guard Created by: HEN
Revision Comments:
-
Test equipment
The test will be carried out on the JUAL test stand for outlet flow rate testing with a standard setup arrangement acc. To EN1253-2:2003 which means that the down pipe has been done
with a 1500 mm offset string and a total fall height of 3000 mm.
Additional test specification
In order to describe the flow capacity for the green roofs system the data has been based upon the standard definitions for outlet flow testing meaning the that the flow rate is
examined at different water levels resulting in a set of data from which a flow curve can be derived. The green roof test setup which has been added to the standard definition consists
of a green roof area of app. 1200x1200 positioned symmetric around a leaf guard. The fully saturated green roof drain boxes including soil and plants somewhat prevents the water
from rising the registrated water level is therefore the measure water level around the green roof section.
Measured values
Article number: 220081
Drawing no.: 0050711-500
Based upon the obtained flow rates it is concluded that the complete green roof system will be capable of draining a roof area in an effectiv way if the water will be able to penetrate
through the drain boxes as intended.
Ø50 (400x400 leaf guard) Ø75 (400x400 leaf guard) Ø110 (400x400 leaf guard) Ø110 (350x350 leaf guard)
Every second drain box protusion for the first row of drainboxes from the leaf guard was canceled.
www.jual.dk JUAL Outlets
JUAL A/S JUAL A/S JUAL A/S JUAL A/S · Industrivej 14 · DK-7130 Juelsminde · Ph (+45) 76831133 · Fax (+45) 75693737 · E-mail [email protected]
1200 mmNew test basis
Water level
Green roof
Leaf guard
14
0
2
4
6
8
10
12
14
16
0 10 20 30 40 50
Water flow [l/s]
Water level [mm]
Nature Impact
Performance curves
Ø50 (400x400 leaf guard)
Ø75 (400x400 leaf guard)
Ø110 (400x400 leaf guard)
15