52
Catalog & Manual Dentium Instruments for Total Solution

DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

Embed Size (px)

Citation preview

Page 1: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

Catalog & Manual

Dentium Instrumentsfor Total Solution

Page 2: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

IndexSurgical Guide Polymer Guide 04 Implant Guide 06

Sinus Instruments DASK 11 Osteotome Kit 16 Sinus Elevator 17

GBR Instruments RS Kit 19 GBR System 24 Harvest Drill 35

Others Help Kit 38 Temporary Shell 45 Dental Maintenance Tips 48

Page 3: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

Polymer GuideImplant Guide

Surgical Guide

Page 4: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

4

Dentium Instruments

Polymer GuideThermoplastic Surgical Template for Dental Implant Placement

• Fabricate precise surgical template in just minutes using hot water• Disposable material to promote control of infection and contamination• Titanium sleeve is compatible with Dentium Guide and Final Drills

Thermoplastic surgical templateFabricate an accurate surgical template

in just minutes, greatly reducing the lab and chairside time.

Suitable template shapePolymer Guide is designed to maximize contact

area over the adjacent teeth while allowing substantial field of view during implant surgery.

Fully compatible with Dentium Drill System

Improved infection/contamination controlTo ensure infection/contamination-free surgery every time, the Polymer Guides are made to be disposable.

Drill a hole in the stone model Apply of Polymer Guide on stone model

Insert the Guide Pin

Remove the Guide Pin

Soak the Polymer Guide in hot water above 65°C to soften up the material for easy molding.

Position the Polymer Guide intra-orally for drilling

Polymer Guide

Page 5: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

5

Dentium Instruments

[ Unit: mm, Scale 1 : 1 / mm ]

Single Standard (5ea)

PGSSK PGSCK

2.5 T

22

35

22

45

2.5 T

7* Average mesiodistal

width of a tooth* 1 fixed sleeve + 3 additional Sleeve holes

T Art. No.

2.5 XSG 34 35 S

Cantilever Multi-Ready (5ea)

T Art. No.

2.5 XSG 34 45 C

Stone Drill XGD 23 60 (1ea)

Guide Pin XGP 34 23 S (5ea)

Guide Drill Brushing (First) XPGB 19 26 (1ea)

Guide Drill Brushing (Second) XPGB 26 34 (1ea)

Additional Metal Sleeve(for Cantilever Multi-Ready) XPGS 34 25 A (5ea)

Polymer Guide

Page 6: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

6

Dentium Instruments

Surgical guide utilizing silicon spacer and unique parallel pin

• The tripod parallel pin is designed to take into consideration the mesiodistal width and drilling position in the edentulous area

• Parallel pins and Spacers are configured based on the average width of a tooth

Spacer + Guide Drill Ellipse Parallel Pin Final prosthesis

Spacer + Guide Drill Final prosthesisEllipse Parallel Pin + Tripod Parallel Pin

Implant Guide

Assist in the implant positioning as well as determining the width and the position of

the prosthetic components

The Guide Drill holes on the Tripod Parallel Pin help in prepping the

osteotomy in the correct orientation

The three legs of the Tripod Parallel Pin are of different lengths to accommodate varying widths of prosthesis for multiple unit bridges

Implant Guide

Page 7: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

7

Dentium Instruments

Guide Drill

Spacers

Ellipse Parallel Pins (x2)

Tripod Parallel Pins

XLD 22 35S

XLDSP 60S

XPP 2226 50G

XLDSP 70S

XPP 2226 70G

XLDSP 80S

XPP 2226 90G

XLDSP 90S

XPP 2226 11G

XLDSP 10S

Kit Contents

ISGK

6 7 8 9 10

14

16 15

XPP 2226 1416G XPP 2226 1719G

17

19 18

GUIDEØ2.2

Ø6.0

4.0 / 5.0 6.0 / 7.0 8.0 / 9.0

ELLIPSE PARALLEL PIN

14

16 15

17

19 18

10.0 / 11.0

Ø7.0 Ø8.0SPACER

Ø9.0 Ø10.0

4 6 8 10

Implant Guide

Page 8: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

8

Dentium Instruments

Spacers

Ellipse Parallel Pins

6

6

7

7

8

8

9

9 6.0

10

10

5

4

7

6

9

8

11

10

Diameter Art. No.

Ø 6 XLDSP 60S

Ø 7 XLDSP 70S

Ø 8 XLDSP 80S

Ø 9 XLDSP 90S

Ø 10 XLDSP 10S

Diameter Art. No.

Ø 4 / Ø 5 XPP 2226 50G

Ø 6 / Ø 7 XPP 2226 70G

Ø 8 / Ø 9 XPP 2226 90G

Ø 10 / Ø 11 XPP 2226 11G

Tripod Parallel Pins

Width Art. No.

14 / 15 / 16 XPP 2226 1416G

17 / 18 / 19 XPP 2226 1719G

2

Ø 2.3

8

2.5

8

4 6 8 10

8

2.5

8

1417

16

19

15

18

Implant Guide

Page 9: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

9

Dentium Instruments

Single Case

Multiple Case

Guide Drill Combination of Guide Drill and Spacer

Ellipse Parallel Pin

Dual Abutment Connection

Dual Abutment connection

Guide DrillCombination of Guide Drill and Spacer

Guide DrillApplication of Tripod and Ellipse Parallel Pin

Fixture placement with Healing AbutmentSuperLine FX5010

Fixture placement with Healing AbutmentNR Line NFX3611S / NFX4311S / NFX5011S

Final Drill Ø 3.6 ~ Ø 5.0

Final prosthesis

Final prosthesis

8

8

18

17

19

Manual

Incision

CountersinkØ 5.0

Final DrillingØ 3.0 ~ Ø 5.0

Implant Guide

Page 10: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

10

Dentium Instruments

DASK Osteotome KitSinus Elevator

Sinus Instruments

Page 11: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

11

Dentium Instruments

Dentium Advanced Sinus Kit (DASK)• Simple & easy access to sinus cavity • Broad exposure of bony walls with special instruments

* DASK Drill #1~5 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with internal irrigation DASK Drill #6 : Drill speed 800 to 1,200 rpm, 30~45N∙cm with external irrigation

DASK Drills

Stoppers | for XRT332035, XRT372035, XED331035D

Type DASK Drill # REF

Crestal Approach

DASK Drill # 1 XRT 332035

DASK Drill # 2 XRT 372035

DASK Drill # 3 XED 331035D

Lateral Approach

DASK Drill # 4 XRT 064025

DASK Drill # 5 XRT 084025

DASK Drill v# 6 XRT 083025

Drilling Depth L REF

08 10.6 XFDST 08

06 12.6 XFDST 06

04 14.6 XFDST 04

02 16.6 XFDST 02

XRT332035

XRT372035

XED331035D

XRT064025

XRT084025

XRT083025

[ Unit: mm, Scale 1 : 1.2 / mm ]

Ø3.3

12 10 8 6 4 2 0

12 10 8 6 4 2 0

Ø3.7

12 10 8 6 4 1 0

Ø3.3Ø1.6

Ø4.0

Ø6.0

Ø8.0

Ø1.5

Ø8.0Ø6.6

Ø1.5

[ Unit: mm, Scale 1 : 1 / mm]

Ø5.14Ø5.14

Ø5.14Ø5.14

10.616.614.612.6

XFDST08 XFDST06 XFDST04 XFDST02

DASK

Page 12: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

12

Dentium Instruments

Sinus Elevation Instruments

The distance from the alveolar crest to the sinus floor should be measured on x-rays prior to surgery. Site preparation is performed with final drills in sequence up to 1mm short of the sinus floor. Then DASK Drill #1 or #2 is used and the sinus floor is carefully approached with light apical pressure. When you feel the yielding of the sinus floor, remove the drill. Or, partial preparations with DASK Drill #1 or #2 and up-fracture with osteotomes can be performed.

When the sinus cavity is accessed, DASK Drill #3 is introduced and a much broader detachment from the sinus floor can be facilitated horizontally with hydraulic pressure thanks to the internal irrigation hole.

DASK Drill #3 can also be used for a lateral approach surgery.

* The internal irrigation not only provides a cooling effect, but also adds hydraulic pressure to slightly lift the sinus membrane during drilling.

DASK Drill #1XRT332035

DASK Drill #2XRT372035

DASK Drill #3XED331035D

[800~1,200 rpm]

Drills for Crestal Approach

REF XSE1L

REF XSE2L

REF XSE3L

REF XSE4L

[ Scale 1 : 0.68 / mm ]

DASK

Sinus Bur Kit

SDK

[800~1,200 rpm]

Page 13: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

13

Dentium Instruments

DASK Maintenance

• Please follow for legal regulations, as well as hygienic guidelines to prevent contamination and infection.

• Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device.

• It is important to use and follow, proper cleaning, disinfection and sterilization procedures.

• It is also important to follow the manufacturer’s recommendation on use of drills.

• Please keep a log as to how many times the drills were used.

• Drill usage is determined by surgical site not per patient. Bone density and usage determine the life of the drills .

• Drills should be considered for replacement after approximately 15- 20 uses based on bone density. Check drills frequently for wear.

To make a lateral window through the antrostomy (thin-out) approach.

To make a lateral window through the wall-off technique.

* DASK Drill #6 is used to cut and detach a bony island like a trephine bur from the lateral wall. Uncontrolled overdrilling may lead to sinus perforation and possible damage to the membrane. External irrigation is necessary when drilling.

* DASK Drill #4 or #5 is used to prepare a lateral sinus window using light pressure and rotating stokes. The DASK Drill #4 or #5 is designed to minimize the risk of sinus membrane perforation.

DASK Drill #5XRT084025

DASK Drill #6XST083025

DASK Drill #4XRT064025

Drills for Lateral Approach

1. All instruments, immediately after use, must be presoaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak overnight.

2. Scrub with a soft brush to remove any debris.

3. For internal irrigation drills, use a reamer or small gauge needle to internally cleanout the drills.

4. Before using an ultrasonic cleaner, wrap drills in a 2 x 2 gauze to prevent rubbing against each other.

5. Rinse thoroughly with warm water.

6. Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.

7. Dry completely and place back into kit.

8. Always check for damage or corrosion after rinsing and drying.

9. Seal the tray in a sterilization pouch.

10. Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufacturer’ s recommendations.

11. Store in a dry area at room temperature.

[800~1,200 rpm] [800~1,200 rpm]

Sterilization and Instrument Care Procedures

DASK

Page 14: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

14

Dentium Instruments

Crestal Approach (Sinus Lifting)

After Ø3.8 Final drilling, eliminate the residual bone (1mm) using a DASK Drill #1 or #2 (in hard bone) until you feel a slight drop.

Fill the sinus cavity with [OSTEON™ Lifting] graft material.

Fill and distribute OSTEON™ graft material evenly throughout the achieved space.

Placement of implant into the osteotomy

Detach sinus membrane using the dome-shape sinus curette.

Detaching the sinus membrane to createadequate space for graft material.

Manual DASK

Page 15: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

15

Dentium Instruments

Wall-off Technique

Thin-out Technique

Lateral Approach (Sinus Elevation)

DASK Drill #6 is used to cut a round bony island from the lateral wall like a trephine bur. Start to drill at a desired location and proceed until you see the shadow of the sinus membrane. Then, separate and lift the bony island up from the neighboring wall with a molt curette or a periosteal elevator. The bony island is repositioned back in its original position after bone augmentation.

The first laser mark is 1.5mm and the second is3.0mm. Overdrilling can cause sinus perforationand possible damage to the membrane.

Detach sinus membrane using the dome-shape sinus curette.

Elevate the sinus membrane to create adequate space for graft material.

Elevate the sinus membrane to create adequate space for graft material.

Fill the obtained space with [OSTEON™ Sinus] graft material.

The bony island can be repositioned after bone augmentation. Implant placed (SuperLine).

Thin down the lateral wall with DASK Drill #4 or #5 at a 45 degree angle to reachthe Schneiderian Membrane.

Move the DASK Drill #4 or #5 mesiodistallywith a gentle pressure until you get the desired shape and size of the window for bone augmentation.

DASKManual

Page 16: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

16

Dentium Instruments

Osteotome Kit• Osteotomes compress the bone laterally, providing denser bony interface rather than removing valuable bone from

the surgical site.

Osteotomes | Final drill type

[ Unit: mm, Scale 1 : 0.4 / mm]

ØBØA

XOF 20 A1

XOF 34 A1

XOF 38 A1

XOF 43 A1

XOF 48 A1

Type Art No ØA ØB

XOFKA

(Convex)

XOFK 20 A1 Ø1.7 Ø2.8

XOFK 34 A1 Ø2.3 Ø2.8

XOFK 38 A1 Ø2.7 Ø3.2

XOFK 43 A1 Ø2.8 Ø3.8

XOFK 48 A1 Ø3.0 Ø4.3

XOFBKB

(Concave)

XOFK 20 B1 Ø1.7 Ø2.8

XOFK 34 B1 Ø2.3 Ø2.8

XOFK 38 B1 Ø2.7 Ø3.2

XOFK 43 B1 Ø2.8 Ø3.8

XOFK 48 B1 Ø3.0 Ø4.3

Type A(Convex)

Type B(Concave)

Osteotome Kit

Page 17: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

17

Dentium Instruments

Sinus Elevator

Balloon inflation size(mm)

Injection Volume(cc)

• Makes the sinus lift easy and drastically reduce the possibility of membrane perforation.• Balloon expansion of 0.5cc saline equals 6mm of membrane elevation.

6.0~6.5mm

0.5cc injection = Ø 6mm~6.5mm

4.0mm

Detach the sinus membrane to create adequate space for graft material.

Elevate the sinus membrane through the balloon inflation.

Carefully insert the Sinus Elevator into the osteotomy.

Use [OSTEONTM Lifting] graft material to fill the sinus cavity.

Expand the balloon progressively. Placement of implant in the osteotomy.

Sinus Elevator

6.0, 1.0 X 6-lines

Ø3.70

Type Art. No.

Including Syringe GSB38

Balloon Only GSB38B

Page 18: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

18

Dentium Instruments

RS Kit GBR System

Harvest Drill

GBR Instruments

Page 19: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

19

Dentium Instruments

Ridge Spreader (RS) Kit• Allows the achievement of space for implantation through the spreading of the bone with chisel and without drilling• There are three types of Ridge Spreaders to create space up to Ø4.5• Convenient surgeries due to the compatibility with hand-piece and ratchet• Easy-to-use kit component

RS Kit

Page 20: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

20

Dentium Instruments

XRSK

Kit contents

RS Kit

Bone Chisel XBC305013

Ratchet XRCA1

Ridge Spreader Drills RS142435

RS203235

RS263635

Round Bur RS263635

Ratchet Adapter XRA3917

Mini Saw XDS8025

Page 21: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

21

Dentium Instruments

Diameter L Art. No.

Ø1.4 / Ø2.4 35 RS142435

Ø2.0 / Ø3.2 35 RS203235

Ø2.6 / Ø3.6 35 RS263635

Diameter L Art. No.

Ø4.0 35 XRB4035

Diameter L Art. No.

Ø8.0 25 XDS8025

Art. No. XRA3917

Art. No. XRCA1

Art. No. XBC305013

35

17

25

Ø1.4

Ø8.0

Ø2.4

Ridge Spreader Drills

Round Bur

Mini Saw

Ratchet Adapter

Ratchet

Bone Chisel

[ Unit: mm, Scale 1 : 1 / mm ]

[ Unit: mm, Scale 1 : 0.6 / mm ]

RS Kit

35

Ø2.0Ø3.2

35

Ø2.6Ø3.6

35

Ø4.0

Page 22: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

22

Dentium Instruments

RS Kit + NR Line + OSTEON™ II + Collagen Membrane

Incision

Expansion with Ridge Spreader (20~60rpm / 30~45 N∙cm) - Expanding alveolar bone ridge to make space for fixture

Fixture placement NR Line 3609W

Decortification

Cover Screw connection

Expansion with Bone Chisel

Application of graft material OSTEON™ ll

RS KitManual

Page 23: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

23

Dentium Instruments

Barrier membrane applicationCollagen Membrane

Suture

Dual Abutment connection Final prosthesis

Healing Abutment connection

RS KitManual

Page 24: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

24

Dentium Instruments

Guided Bone Regeneration (GBR) SystemGuided Bone Regeneration

• Allows the implantation of the GBR Technique with greater convenience• Multi-function membrane screw for membrane and/or abutment/plate fixation• Both GBR Abutment and Healing Abutment may be used with corresponding Plates and Screws

GBR Plates

• Supports membrane to hold up the graft material at desired volume• Easy to bend and cut• May overlap up to 3 plates with each abutment

Membrane Screws

• Multi-function membrane screws for membrane fixation and/or abutment/plate fixation

Membrane Pins

• Membrane pins for membrane fixation and/or plate fixation

Straight

GBR Plates

Mandibular Total Osteotomy

Tripod-Groove

Matrix

GBR Abutment Technique Healing Abutment Technique

GBR System

Page 25: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

25

Dentium Instruments

28

3.0

18

3.0 Top

Side0.3

4.5

4.5

4.5

32.7

3.0

30.5

21

5.0* The tripod-Groove Plates can be cut in desired length and be used like a Straight Plate

37

44

2.5

Ø 1.5

4.0

Ø 1.5

6.0

Ø 1.5

8.0

Ø 1.5

10.0

Ø 1.5

GBR Abutment Technique

GBR AbutmentØ3.5

Healing AbutmentØ4.0 - Ø9.5

Healing Abutment Technique

Top

Side0.3

18

0.3

Top

Side

28

Top

Side0.3

2.5

Ø 1.5

4.0

Ø 1.5

6.0

Ø 1.5

8.0

Ø 1.5

10.0

Ø 1.5

GBR System

Page 26: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

26

Dentium Instruments

4.0A/H 6.0 8.0

3.7

A/H

5.5

[ Unit: mm ]

2.5

Ø 1.5

4.0

Ø 1.5

6.0

Ø 1.5

8.0

Ø 1.5

10.0

Ø 1.5

Mandibular Total Osteotomy Technique

GBR System

GBR Mandibular Total Osteotomy

Page 27: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

27

Dentium Instruments

G/H Art. No.

2.0 GAB 35 20

[ Scale 1 : 1.5 / mm ]

G/H 2.0

Delivery Holder

2.0

Ø 3.5

GBR Abutment

* Compatible with the SuperLine Fixtures. Compatible with Tightening Tool: Screw Abutment Hex (3.2 hex). Use no more than 10N∙cm of torque when tightening the GBR Abutment to the fixture.

* Compatible with the SuperLine Fixtures. Use no more than 10N∙cm of torque when tightening the Healing Abutment to the fixture. Single use only.

H 5.0

G/H 3.0

Ø4.5

Healing Abutment

5.0G/H3.0

Ø 4.5

G/H H Art. No.

2.0 2.0 HAB 40 20 20 L

2.0 3.5 HAB 40 20 35 L

3.0 5.0 HAB 40 30 50 L

4.0 7.0 HAB 40 40 70 L

G/H H Art. No.

2.0 2.0 HAB 45 20 20 L

2.0 3.5 HAB 45 20 35 L

3.0 5.0 HAB 45 30 50 L

4.0 7.0 HAB 45 40 70 L

G/H H Art. No.

2.0 2.0 HAB 65 20 20 L

2.0 3.5 HAB 65 20 35 L

3.0 5.0 HAB 65 30 50 L

4.0 7.0 HAB 65 40 70 L

G/H H Art. No.

3.0 5.0 HAB 75 30 50 L

3.0 5.0 HAB 85 30 50 L

3.0 5.0 HAB 95 30 50 L

Diameter Ø4.0 Diameter Ø4.5

Diameter Ø6.5 Diameter Ø7.5 / 8.5 / 9.5

GBR System

GBR Products

GAB3520 and FX4510SW

HAB453050L and FX4510SW

Page 28: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

28

Dentium Instruments

Straight

[ Scale 1 : 1.5 / mm ]

[ Scale 1 : 1 / mm ]

[ Scale 1 : 1 / mm ]

Tripod-Groove

Matrix

Type L T Art. No.

Straight18 0.3 GBP 18 04 S

28 0.3 GBP 28 06 S

Type L T Art. No.

Tripod-Groove 21 0.3 GBP 21 13 T

Type L T Art. No.

Matrix 44 0.3 GBP 44 99 T

Type L T Art. No.

Tripod-Groove 21 0.3 GBP 21 13 TH

Type L T Art. No.

Straight18 0.3 GBP 18 04 SH

28 0.3 GBP 28 06 SH

GBR Plates

Augmentation Height (A/H) Art. No.

4.0 GBP 40 37 M

6.0 GBP 60 37 M

8.0 GBP 80 37 M

[ Scale 1 : 1.5 / mm ]

MTO

28

3.0

18

3.0 Top

Side0.3

Top

Side0.3

4.5

4.5

18

0.3

Top

Side

28

Top

Side0.3

4.5

32.7

3.0

30.5

21

5.0* The tripod-Groove Plates can be cut in desired length and be used like a Straight Plate

37

44

4.0A/H 6.0 8.0

3.7

A/H

5.5

GBR System

Page 29: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

29

Dentium Instruments

Membrane Pins

2.75

Ø 3.0

Ø 0.5

Pin Case | 10 pins per case

Membrane Screws

Screw Case | 10 screws per case

Membrane Pin with insertion tool

L Art. No.

2.75 GMT 2525 C

[ Scale 1 : 2 / mm ]

L Art. No.

2.5 GSC 15 02

4.0 GSC 15 04

6.0 GSC 15 06

8.0 GSC 15 08

10.0 GSC 15 10

L Art. No.

2.5 GSC 15 02H

4.0 GSC 15 04H

6.0 GSC 15 06H

8.0 GSC 15 08H

10.0 GSC 15 10H

[ Scale 1 : 1.5 / mm ]

can be used with GBR Abutment

GBR System

2.5

Ø 1.5

4.0

Ø 1.5

6.0

Ø 1.5

8.0

Ø 1.5

10.0

Ø 1.5

2.5

Ø 1.5

4.0

Ø 1.5

6.0

Ø 1.5

8.0

Ø 1.5

10.0

Ø 1.5

Ø 3.8

Page 30: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

30

Dentium Instruments

Screw Drill GMD 1228

Hand-piece Insertion Tool Ratchet GST 26 H

Hand-piece Adapter XMAA1

Torque Wrench Adapter XMA 21 W

Screw / Membrane Pin Insertion Tool GST 85

Instruments

Kit Contents

GBRK

GBR System

Page 31: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

31

Dentium Instruments

[ Unit: mm, Scale 1 : 1.5 / mm ]

10.0

Ø 1.2

Screw Drill

[ Unit: mm, Scale 1 : 0.7 / mm ]

GST 26H

GST 56

GST 85

COD

Screw / Membrane Pin Insertion Tools

Adapters | for Screw, Ball and GBR Abutments

2120

Ø 1.2

2.0

4.0

6.0

8.0 Assemble with Guide Drill Stopper

XLDST14 XLDST12 XFDST10 XFDST08

8.56.5

4.52.5

Compatible with Guide Drill Stopper

XLDST14 XLDST12 XLDST10 XLDST08

4.66.6

8.6 10.6

GBR System

Type Art. No.

Hand-piece XMAA1

Torque Wrench XMA 21W

Diameter Art. No.

Ø1.2 GMD 1228

Art. No.

GST26H

GST56

GST85

COD

Page 32: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

32

Dentium Instruments

Case 1 OSTEON™ II Collagen + GBR Plate (Straight)

Fixation of Plate0.3mm thickness /18.0mm length plate

Fixation of PlatePlate with Membrane Screw

GBR Abutment connectionSuperLine : FX4510SE

Application of graft materialOSTEON™ II

Fixation of Collagen MembraneMembrane with pin

Fixation of PlatePlate with Membrane Screw

Suture

GBR SystemManual

Page 33: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

33

Dentium Instruments

Case 2 OSTEON™ II Collagen + GBR Plate (Tripod -Groove)

GBR Abutment connectionSuperLine : FX4510SE

Application of graft materialOSTEON™ II

Fixation of Collagen MembraneMembrane with Screw

Fixation of PlatePlate with Membrane Screw

Suture

Fixation of Plate0.3mm thickness / Cut-out Tripod-Groove plate

Fixation of PlatePlate with Membrane screw

GBR SystemManual

Page 34: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

34

Dentium Instruments

Case 3 OSTEON™ II + GBR Plate (Matrix)

GBR Abutment connectionSuperLine : FX4510SE

Application of graft materialOSTEON™ II

Suture

Plate placement0.3mm thickness / Cut-out Matrix plate

Fixation of PlatePlate with Membrane Screw

GBR SystemManual

Collagen Membrane placement

Page 35: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

35

Dentium Instruments

Harvest Drill

Ø 3.35

Ø 4.4

Ø 6.14

Collect autogenous bone and prep osteotomy simultaneously and effectively using the specially designed drills, the Harvest Drills.

• Sharp, pointed tip to prevent drill chattering for precise drilling.• Drill stoppers applicable to control the depth of the drilling for safe and efficient bone harvesting, especially in the

buccal side of the ridge.• Recommended drill speed of less than 100 rpm / 50N∙cm helps preserve the vital autogenous bone.• Excellent clinical results may be achieved when harvested autogenous bone is combined with Osteon™ II.

8 101214

Ø 2.2

Ø 2.6

Ø 2.9

Ø 3.85

* Bone collection in the buccal side of ridge : 50~200rpm / 30~50N·cm

Diameter L Art. No.

Ø2.9 35 XFH 34 35

Ø3.35 35 XFH 38 35

Ø3.85 35 XFH 4335

Ø4.4 35 XFH 48 35

Diameter L Art. No.

Ø2.2 35 XFH 22 35

Diameter L Art. No.

Ø2.6 35 XFH 26 35

Harvest Drills

L Art. No.

15.9 XFHST04

35

35

35

35

35

35

15.9

Harvest Drill Stopper

First Guide Drill

Second Guide Drill

[ Unit: mm, Scale 1 : 1 / mm ]

4.0

Harvest Drill

Page 36: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

36

Dentium Instruments

* During the 4.3/4.8 fixture insertion into the bone density of D3~D4, the 3.35/3.85 harvest drilling process can be skipped.

XLD 2235 XLD 2635

Harvest Drill(Final Drill)

FirstGuide Drill

Ø 2.2

SecondGuide Drill

Ø 2.6

XFH 3435

3.4

Ø 2.9

3.8

Ø 3.35

XFH 3835 XFH 4335

4.3

Ø 3.85

4.8

Ø 4.4

XFH 4835

Final Drill

1 [2]

1 - First Guide Drill1000 rpm / 30~45N·cm with irrigation

2 ~ 4 - Harvest Drill 30~100 rpm / 30~50N·cm without irrigation

2 3 4

Harvest Drill

Page 37: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

37

Dentium Instruments

Help KitTemporary Shell

Dental Maintenance Tips

Others

Page 38: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

38

Dentium Instruments

Help Kit• Easy solution for critical problems which may occur in the prosthetics process• 5 tools in 1 kit (Screw Remover / Abutment Hex Remover / Screw Tap Repair Fixture Remover /

Cover & Abutment Screw Remover)• Compatible with most dental implant products now available on the global market• Heavy duty with robust design and proven materials

XIH

33

25

L Art. No.

25 XRF S2S

35 XRF S2

L Art. No.

20 XRHR 20

25 XRHR 25

Screw Remover

Abutment Hex Remover

Help Kit

2520

Page 39: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

39

Dentium Instruments

Type Art. No.

Tap XRSTR

11° Guide XRSG11

8 ° Guide XRSG8

Type Art. No.

Remover

XRFRTF

XRFRT

XRFRTO

Wrench XRFRW

L Art. No.

25 XRRHD

Screw Tap Repair

Fixture Remover

Cover & Abutment Screw Remover

Help Kit

25

11° 8°

252525

25

11° 8°

25

Page 40: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

40

Dentium Instruments

ApplicationTo remove the remaining screw when the abutment screw is broken inside the fixture.

AdvantageEasy to remove the broken screw, as well as protect the internal threads of the fixture from being damaged.

Usage

1. Set the torque of the implant motor to 30~50 rpm in a CCW (counterclockwise) direction.2. Assemble the tool with the hand-piece.3. Run the motor while keeping the tip of the tool appropriately contacted with the broken screw until successfully

removed.

*Caution: Do not overload the tool with pressure; apply moderate pressure.

1

3

2

4

Dual Abutment Use the friction force of the tool rotating counterclockwise to remove the screw.

Allow the screw to gradually come out in a swaying motion.

Hand-piece torque: 30~50rpm / Reverse

Screw Remover

Help KitManual

Page 41: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

41

Dentium Instruments

Application

To remove the remaining hex when the hex portion of an abutment is broken.

Advantage

Easy to remove the broken hex, as well as protect the internal threads of the fixture from being damaged.

Usage

1. Insert the tool inside into the remaining hex hole of the fixture inside. 2. Assemble the ratchet with the tool and rotate it in a CW (clockwise) direction to lock the tool tip with the remaining hex.3. Disengage the ratchet and remove the remaining hex by gently rocking the tool. 4. If necessary, the hole located in the upper portion of the tool may be used with the crown ejector (not included).

*Caution: Do not overload the tool with pressure; apply moderate pressure.

Abutment Hex Remover

1

3

2

4

Dual Abutment (Hex)

Once the tool is tightly locked to the hex remnant, disengage the ratchet. Gently rock the tool until the hex is successfully removed.

Rotate the tool clockwise so that the remaining hex gets tightly engaged to the tool.

Help KitManual

Page 42: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

42

Dentium Instruments

ApplicationTo recreate the internal thread lines of the fixture when it is damaged.

AdvantageEasy to recreate the internal threads with the help of the guides corresponding to different internal angulation(8, 11 degrees) of the fixture.

Usage

1. Place the guide with corresponding degree to the fixture.2. Assemble the tap tool with ratchet.3. Start tapping using the tap tool with appropriate torque. 4. If excessive debris accumulates, pause tapping and remove using suction.5. Repeat steps 3 and 4 until completed.

*Caution: Do not apply excessive torque onto the tap tool. It is highly recommended to use the ratchet after the initial engagement of the tool and the internal threads.

Screw Tap Repair

IMPLANTIUM / SuperLine 11°

Tap with the guide attached. Remove the tool and the guide to suction the debris.

SimpleLine II 8°

*If excessive debris accumulates, pause tapping and remove using suction.

Help KitManual

1

3 4

Page 43: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

43

Dentium Instruments

ApplicationTo remove the fixture when critically damaged with no other recovery options.

AdvantageEasy to remove the failed fixture without causing damage to the adjacent bone

Usage

1. Assemble the tool with ratchet, and insert it into the failed fixture to be removed.2. Gently rotate the ratchet in a CCW direction until the tool is tightly locked into the fixture.3. Continue to rotate the ratchet with greater torque in a CCW direction until the failed fixture is completely removed.4. Separate the tool from the removed fixture by rotating it in a CW direction. If necessary, use the wrench (included) to

hold the fixture while rotating the tool with ratchet in a CW direction.

*Caution: Sufficient irrigation should be applied to the tool to prevent excessive heating during the procedure.

Fixture Remover

IMPLANTIUM / SuperLine 11°

Art No. XRFRT Art No. XRFRTO

Rotate the tool in a counterclockwise direction until it is tightly locked into the fixture. Continue to rotate with additional toque untilthe failed fixture is completely removed.

Separate the tool from the fixture using the ratchet and the wrench that are included in the kit.

SimpleLine II 8°

Help KitManual

1

2~3 4

Page 44: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

44

Dentium Instruments

Loading downwardCover Screw

Abutment Screw

Rotate the tool counterclockwise until tightly locked into the 1.28 hex of the cover screw.

Rotate the tool counterclockwise until tightly locked into the 1.28 hex of the abutment screw.

ApplicationTo disengage the cover screw, healing abutment and abutment screw from the fixturewhen the 1.28 hex on the head is stripped or damaged.

AdvantageEasy to disengage the cover screw, healing abutment and abutment screw with stripped or damaged hex.

Usage

1. Assemble the tool with the ratchet and place it over the damaged 1.28 hex of the cover screw, healing abutment or abutment screw that needs to be removed.

2. Gently rotate the ratchet in a CCW direction to tightly engage the tapered top of the tool into the damaged 1.28 hex. 3. Continue to rotate the ratchet in a CCW direction with greater torque until the cover screw, healing abutment or

abutment screw is completely removed.

4. After the removal, rotate the ratchet in a CW to separate the tool and the removed component.

Cover & Abutment Screw Remover

Help KitManual

1

3

2

4 Loading downward

Page 45: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

45

Dentium Instruments

Temporary ShellPre-fabricated Temporary Crown

• Aesthetic appearance that mimics the natural tooth• Single and Multi-restoration for easy scissor-trimmed concept

Jaw PositionArt. No.

Regular Wide

Maxilla

Posterior-Left TS 24 27 R TS 24 27 W

Anterior TS 13 23 R TS 13 23 W

Posterior-Right TS 14 17 R TS 14 17 W

Mandible

Posterior-Left TS 44 47 R TS 44 47 W

Anterior TS 33 43 R TS 33 43 W

Posterior-Right TS 34 37 R TS 34 37 W

3.0˚

InterproximalMin. Thickness 2.0

OcclusalMin. Thickness 0.5

Temporary Shell

8.27.0

8.0

7.8

7.8

10.2

9.4

9.8

10.6

7.6

7.6

7.2

5.5

5.7

Regular

8.67.5

8.4

8.2

8.2

10.8

9.8

10.5

11.2

8.0

8.0

7.7

5.8

6.0

Wide

Page 46: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

46

Dentium Instruments

Contouring the lower surface of the crown to accommodate the emergence profile

Temporary Shell try-in

Healing

Placement of Temporary Shell

Fill acrylic resin into the Temporary Shell

Temporary Abutment Connection

Placement of the Temporary Shell

Temporary Abutment preparation

Temporary ShellManual

Page 47: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

Temporary Shell

Page 48: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

48

Dentium Instruments

Dental Maintenance TipsDisposable dental tips designed for the maintenance of dental implants including teeth grinding and polishing and plaque removal

Titanium Tips

Urethane Tip

Brush Tip

Type Part No.

Ti Brush GDMT-Ti 3.0

Type Part No.

Ti Brush GDMT-Ti 6.0

Type Part No.

Urethane GDMT-U

Type Part No.

Nylon Brush GDMT-B

39

22

Ø3

3

Ø2.35

17

35

12.5

8.6 Ø2.35

31.5

8.5

Ø6.2 Ø4.2 Ø2.35

23

Ø1

39

22

Ø3

6

17

Ø1

Dental Maintenance Tips

Ø2.35

Page 49: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

49

Dentium Instruments

Interdental Tips

Type Part No.

Nylon Brush GDMT-I-SSS

Type Part No.

Nylon Brush GDMT-I-M

Type Part No.

Nylon Brush GDMT-I-L

39

11

Ø2 Ø4Ø0.44

39

11

Ø3 Ø6Ø0.5

39

11

Ø4 Ø7Ø0.6

Dental Maintenance Tips

Ø2.35

Ø2.35

Ø2.35

Page 50: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

DENTIUMLONG-TERMCLINICAL DATA

2002. 05. 17Pre-op

2002. 09. 04Post-op

2003. 03. 15Final prosthesis

2002 2003 2004 2005 2006 2007 2008

Page 51: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

OVER A DECADE OF COMMITMENT TO THE BEST PRODUCTS FOR DENTISTS AND PATIENTS

2008. 04. 145 years

2013. 12. 0511 years

2013 2014 20152009 2010 2011 2012

11 YEARS

Page 52: DentiumInstruments - 덴티움 for Crestal Approach REF XSE1L REF XSE2L REF XSE3L REF XSE4L ... sinus membrane. Then, separate and lift the bony island up from the neighboring

HEAD OFFICE3105 Trade Tower, 513 Yeongdong-daero, Gangnam-gu, Seoul, Korea 135-731 www.dentium.com / [email protected]

Specifications are subject to change without notice. Some of the products listed in this catalog may not be available in the market due to pending approval.

1412 [Rev.2]

Catalog & Manual

Dentium Instrumentsfor Total Solution