28
Sealing Arrangements Sealing Arrangements For NP Make Dispensers For NP Make Dispensers Supplied to HPCL Supplied to HPCL 10 Oct. 2013 Page 1 of 28

DWP sealing For HPCL.ppt [Compatibility Mode].pdf

Embed Size (px)

Citation preview

  • Sealing ArrangementsSealing ArrangementsFor NP Make DispensersFor NP Make DispensersSupplied to HPCLSupplied to HPCLSealing ArrangementsSealing ArrangementsFor NP Make DispensersFor NP Make DispensersSupplied to HPCLSupplied to HPCL

    10 Oct. 2013 Page 1 of 28

  • 1. Multi Product Dispensers (Non 2T Mix) Page no. DPXA-2204 (2 Side 2 Product 4 Nozzle). 3-6 DPXA-2306 (2 Side 3 Product 6 Nozzle). 3-6 DPXA-2202H (2 Side 2 Product 2 Nozzle Heavy Duty) 7-11

    2. 2T Mix Dispensers DPC050 (Single Nozzle, 2T mix).. 12-18 DPXA-2202 Blender (2 Side 2 Product 2 Nozzle, 2T Mix) 12-18 DPXA-2101 light Blender (2 Side 1 Product 1 Nozzle 2T mix) 19-26

    ContentsContents1. Multi Product Dispensers (Non 2T Mix) Page no. DPXA-2204 (2 Side 2 Product 4 Nozzle). 3-6 DPXA-2306 (2 Side 3 Product 6 Nozzle). 3-6 DPXA-2202H (2 Side 2 Product 2 Nozzle Heavy Duty) 7-11

    2. 2T Mix Dispensers DPC050 (Single Nozzle, 2T mix).. 12-18 DPXA-2202 Blender (2 Side 2 Product 2 Nozzle, 2T Mix) 12-18 DPXA-2101 light Blender (2 Side 1 Product 1 Nozzle 2T mix) 19-26

    10 Oct. 2013 Page 2 of 28

  • DPXA- 2204 DPXA- 2306

    Two points in Electronics SectionTwo points in Electronics Section1) CPU Cabinet Sealing2) Electromechanical Totaliser Sealing

    One pointOne point in Hydraulics Sectionin Hydraulics Section3) Sealing of Pulsar side cover attached with meter

    (AUTOSET 500).

    Specification of DUStandard Duty Dispenser 2 Side 3 Product 6 Nozzles 2 Display (one, each side)

    Specification of DUStandard Duty Dispenser 2 Side 2 Product 4 Nozzles 2 Display (one, each side)

    One pointOne point in Hydraulics Sectionin Hydraulics Section3) Sealing of Pulsar side cover attached with meter

    (AUTOSET 500).

    10 Oct. 2013 Page 3 of 28

  • Sealing in the ElectronicSection of DU

    Sealing point no.1 (CPU cabinet)

    Sealing in the ElectronicSection of DU

    10 Oct. 2013 Page 4 of 28

  • Sealing point 2 (EMT Sealing)

    lead Seal on DisplayCover (under whichEMT is mounted)

    10 Oct. 2013 Page 5 of 28

  • Sealing point No. 3 (Pulsar cover sealing on meter, AUTOSET 500)

    10 Oct. 2013 Page 6 of 28

  • DPXA- 2202H

    Two points in Electronics SectionTwo points in Electronics Section1) CPU Cabinet Sealing2) Electromechanical Totaliser Sealing

    One pointOne point in Hydraulics Sectionin Hydraulics Section3) Sealing of Pulsar side cover attached with meter

    (AUTOSET 500).

    Specification of DUHeavy Duty Dispenser 2 Side 2 Product 2 Nozzles 2 Display (one, each side)

    One pointOne point in Hydraulics Sectionin Hydraulics Section3) Sealing of Pulsar side cover attached with meter

    (AUTOSET 500).

    10 Oct. 2013 Page 7 of 28

  • Sealing point 1 (CPU cabinet)

    10 Oct. 2013 Page 8 of 28

  • Sealing point 2 (EMT Sealing)

    lead Seal on DisplayCover (under whichEMT is mounted)

    10 Oct. 2013 Page 9 of 28

  • Sealing point No. 3 (Pulsar cover sealing on meter AUTOSET 500)

    10 Oct. 2013 Page 10 of 28

  • W&M Approval CopyW&M Approval CopyFor DPXAFor DPXA --SeriesSeries

    10 Oct. 2013 Page 11 of 28

  • DPXA-2202 Blender 2T Mix

    Two points in Electronics SectionTwo points in Electronics Section1) CPU Cabinet Sealing2) Electromechanical Totaliser Sealing

    Two points in Hydraulics SectionTwo points in Hydraulics Section3) Sealing of Meter Unit (NP 1000)4) Sealing of Lube Pump, Variator Box and Pulsar

    assembly by one wire as shown in the pictures.

    Specification of DUPost Mix Dispenser, variable % (0,2,3,4&5) 2 Side 2 Product 2 Nozzles 4 Display (Two, each side)

    Two points in Hydraulics SectionTwo points in Hydraulics Section3) Sealing of Meter Unit (NP 1000)4) Sealing of Lube Pump, Variator Box and Pulsar

    assembly by one wire as shown in the pictures.

    10 Oct. 2013 Page 12 of 28

  • Sealing point 1 (CPU cabinet)

    10 Oct. 2013 Page 13 of 28

  • Sealing point 2 (EMT Sealing)

    lead Seal on DisplayCover (under whichEMT is mounted)

    10 Oct. 2013 Page 14 of 28

  • Sealing wire

    Sealing lead

    Point no. 3Point no. 3rdrd Sealing of MeterSealing of Meter AsslyAssly..

    NP-1000 Meter

    Sealing lead

    10 Oct. 2013 Page 15 of 28

  • Point no. 4Point no. 4thth Sealing of Variator box, Pulser & Lube pump (Front View)Sealing of Variator box, Pulser & Lube pump (Front View)

    Sealing wire

    Sealing lead

    Pulser

    Variator Box

    10 Oct. 2013 Page 6 of 28

  • Point no. 4Point no. 4thth Sealing of Variator box,Sealing of Variator box, PulsarPulsar & Lube pump (Rear View)& Lube pump (Rear View)

    Sealing wire

    Lube Pump

    10 Oct. 2013 Page 17 of 28

  • W&M Approval CopyW&M Approval CopyFor DPXA Series 2T mixFor DPXA Series 2T mix

    10 Oct. 2013 Page 18 of 28

  • Two points in Electronics Section1) CPU Cabinet Sealing2) Electromechanical Totaliser Sealing

    Two points in Hydraulics SectionTwo points in Hydraulics Section3) Sealing of Meter Unit (NP 1000)4) Sealing of Lube Pump, Variator Box and Pulser

    assembly by one wire as shown in the pictures.

    Sealing Points for DPXSealing Points for DPX--A 2101 light BlenderA 2101 light Blender

    Two points in Hydraulics SectionTwo points in Hydraulics Section3) Sealing of Meter Unit (NP 1000)4) Sealing of Lube Pump, Variator Box and Pulser

    assembly by one wire as shown in the pictures.

    10 Oct. 2013 Page 19 of 28

  • DPXDPX--AA 2101 light2101 light Blender (2T Mix)Blender (2T Mix)

    10 Oct. 2013 Page 20 of 28

  • Point no. 1Point no. 1stst Sealing of CPU CabinetSealing of CPU Cabinet

    Sealing wire Sealing lead

    10 Oct. 2013 Page 21 of 28

  • Point no. 2Point no. 2ndnd Sealing of Display with TotaliserSealing of Display with Totaliser

    Sealing wire

    Sealing lead

    10 Oct. 2013 Page 22 of 28

  • Sealing wire

    Sealing lead

    Point no. 3Point no. 3rdrd Sealing of MeterSealing of Meter AsslyAssly..

    NP-1000 Meter

    Sealing lead

    10 Oct. 2013 Page 23 of 28

  • Point no. 4Point no. 4thth Sealing of Variator box,Sealing of Variator box, PulserPulser & Lube pump (Front View)& Lube pump (Front View)

    Sealing wire

    Sealing lead

    Pulser

    Variator Box

    10 Oct. 2013 Page 24 of 28

  • Point no. 4Point no. 4thth Sealing of Variator box,Sealing of Variator box, PulsarPulsar & Lube pump (Rear View)& Lube pump (Rear View)

    Sealing wire

    Lube Pump

    10 Oct. 2013 Page 25 of 28

  • W/M SEALING IN HYDRAUIC SYSTEM

    SEALING ONMETER PULSER

    SEALING ON LUBEPUMP

    10 Oct. 2013 Page 26 of 28

  • W&M Approval CopyW&M Approval CopyFor DPC050 BlenderFor DPC050 Blender

    10 Oct. 2013 Page 27 of 28

  • OUR CONTACTSG.E.M.S CONTROL & SUPPORT CENTERToll Free : 1800 11 2324 / 1800 103 2324

    PHONE NO- (+) 91 120 45 98 500FAX- (+) 91 120 45 98 600

    E-mail: [email protected]

    10 Oct. 2013 Page 28 of 28

    OUR CONTACTSG.E.M.S CONTROL & SUPPORT CENTERToll Free : 1800 11 2324 / 1800 103 2324

    PHONE NO- (+) 91 120 45 98 500FAX- (+) 91 120 45 98 600