    Module X04 Datasheet

    3

    Table of Contents

    1 PURPOSE..............................................................................................5

    2 BLOCK DIAGRAM.................................................................................5

    3 BRIEF TECHNICAL DESCRIPTION......................................................6

    4 LIST OF ESSENTIAL PARAMETERS...................................................6

    5 SUBJECT ILLUSTRATION WITH PARTICULAR PARTSLABELING.............................................................................................8

    6 LIST OF CONNECTION POINTS ..........................................................9

    7 LIST OF INDICATORS ..........................................................................9

    8 INDICATION AND LOCALIZATION OF ERROR CONDITIONS...........9

    9 LIST OF SETUP AND CONTROL ELEMENTS.....................................9

    10 LIST OF DIAGNOSTIC OUTPUTS ........................................................9

    11 REPLACEMENT PROCEDURE ..........................................................10

    11.1 DISASSEMBLY.............................................................................................................10

    11.2 ASSEMBLY..................................................................................................................10

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    4/12

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    5/12

    Module X04 Datasheet

    5

    1 PurposeThe X04 module provides a basic end-to-end integrity monitoring for ADS-Bsystems.

    2 Block Diagram

    1

    4

    2

    3

    Figure 2-1 X04 Module Block diagram

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    6/12

    Datasheet Module X04

    6

    3 Brief Technical DescriptionThe X04 module consists of following main parts:

    Overvoltage protection (OVP SSR ES0130A00230). EMC filter (EMCF ES0100A00553).

    SQB02 electronic block (ELB SQB02 ES0110A00271).

    SMA 40dB attenuator (ATT 6B-40).

    Two LED indicators serve as a signalization of operating states andconditions.

    4 List of Essential Parameters

    Electrical parametersCarrier frequency 1090 MHz

    Transmit Power + 0 dBm (peak power)

    Output impedance 50 , VSWR 1.3 max.

    Pulse and spectral characteristics ofthe transmitted signal

    Acc. to the Annex 10, Vol. 4.

    Transmit Message Rate Acc. to the Annex 10, Vol. 4.

    Transmit Message Format

    S mode reply DF18 (ES/NT)

    BDS code 0,6 extended squitter surface position.

    BDS code 0,8 extended squitter identification and

    category.

    Data InterfaceBi-directional RS232 link.

    (57600 baud rate, 8 data bits, 1 stop bit, no parity)

    GPS Data

    Available separately on the Data interface output with250 ms update period.

    Protocol NMEA 0183 v2.3.

    WAAS, EGNOS supported.

    ConfigurabilityField configurable by the proprietary messages.

    See table below.

    Power supply +18 V +32 V (nominal +24 V) DC

    Power consumption 3 W max.

    Mechanical parameters

    W x H x D(without holders and connectors)

    58 mm x 291 mm x 291 mm

    Weight 4 kg

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    7/12

    Module X04 Datasheet

    7

    Operational conditions Tested according to

    Temperature range

    -40 C +60 CSN ETS 300 019-2-4, class 4.1 E

    Climate specification

    Humidityrh < 0 %, 100 % >

    SN ETS 300 019-2-4, class 4.1 E

    IP67 MIL-STD-810F/METHOD 512.4

    Salt fog MIL-STD-810F/METHOD 509.4Environmental effects

    Fungus (Microbiotics) MIL-STD-810F/METHOD 508.5

    EMC CompliantEMI - SN EN 61000-6-3

    EMS - SN EN 61000-6-2

    Sinusoidal vibrations

    (a 1 g, f 200 Hz)

    SN ETS 300 019-2-4, class 4.1 E

    SN EN 60068-2-6 Fc, class 4M5

    Mechanical specificationShocks (a 25 g)Duration 6 ms

    SN ETS 300 019-2-4, class 4.1 E

    SN EN 60068-2-29, class 4M5,method Eb

    Storage conditions

    Climate specification -50 C +70 C SN EN 60068-2-14 Nb

    Reliability

    MTBF 30 000 hours

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    8/12

    Datasheet Module X04

    8

    5 Subject Illustration with Particular Parts Labeling

    Figure 5-1 X04 Module - Drawing

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    9/12

    Module X04 Datasheet

    9

    6 List of Connection Points

    Label Description

    1 Input Power supply.

    2 Input/output Data interface (bi-directional RS232 link).3 Input Signal from GPS receiving antenna.

    4 Output HF signal to transmitting antenna.

    Warning:Input 3 (GPS antenna signal) is not protected against atmosphericovervoltage. The input is permanently fed by direct current voltage of +5 V(current of 50 mA max.). Short circuit on this input shall permanently damagethe GPS receiver of the X04 module.

    7 List of Indicators

    Label Type Description

    PWR Green LED Constant light signaling of power supply presence.

    DIAG Yellow LED

    Module Diagnostic

    Operating states are indicated as follows:

    The LED diode flashes the equipment is in an active state.

    For a message with transmitted position, the light-on time is250 ms and light-off time is 250 ms.

    For a message without transmitted position, the light-on timeis 1 s and light-off time is 1 s.

    The diode is not on the equipment is in an inactive state.

    The diode lights constantly the equipment is in a failure.

    8 Indication and Localization of Error ConditionsThe device is provided with an indication of its own faulty states (seeparagraph 7).

    9 List of Setup and Control ElementsThe equipment lacks setup and control elements accessible to the customer.

    10 List of Diagnostic OutputsNo reserved diagnostic output is accessible to the customer.

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    10/12

    Datasheet Module X04

    10

    11 Replacement Procedure

    Figure 11-1 X04 Module Replacement

    11.1 Disassembly

    Remove connector shrink protections.

    Disconnect the supply cable, antenna cable, GPS or data cable.

    Disconnect the grounding cable.

    Slacken the locking screw, see figure.

    Eject the entire module upwards.

    Remove the module from the cabinet.

    11.2 Assembly

    Shift the module into the cabinet, suspend it in pertinent position.

    Tighten the locking screw.

    Connect the grounding cable.

    Connect data or GPS cable, antenna cable and supply cable.

    Mount connector shrink protections.

    Holders

    Locking screw

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    11/12

  • 7/23/2019 ES0195A00034_01_AJ_X04_opr

    12/12