1. Follow steps 4 & 5 .2. Remove five hex screws from control panel

bracket. Tilt bracket up and out of the way.(Water valve is mounted to bracket.)

3. Disconnect four dampening straps from tubattached by 5/16" hex screws.

4. To remove tub cover, lift out eight moldedtabs and pull cover off.

5. Remove agitator by grasping bottom andsharply pulling up.

6. Remove 7/16" hex bolt attaching air bellcoupling to transmission spline shaft.

TIP: To align agitator to replace, matchgrooves in air bell to grooves inside agitator.Fin is aligned with groove.

123C8381P

• The power must be disconnected before servicing by unplugging the machine ordisconnecting the circuit breaker.

• The machine must be electrically grounded through the grounding lead in the three-prongpower cord. The cord must be plugged into a properly installed and grounded applianceoutlet. If local codes require an additional ground connection, use a 16-gauge or larger wireto connect the washer cabinet to an established ground. In all cases the grounding methodmust comply with all local codes and ordinances.

1. Follow step 1  .2. Pull knob off switch to b e serviced.3. Using screwdriver, gently lift up tab.

2 To Remove Switches inControl Panel:

1 To Remove Control Panel:

4 To Remove Front Panel:

1. Locate two spring clips between cover andfront panel by aligning putty knife withgroove on either side of lid and cover. (See

illustration below.)2. Insert putty knife and push forward to release

clips.

TO REDUCE THE RISK OF ELECTRICAL SHOCK:4. The motor and tub assembly will now lean

forward after both front rod and springassemblies are unhooked at the platform.

5. Disconnect motor harness connector,grounding wire to frame and pressure switchhose at take off.

6. Disconnect drain hose inlet (black hose) attub.

7. Lift and push bottom of tub/motor assemblytowards the rear of the cabinet, and roll tubout under top lip of cabinet.

8. Pull tub out of cabinet by lifting it over on itstop as shown below.

9. Reverse procedure to reassemble.

9 To Service Transmi

1. Repeat steps 4 ,  5 , 6  ,2. Remove transmission drive p

belt as shown, and removing

3 To Remove Timer:

1. Follow step 1  .2. Remove Timer Knob assemblies.3. Remove timer harness connector.4. Remove 1/4" hex screw mounting timer to

bracket (if applicable).5. Lift tab and pull timer out to the left.6. Reverse procedure to reassemble.

1. Remove front panel using step 4  .2. Remove two 1/4" hex screws on front of

cabinet.3. Remove tape from lid switch connector and

disconnect.4. Remove cover/lid assembly.5. Reverse procedure to reassemble.NOTE: Tape must be replaced on lid switchconnector.

5 To Remove Cover/LidAssembly:

3. Rotate frontpanel forwardand lift offcabinet baselocator tabs.

4. Reverseprocedure toreassemble.

7. Remove left-handed 1-11/16"transmissionhub nut.This nut isaluminum,take care notto roundthe edgeswhen removingor replacing.

TIP: The word “LOOSEN” with an arrowAPPEARS ON THE NUT.

8. Lift spin basket out and set a side.

9. Reverse procedure to replace basket.

1. Repeat steps

4  , 5  , 6 .2. Remove split

ring andwasher fromtransmission.

7 To Service Tub/MotorAssembly:

8 To Service Motor/Clutch:

1. Repeatstep 4  .

2. Loosen four3/8" nuts onbottom of

motor. (Usea ratchetto speedoperation.)

3. Move motortowards thecenter to remove belt.

4. Rotate transmission to give motor clearance.Rotate motor to the back and pull out.

5. Proper belt tension is 1/2" deflection.6. Reverse procedure to reassemble.

WATER LEVEL SWITCHBEFORE DISCONNECTING HOSE FROM WATERLEVEL SWITCH, BE SURE WATER LEVEL INMACHINE IS BELOW BOTTOM OF WASH BASKET.AFTER RECONNECTING HOSE, PUT MACHINEIN SPIN FOR AT LEAST ONE MINUTE BEFORECHECKING OPERATION OF SWITCH.

6 To Remove Spin Basket:

IMPORTANT - RECONNECT ALLGROUNDED DEVICES

IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS,NUTS OR WASHERS USED TO COMPLETE A PATHTO GROUND ARE REMOVED FOR SERVICE, THEYMUST BE RETURNED TO THEIR ORIGINAL POSI-TION AND PROPERLY FASTENED.

IMPORTANT SAFETY NOTICETHIS INFORMATION IS INTENDED FOR USE BYINDIVIDUALS POSSESSING ADEQUATE BACK-GROUNDS OF ELECTRICAL, ELECTRONIC ANDMECHANICAL EXPERIENCE. ANY ATTEMPT TOREPAIR A MAJOR APPLIANCE MAY RESULT INPERSONAL INJURY AND PROPERTY DAMAGE.THE MANUFACTURER OR SELLER CANNOT BERESPONSIBLE FOR THE INTERPRETATION OFTHIS INFORMATION, NOR CAN IT ASSUME ANYLIABILITY IN CONNECTION WITH ITS USE.

4. Pull to remove harness connector, and turnswitch counterclockwise to remove fromkeyhole. Reverse procedure to reinstall.

Remove HarnessLift Tab

3 Locking Tabs

Lid Switch

1

2 4

5

3

3. Remove front rod and spring assembly(one at a time) by lifting motor tub assemblyup to take weight off suspension spring atlower portion of rod. Pull the spring assemblyout of the leg and platform assembly, andrepeat for rear rod and spring assemblies.Allow them to hang freely. The front and rearrod and spring assemblies have differentcolor springhousingsand shouldnot beswitched.

Remove 4 Motor Nuts

RemovePulley

Nut

3. After pulley is removed, remobolts mounting the transmissplatform assembly.

5. Remove platform.6. Lift transmission up and out.

and brake are one assembly areplaced as a component.

4. Remove four 1/2" hex bolts mplatform to tub.

7. Reverse procedure to reinsta

TIP: Take care to align the fourholes from transmission to plareinstalling transmission.

Air BellCoupler

7/16" Bolt

17502348G O

SpinBasket

Split Ring

LeftHandedThread

Nut

Washer1

Remove 4 Screws

Bottom oBasket

RemoveNut

Use ScrewdriverTo Lift Up Tab

Align Putty KnifeTo Groove In Lid