LEVOXIN
Activated hydrazine hydrate for corrosion control in steam generation and heating systems
Description
LEVOXIN is BAYER AG's trade name for a productconsisting of an aqueous solution of hydrazine (N2H4)and a small amount of organic activator.
LEVOXIN is a clear, slightly yellow liquid with anamine-like odor. Exposure to light and air may causethe slightly yellow color to become more brownish.
Chemical formula: N2H4 * H2O
General properties
Supply form
LEVOXIN is obtainable in the form of differentconcentrations of hydrazine:
LEVOXIN 64 ? 64 % N2H4LEVOXIN 51 ? 51 % N2H4LEVOXIN 35 ? 35 % N2H4LEVOXIN 22 ? 22 % N2H4LEVOXIN 15 ? 15 % N2H4
The number after the product name corresponds to thepercentage of N2H4 (pure hydrazine) contained in theproduct. The standard concentration is LEVOXIN 15with 15 % by wt. hydrazine. Its hydrazine hydratecontent is at least 23.5 %.
Hazard characteristic
Category 2 carcinogen
Chemical properties
Like non-activated hydrazine hydrate, LEVOXIN i s areactive nitrogen compound with strong reducingproperties.The corrosion-inhibiting effect of LEVOXIN is primarilybased on the activation and acceleration of theoxidation of Fe2+ ions, with the formation of passivatingoxide layers (magnetite). In addition, LEVOXIN is an
oxygen binder, with the only reaction products beingnitrogen and water.Thermal decomposition of LEVOXIN also generatesammonia, which helps to effect the necessaryalkalization of steam and condensate.Furthermore, LEVOXIN is an effective inhibitor in cold,oxygen-containing water and is therefore ideal for thewet preservation of systems which are temporarily outof action.
Application
Main areas of application
LEVOXIN is successfully used to inhibit corrosion in:
- high, medium and low pressure installations- steam and condensate lines- circulation heating systems- preservation during plant shutdowns- closed cooling systems
Restrictions on use
If LEVOXIN is to be used in heating media for warmingfoodstuffs or drinking water, certain regulations need to becomplied with, about which we would be glad to informyou.
Further information
See product information sheet LEVOXIN No. SP 30 01 e,edition 2000-06, and corresponding safety data sheets,which we would be happy to supply you.