PIPE LAY TENSION
1.0 INPUT DATA
Length of Pipe L 52.5m
Outer Diameter OD 6.625in
Pipeline Wall Thickness t 0.5in
Density of Steel ρst 7850 kg m3
Corrosion Coating Thickness tcorr 2.5mm
Corrosion Coating Density ρcorr 950kg m3
Concrete Coating Thickness tconc 0mm
Corrosion Coating Density ρconc 3044kg m3
Sea Water Denisty ρsw 1025kg m3
2.0 CALCULATION
Total Outer Diameter: Dtot OD 2tcorr 2 tconc Dtot 0.173 m
Pipe Area Apipeπ
4OD
2OD 2 t( )
2 Apipe 9.621 in
2
Corrosion Coat. Area Acorrπ
4OD 2 tcorr 2 OD
2
Acorr 2.079 in
2
Insulation Coat. Area Aconcπ
4OD 2 tcorr 2 tconc 2 OD 2 tcorr 2
Aconc 0 in
2
Massa of Pipe Mpipe Apipe L ρst Mpipe 2.558 103
kg
Massa of Corrotion Coat Mcorr Acorr L ρcorr Mcorr 66.896 kg
Massa of Concrete Coat Mconc Aconc L ρconc Mconc 0 kg
Total Mass Mtot Mpipe Mcorr Mconc Mtot 2.625 103
kg
Volume Total Vtot Acorr Apipe Aconc LVtot 0.396 m
3
Lay Tension Tens Mtot ρsw Vtot g Tens 21.759 kN