2
Supports power supply up to 440V High withstand voltage specification Use in areas where power supply fluctuations are severe, such as Southeast Asia. Adopted in semiconductor devices that require safety, reliability, and stability. 2 3 4 Allowable power supply fluctuation range 30-440V Transformer load can be used Application Features 1 Constant resistance load such as sheathed heater B3000 Single-phase Phase Control Type Thyristor general-purpose type Main circuit power Control circuit power Power control method Control input signal Output adjust method Alarm output Safety protection function Noise resistance Environmental specifications Withstand voltage /dielectric strength Usage environment Usage Voltage AC110-220-440V Factory setting Consumption current 30A 120A Spec100mA 200A Spec350mA Receive resistance 100Ω Closed action when abnormal maxDC30V Less than0.5A OPTION Main circuit overcurrent detection action when above130% Device Abnormal temp. detection action when SCR Latest temp.100Action at 80when 200A ・IEC61000-4-4 ・IEC61000-4-5 ・IEC61000-4-11 Fast transient burst immunity Lightning surge immunity Voltage dip, instantaneous power failure, voltage fluctuation immunity Single Phase AC100 440V Less than DC24V±10% Thyristor AC phase DC4-20mA DC0-5V DC0-10V Front POWER VR 0-100% Dry contact output Alarm action ALM Overcurrent protection Overheat protection Alarm reset switch EMC immunity requirements ・ IEC61000-4-3 RF conducted immunity SEMI requirement conformity Voltage sag immunity Fail-safe design compliant RoHS Between Power - Chassis more than DC500V 100MΩ / Between Power - Chassis AC2500V 1 min Temp.0 50℃ (Reduce load current to 85% above 40℃) HumidityBelow90% (non-condensingMain Specifications Series Need be set up

MTTインスツルメンツ株式会社 - Series B3000...MTT INSTRUMENTS,INC. 2-14-14 Miyahara,Yodogawa-ku, Osaka 532-0003 JAPAN TEL:+81-6-4866-5880 FAX:+81-6-4807-4550 Created

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MTTインスツルメンツ株式会社 - Series B3000...MTT INSTRUMENTS,INC. 2-14-14 Miyahara,Yodogawa-ku, Osaka 532-0003 JAPAN TEL:+81-6-4866-5880 FAX:+81-6-4807-4550 Created

Supports power supply up to 440VHigh withstand voltage specification

Use in areas where power supply fluctuations are severe, such as Southeast Asia.

Adopted in semiconductor devices that require safety, reliability, and stability.

2

3

4 Allowable power supply fluctuation range 30-440V

Transformer load can be used

Application

Features

1 Constant resistance load such as sheathed heater

B3000Single-phase Phase Control Type Thyristor general-purpose type

◆Main circuit power ◆Control circuit power◆Power control method◆Control input signal

◆Output adjust method◆Alarm output◆Safety protection function

◆Noise resistance

◆Environmental specifications◆Withstand voltage /dielectric

strength◆Usage environment

Usage Voltage AC110-220-440V Factory settingConsumption current 30A ~ 120A Spec:100mA 200A Spec:350mA

Receive resistance 100Ω

Closed action when abnormal ※maxDC30V Less than0.5A

OPTIONMain circuit overcurrent detection action when above130% Device Abnormal temp. detection action when SCR Latest temp.100℃ *Action at 80℃

when 200A

・IEC61000-4-4・IEC61000-4-5 ・IEC61000-4-11

Fast transient burst immunity Lightning surge immunity Voltage dip, instantaneous power failure, voltage fluctuation immunity

Single Phase AC100 ~ 440V Less than DC24V±10%Thyristor AC phase DC4-20mADC0-5VDC0-10VFront POWER VR 0-100%Dry contact outputAlarm actionALM Overcurrent protection

Overheat protection Alarm reset switch

EMC immunity requirements ・ IEC61000-4-3 RF conducted immunity

SEMI requirement conformity ・Voltage sag immunity Fail-safe design compliantRoHS Between Power - Chassis more than DC500V 100MΩ / Between Power - Chassis AC2500V 1 min Temp.:0 ~ 50℃ (Reduce load current to 85% above 40℃) Humidity:Below90% (non-condensing)

Main Specifications

Series

※Need be set up

Page 2: MTTインスツルメンツ株式会社 - Series B3000...MTT INSTRUMENTS,INC. 2-14-14 Miyahara,Yodogawa-ku, Osaka 532-0003 JAPAN TEL:+81-6-4866-5880 FAX:+81-6-4807-4550 Created

Dimension

Connection example

・Use shielded wires for signalwiring to prevent erroneouscontrol.

・Use 30 AWG power supply wiring(S) with AWG12 to AWG10.* Connector connection for30Atype

・For power supply wiring (S) over60A specifications, use AWG14 toAWG18.

・Install a thyristor breaker / fuse ifnecessary.

3030

3060

3120

3200

A

0

0

75

100

B

210

220

230

235

M4×2

M4×2

M5×4

M5×4

Mounting(mm) Mounting screw

Single-phase Phase Control Type Thyristor general-purpose type

SeriesB3000

制御入力(下表)

ヒーター電圧検出用

Type List

B3 AC phase control method, resistance to load, power regulator03061220

124

-L-G

30A60A

1.4 kg2.9 kg4.5 kg5.9 kg

W54×H200×D160W90×H210×D250W115×H220×D270W150×H227×D285

120A200A

AC110V(AC100-120V)AC220V(AC200-240V)AC440V(AC380-440V)

-1-2-3

DC4-20mA(Receive resistance 100Ω)DC0-5VDC0-10V

Over-current Alarm Overheat Alarm Option

Gradient volume-LG Select L/G at same time

Code Specification Dimension(mm) Weight

Current capacity

Power  ※Factory setting

Option

Control input type

MTT INSTRUMENTS,INC. 2-14-14 Miyahara,Yodogawa-ku, Osaka532-0003 JAPANTEL:+81-6-4866-5880FAX:+81-6-4807-4550