CalculationCompartment 1Compartment 2
Lu (Panjang) 2,7m6,4m
D (Diameter)3,18m3,22m
Q (Bulk Weight)4,4ton/m34,65ton/m3
F (Filling Degree)32%32%
Q (Grinding Media Charge)33,521Ton83,9725Ton
Compartement Power Consumption
Mencari h/D dan ah/Da(Arm of Gravity in relation to mill diameter)q(specific Charge %)
0,1400,57932,4
0,1450,58531,8
h/D = 0,143a = 0,583H= (h/D +1/2). DH= (0,143+1/2). 3,35H= 2,154 mCritical mill speedncrit = Compartement 1Compartement 2ncrit = ncrit = ncrit = 13,30 min-1 ncrit = 23,57 min-Operating mill speedn = Compartement 1Compartement 2n= n= n= 9,975 min-1 n= 17,68 min-1
Net Driving Power