11
Road Tunnel Lighting Guide John Rands CEng MILP Yerevan, Armenia, 20 April 2016 Ministry of Nature Protection of RA

Road Tunnel Lighting Guide - nature-ic.am€¦ · Bibliography . CIE: CIE 88:2004 2nd Edition, International Commission on Illumination Guide for the lighting of road tunnels and

Embed Size (px)

Citation preview

Road Tunnel Lighting Guide

John Rands CEng MILP

Yerevan, Armenia, 20 April 2016

Ministry of Nature Protection of RA

Contents Overview

• Road Tunnels - Overview • Styles Of Tunnel Lighting • Current Practice • Road Tunnel Lighting – Design & Performance • Short Tunnels • Materials & Installation • Summary Of Recommendations • Risk Assessment

2 "Green Urban Lighting" UNDP-GEF/00074869 project

Running Hours

3 "Green Urban Lighting" UNDP-GEF/00074869 project

Initial Design Requirement Prior to embarking on a lighting design or a lighting design specification for a road tunnel the following criteria will be required to be established: • Structural details of the tunnel. • Design / speed limit of approach road(s). • Stopping Distance (m) • Tunnel Class based on:

– Traffic Flow Rate – Traffic Mix

• Access Zone Luminance L20 (cd/m2) • K factor value based on Tunnel Class & Speed Limit • Threshold Zone Luminance based on L20 x K (cd/m2) • Total Threshold Zone Length = Stopping distance (m) • Interior Zone Luminance based on Tunnel Class & Speed Limit (cd/m2) • Exit Zone Luminance = 5 x Interior Luminance (cd/m2) • Exit Zone Length (m) • Road Surface Category (R1, C2 etc.)

"Green Urban Lighting" UNDP-GEF/00074869 project 4

Design and Performance Requirements (1)

5 "Green Urban Lighting" UNDP-GEF/00074869 project

Design and Performance Requirements (2)

6 "Green Urban Lighting" UNDP-GEF/00074869 project

Entrance Zone Performance Requirements

7 "Green Urban Lighting" UNDP-GEF/00074869 project

Conclusions per Evaluations • where LTP < 20%, artificial daytime lighting should always be provided; • where LTP > 80%, artificial daytime lighting is generally not needed; • where LTP is between 20% & 80%, the following additional process should be

followed to determine if daytime lighting is needed

8 "Green Urban Lighting" UNDP-GEF/00074869 project

Devices and Tools (1)

9 "Green Urban Lighting" UNDP-GEF/00074869 project

Devices and Tools (2)

10 "Green Urban Lighting" UNDP-GEF/00074869 project

Alternative Control

Guidance Lighting

Bibliography CIE: CIE 88:2004 2nd Edition, International Commission on Illumination Guide for the lighting of road tunnels and underpasses

BSI: BS 5489-2:2003+A1:2008 Code of practice for the design of road lighting – Lighting of Tunnels

CEN: CR 14380: 2003 (Technical Report) Lighting applications – Tunnel lighting

MCHW: Mechanical, electrical and communications work for road tunnels

11 "Green Urban Lighting" UNDP-GEF/00074869 project