6
Jun 7, 2022, page 1 Schutzvermerk nach DIN 34 beachten MV4- Hardware overview

Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Embed Size (px)

Citation preview

Page 1: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 1

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

MV4- Hardware overview

Page 2: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 2

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

RMQ

MI4-Text OP

MI4-Graphics OP

SCADA

MI4-Touch OP

MV4-Touch OP

Power

Price

SCADA

Communication&Monitoring

Command&Indication

MV4 – Hardware overview (placement)

Page 3: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 3

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

320 * 240

320 * 240

640 * 480

640 * 480

5,7“

5,7“

10,4“

10,4“

4 MbyteFlash

4 MbyteFlash

4 MbyteFlash

4 MbyteFlash

1

1

1

1

1

1

1

1

24 VDC

24 VDC

24 VDC

24 VDC

LCD-S

TN m

ono

LCD-S

TN c

olou

r

LCD-T

FT c

olou

rR

esol

utio

nD

ispl

ay s

ize

Proje

ct M

emor

yPro

g. /

Printe

r Por

t

Slots

PCM

CIA

slo

t for

proj

ect m

emor

yPow

er s

uppl

y

Hardware MV4 Series (Device overview)

MV4-150-TA1 (-xx1)

MV4-450-TA1 (-xx1)

MV4-170-TA1 (-xx1)

MV4-470-TA1 (-xx1)

MV4-570-TA1 (-xx1)MV4-570-TA2 (-xx1)

MV4-670-TA1/TA2 (-xx1)MV4-690-TA1/TA2 (-xx1)

640 * 480

640 * 480

10,4“ Seriall orPCMCIA

Serial orPCMCIA

640 * 480 10,4“ Serial orPCMCIA

1024*768 Serial orPCMCIA

2

2

2

2

1

1

1

1

1

1

2

2

24 VDC

100-240VAC

24 VDC / 100-240VAC

24 VDC / 100-240VAC10,4“

15,0“

* (-xx1) Front in brushed stainless steel

Page 4: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 4

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

COM PORTZB 4-601-IF1

ACTIVERROR

COM PORTZB 4-609-IF1

ACTIVERROR

MPI

ZB 4-604-IF1

ERRORACTIV

PROFIBUS DP

J1 J2 J3 J4

B

AMPB1-TP : RS485

DEFAULT

DEFAULT

RUNDEFAULT

CB-LoaderV 1.00

J7

STD ALT

J6

PRG RUN

J5

ON

OFFMPB2-TP : RS485

MPB1-TP : ALTMPB2-TP : ALT

ZB4-601-IF1

ZB4-609-IF1

ZB4-604-IF1

Hardware MV4 Series (Interface cards)

CAN outZB 4-607-IF1

ACTIVERROR

ZB4-607-IF1CAN in

Page 5: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 5

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

PCMCIA

FLASH

EEPROM

ZB4-908-SC1

ZB4-916-SC1

ZB4-932-SC1

ZB4-606-IF1 ZB4-607-IF1

ZB4-609-IF1

ZB4-604-IF1

MV4-150-TA1

MV4-450-TA1

MV4-170-TA1

MV4-470-TA1

MV4-570-TA1

MV4-570-TA2

MV4-670-TA1

MV4-670-TA2

MV4-690-TA1

MV4-690-TA2 ZB4-244-PK1

* (-xx1) Front in brushed stainless steel

MV4 – Hardware overview (ordering details)

Page 6: Schutzvermerk nach DIN 34 beachten 5-Jan-14, page 1 MV4- Hardware overview

Apr 10, 2023, page 6

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

PLC - xyz

ZB4-601-IF1Suconet K

ZB4-604-IF1PROFIBUS DP

Data exchange

ZB 4-604-IF1

ERRORACTIV

PROFIBUS DP

20

COM PORT ZB 4-601-IF1

ACTIV ERROR

Gateway Function