3
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. *Prices are indicative Mar 20, 2014 1 Product data sheet Characteristics GV3P13 TeSys GV3 - Circuit breaker - thermal-magnetic - 9…13A - EverLink BTR connectors Product availability: Stock - Normally stocked in distribution facility Price*: 404.00 USD Main Commercial Status Commercialised Range of product TeSys GV3 Device short name GV3P Product or component type Circuit breaker Circuit breaker application Motor protection Poles description 3P Network type AC Utilisation category Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Breaking capacity Icu = 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu = 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu = 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu = 6 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu = 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Thermal protection adjustment range 9...13 A Trip unit technology Thermal-magnetic Magnetic tripping current 182 A Complementary Mounting mode By clips By screws Mounting support Plate Rail Mounting position Horizontal Vertical Motor power kW 11 kW at 690 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz 5.5 kW at 400/415 V AC 50/60 Hz Control type Rotary knob [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ith] conventional free air thermal current 13 A conforming to IEC 60947-4-1 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 8 W

TeSys_GV3_GV3P13

Embed Size (px)

Citation preview

Page 1: TeSys_GV3_GV3P13

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

. *Pr

ices

are

indi

cativ

e

Mar 20, 20141

Product data sheetCharacteristics

GV3P13TeSys GV3 - Circuit breaker - thermal-magnetic -9…13A - EverLink BTR connectorsProduct availability: Stock - Normally stocked in distribution facility 

Price*: 404.00 USD

MainCommercial Status CommercialisedRange of product TeSys GV3Device short name GV3PProduct or componenttype

Circuit breaker

Circuit breakerapplication

Motor protection

Poles description 3PNetwork type ACUtilisation category Category A conforming to IEC 60947-2

AC-3 conforming to IEC 60947-4-1Network frequency 50/60 Hz conforming to IEC 60947-4-1Breaking capacity Icu = 12 kA at 500 V AC 50/60 Hz conforming to IEC

60947-2Icu = 100 kA at 400/415 V AC 50/60 Hz conforming toIEC 60947-2Icu = 100 kA at 230/240 V AC 50/60 Hz conforming toIEC 60947-2Icu = 6 kA at 690 V AC 50/60 Hz conforming to IEC60947-2Icu = 50 kA at 440 V AC 50/60 Hz conforming to IEC60947-2

[Ics] rated serviceshort-circuit breakingcapacity

50 % at 690 V AC 50/60 Hz conforming to IEC 60947-250 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 230/240 V AC 50/60 Hz conforming to IEC60947-2

Thermal protectionadjustment range

9...13 A

Trip unit technology Thermal-magneticMagnetic trippingcurrent

182 A

ComplementaryMounting mode By clips

By screwsMounting support Plate

RailMounting position Horizontal

VerticalMotor power kW 11 kW at 690 V AC 50/60 Hz

7.5 kW at 500 V AC 50/60 Hz5.5 kW at 400/415 V AC 50/60 Hz

Control type Rotary knob[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Ith] conventional free air thermal current 13 A conforming to IEC 60947-4-1[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2Power dissipation per pole 8 W

Page 2: TeSys_GV3_GV3P13

2

Mechanical durability 50000 cyclesElectrical durability 50000 cycles for AC-3 at 440 V InOperating rate 25 cyc/hRated duty Continuous conforming to IEC 60947-4-1Connections - terminals EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness :

flexible - with cable endEverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness :flexible - without cable endEverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness :solid

Tightening torque 44.25...70.8 lbf.in (5...8 N.m) - on EverLink BTR screw connectors- cable 0.05 in² (35mm²)44.25 lbf.in (5 N.m) - on EverLink BTR screw connectors- cable 0.04 in² (25 mm²)

Mechanical robustness Vibrations 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Shocks opened 30 Gn for 11 ms conforming to IEC 60068-2-27Shocks closed 15 Gn for 11 ms conforming to IEC 60068-2-27

Suitability for isolation Yes conforming to IEC 60947-1Phase failure sensitivity Yes conforming to IEC 60947-4-1Height 5.2 in (132 mm)Width 2.17 in (55 mm)Depth 5.35 in (136 mm)Product weight 2.12 lb(US) (0.96 kg)

EnvironmentStandards EN/IEC 60947-1

EN/IEC 60947-2EN/IEC 60947-4-1UL 508 type ECSA C22.2 No 14-05 type E

Product certifications ATEXBVCCCCSADNVGLGOSTLROS (pending)RINAUL

Protective treatment THIP degree of protection IP20 conforming to IEC 60529IK degree of protection IK09Ambient air temperature for operation -4...140 °F (-20...60 °C)Ambient air temperature for storage -40...176 °F (-40...80 °C)Fire resistance 1760 °F (960 °C) conforming to IEC 60695-2-1Operating altitude 9842.52 ft (3000 m)

Ordering and shipping detailsCategory 22366 - MAN STR PROTECTORS-GV1/GV3Discount Schedule I11GTIN 00785901492214Nbr. of units in pkg. 1Package weight(Lbs) 2.22Product availability Stock - Normally stocked in distribution facilityReturnability YCountry of origin FR

Page 3: TeSys_GV3_GV3P13

3

Contractual warrantyPeriod 18 months