V10k Auto Manu TI25100DE

Embed Size (px)

Citation preview

  • 8/13/2019 V10k Auto Manu TI25100DE

    1/2

    GAS FEED SYSTEM

    V10K

    MANUAL / AUTOMATIC CONTROL

    TECHNICAL

    INFORMATION

    ADVANTAGES

    Versatile gas feeder for

    wall-mounting

    Proven technology, excellent

    reliability and long service life

    Proven V-notch flow control

    technology providing accuracy

    and repeatability

    Rotameters with high resolutionand easy readability in

    15 capacities up to 15 kg/h

    Differential regulating valve for

    precise feed rate control at low

    vacuum levels and economical

    injector operation

    Operating range for automatic

    control mode 1: 20

    Vacuum gauge for visual

    operation monitoring

    Serviceability - components easily

    accessible

    V10k automatic control: optional

    fully automatic control by process

    controller (e.g. PCU-fuzzy or with

    actuator control 4 20 mA)

    V10k manual control: retrofit

    for automatic control (electric

    positioner) possible

    Available for all water treatment

    gases:

    Chlorine

    Carbon dioxide

    Ammonia

    Sulphur dioxide

    (for other gases consult)

    The gas feed systemsV10k automatic and manual

    control is the proven gas feed technology from

    Wallace & Tiernan for capacities up to 15 kg/h

    combining a standardised flexible design with

    user-selectable configurations. The V10k gas

    feeders operate according the indirect procedure

    i.e. operating under a vacuum that is produced at

    the injector where the metered gas (e.g. chlorine

    gas) is dissolved in the operating water and the

    resultant solution is discharged to the point of

    application. Gas flow control is achieved by the

    proven Wallace & Tiernan V-notch ensuring the

    well-known accuracy and repeatability.

    METHOD OF OPERATION

    The V10k gas feed systems operate under a

    vacuum that is produced at the injector and

    transmitted through the control unit to the pressure/

    vacuum regulating valve on the gas supply source.

    This diaphragm-operated valve is opened by the

    vacuum and allows the gas to flow to the control

    unit where it passes through the rotameter and the

    V-notch orifice. On the rotameter the gas flow rate

    is measured and indicated. Downstream of the

    V-notch orifice the gas passes the differential

    regulating valve which maintains a consistent feed

    rate regardless of changes in the operating vacuum.

    At the injector, the metered gas is dissolved in the

    operating water stream and discharged as solution

    to the point of application.

    Highest Safety by Remote Vacuum

    The remote vacuum principle (vacuum from the gas

    supply containers up to the injector) is the basic

    technology of this design. There are no gas lines

    under pressure. If any part after the supply container

    gets broken, no gas can leak out, but air will leak in.

    Therefore the remote vacuum technology stands for

    the highest safety level in gas feed systems.

    V-notch for Precise Gas Flow Control

    The V-notch control orifice, field proven in hundreds

    of thousands of installations around the world,

    provides reliable, consistent gas feed at any

    capacity. It consists of a precision-grooved plug that

    slides through an annular seat. Any position of the

    plug in the seat results in a specific orifice size and a

    corresponding feed rate. This results in accurate gas

    flow control and excellent repeatability.

    Due to their size and the configuration of the orifice,

    theV10k systems are resistant against fouling from

    contaminants in the gas supply.

    Control of the gas feed rate for the V10k manual

    control gas feed system is achieved manually by

    turning the adjustment knob, for theV10k automatic

    control gas feed system either manually or auto-

    matically via an electric positioner.

    Electric Positioner for Automatic control

    For automatic control, the V-notch plug is moved

    depending on the application requirements:

    Manual override is achieved by simply pulling the

    knob to disengage the drive motor

    3 sets of volt-free contacts for system control:

    manual override

    MAX position

    MIN position

    Feedback potentiometer for precise operation

    with the SCU or PCU-fuzzycontrollers

    4 20 mA actuator control (optional)

    Simple ratio control

    Feed rate adjustment by means of a dosing factor

    Connection to SPS control systems

    TI 25.100DE

    www.wallace-tiernan.com

    WALLACE & TIERNAN

    V10k automatic

  • 8/13/2019 V10k Auto Manu TI25100DE

    2/2

    Due to continual product development and improvement,

    certain specifications may change without prior announcement.

    WALLACE & TIERNAN

    Australia

    WALLACE & TIERNAN Pty Limited

    Level 1, 6 10 Talavera Road

    North Ryde, NSW 2113, AUSTRALIA

    Tel.: +61 2 9850 2800, Fax: +61 2 9850 2801Email: [email protected]

    Canada

    U.S. FILTER / WALLACE & TIERNAN

    250 Royal Crest Court

    Markham, Ontario L3R 3S1, CANADA

    Tel.: +1 905 944-2800, Fax: +1 905 474-1660

    France

    WALLACE & TIERNAN S.A.R.L.

    BP 150, 1/3 rue Pavlov

    F-78196 Trappes Cedex, FRANCE

    Tel.: +33 1-34 82 18 50, Fax: +33 1-30 50 98 08

    Email: [email protected]

    Germany

    WALLACE & TIERNAN GmbH

    Auf der Weide 10

    D-89312 Gnzburg, GERMANY

    Tel.: +49 8221-9040, Fax: +49 8221-904203

    Email: [email protected]

    Mexico

    U.S. FILTER Chem Feed Mexico SA De CV

    Via Jose Lopez Portillo 321

    Tultitlan, Edo. Mex., 54900 MEXICO

    Tel.: +52 55 2159-2959, Fax: +52 55 2159-2985Email: [email protected]

    Romania

    WALLACE & TIERNAN Romania srl.

    Str. Liviu Rebreanu nr. 6

    Bl B1 Sc. A, ap. 39, Sector 3, Bucuresti, ROMANIA

    Tel.: +40 21-3046011, Fax: +40 21-3046012

    Email: [email protected]

    United Kingdom

    WALLACE & TIERNAN

    Priory Works, Tonbridge

    Kent TN11 0QL, ENGLAND

    Tel.: +44 1732-771777, Fax: +44 1732-771800Email: [email protected]

    USA

    U.S. FILTER / WALLACE & TIERNAN Products

    1901 West Garden Road

    Vineland, NJ 08360, USA

    Tel.: +1 856-507-9000, Fax: +1 856-507-4125

    Represented by:

    TECHNICAL DATATI 050.400-10DD

    Gases and Scale Capacities:

    Chlorine: up to 15.0 kg/h

    Carbon dioxide: up to 8.0 kg/hSulphur dioxide: up to 10.0 kg/h

    Ammonia: up to 5.0 kg/h

    Feed Ranges:

    e.g. chlorine gas

    1 22.5 g/h 0.15 3.0 kg/h

    3 60.5 g/h 0.20 4.0 kg/h

    10 200.5 g/h 0.25 5.0 kg/h

    20 400.5 g/h 0.30 6.0 kg/h

    30 600.5 g/h 0.40 8.0 kg/h

    50 1000.5 g/h 0.50 10.0 kg/h

    75 1500.5 g/h 10.00 15.0 kg/h

    100 2000.5 g/h

    Operating Range (V10k automatic control):

    1: 20 for any rotameter

    Accuracy:

    4 % of F. S.

    Operating Temperature:

    +10C to +50 C

    Operating Vacuum:

    40200 mbar

    Operating Water Pressure at Injector:

    max. 21 bar at 20 C

    max. 13 bar at 30 C

    max. 10 bar at 40 C

    max. 5.9 bar at 50C

    4 20 mA actuator control (optional)

    Measurement Inputs:

    1 x 4 20 mA

    1 x servo motor position feedback

    1 x external dosing factor

    Relay Outputs:

    2 x non-isolated

    Power Supply:

    115/230 V AC, 50 60 Hz

    Power Supply (V10k automatic control):

    0.25 A at 230 V AC

    0.50 A at 115 V ACElectric Positioner (V10k automatic control):

    Operating voltages: 230 V 115 V

    50/60 HZ 50/60 Hz

    Rating: 19 mA 46 mA

    Time for 0100% move: 80 sec. 66 sec.

    Potentiometer: 1 kOhm 10 %

    Max. switching capacity: 1250 VA 150 W

    Enclosure: IP 67

    Available Configurations:

    with 5 rotameter (standard) or 10 rotameter

    4 kg/h, 10 kg/h vacuum regulator or

    higher capacities standard or with switch-over option

    injector size 1/3, 1 or 2

    standard or anti-siphon type

    Option:

    Vacuum contact pressure gauge for installation into the gas

    supply line for monitoring operating vacuum

    Dimensions:

    V10k automatic control incl. panel (W x H x D):

    with electric positioner: 369 x 880 x 185 mm

    with electric positioner and controller 580 x 880 x 185 mm

    V10k manual control:

    350 x 380 x 150 mm

    Weight:

    V10k automatic control with electric positioner 15 kg

    V10k automatic control with electric positioner

    and controller 20 kg

    V10k manual control 5 kg

    2/2005

    TI 25.100DE

    V10k manual