GAS FEED SYSTEM
V10K
MANUAL / AUTOMATIC CONTROL
TECHNICAL
INFORMATION
ADVANTAGES
Versatile gas feeder for
wall-mounting
Proven technology, excellent
reliability and long service life
Proven V-notch flow control
technology providing accuracy
and repeatability
Rotameters with high resolutionand easy readability in
15 capacities up to 15 kg/h
Differential regulating valve for
precise feed rate control at low
vacuum levels and economical
injector operation
Operating range for automatic
control mode 1: 20
Vacuum gauge for visual
operation monitoring
Serviceability - components easily
accessible
V10k automatic control: optional
fully automatic control by process
controller (e.g. PCU-fuzzy or with
actuator control 4 20 mA)
V10k manual control: retrofit
for automatic control (electric
positioner) possible
Available for all water treatment
gases:
Chlorine
Carbon dioxide
Ammonia
Sulphur dioxide
(for other gases consult)
The gas feed systemsV10k automatic and manual
control is the proven gas feed technology from
Wallace & Tiernan for capacities up to 15 kg/h
combining a standardised flexible design with
user-selectable configurations. The V10k gas
feeders operate according the indirect procedure
i.e. operating under a vacuum that is produced at
the injector where the metered gas (e.g. chlorine
gas) is dissolved in the operating water and the
resultant solution is discharged to the point of
application. Gas flow control is achieved by the
proven Wallace & Tiernan V-notch ensuring the
well-known accuracy and repeatability.
METHOD OF OPERATION
The V10k gas feed systems operate under a
vacuum that is produced at the injector and
transmitted through the control unit to the pressure/
vacuum regulating valve on the gas supply source.
This diaphragm-operated valve is opened by the
vacuum and allows the gas to flow to the control
unit where it passes through the rotameter and the
V-notch orifice. On the rotameter the gas flow rate
is measured and indicated. Downstream of the
V-notch orifice the gas passes the differential
regulating valve which maintains a consistent feed
rate regardless of changes in the operating vacuum.
At the injector, the metered gas is dissolved in the
operating water stream and discharged as solution
to the point of application.
Highest Safety by Remote Vacuum
The remote vacuum principle (vacuum from the gas
supply containers up to the injector) is the basic
technology of this design. There are no gas lines
under pressure. If any part after the supply container
gets broken, no gas can leak out, but air will leak in.
Therefore the remote vacuum technology stands for
the highest safety level in gas feed systems.
V-notch for Precise Gas Flow Control
The V-notch control orifice, field proven in hundreds
of thousands of installations around the world,
provides reliable, consistent gas feed at any
capacity. It consists of a precision-grooved plug that
slides through an annular seat. Any position of the
plug in the seat results in a specific orifice size and a
corresponding feed rate. This results in accurate gas
flow control and excellent repeatability.
Due to their size and the configuration of the orifice,
theV10k systems are resistant against fouling from
contaminants in the gas supply.
Control of the gas feed rate for the V10k manual
control gas feed system is achieved manually by
turning the adjustment knob, for theV10k automatic
control gas feed system either manually or auto-
matically via an electric positioner.
Electric Positioner for Automatic control
For automatic control, the V-notch plug is moved
depending on the application requirements:
Manual override is achieved by simply pulling the
knob to disengage the drive motor
3 sets of volt-free contacts for system control:
manual override
MAX position
MIN position
Feedback potentiometer for precise operation
with the SCU or PCU-fuzzycontrollers
4 20 mA actuator control (optional)
Simple ratio control
Feed rate adjustment by means of a dosing factor
Connection to SPS control systems
TI 25.100DE
www.wallace-tiernan.com
WALLACE & TIERNAN
V10k automatic
8/13/2019 V10k Auto Manu TI25100DE
2/2
Due to continual product development and improvement,
certain specifications may change without prior announcement.
WALLACE & TIERNAN
Australia
WALLACE & TIERNAN Pty Limited
Level 1, 6 10 Talavera Road
North Ryde, NSW 2113, AUSTRALIA
Tel.: +61 2 9850 2800, Fax: +61 2 9850 2801Email: [email protected]
Canada
U.S. FILTER / WALLACE & TIERNAN
250 Royal Crest Court
Markham, Ontario L3R 3S1, CANADA
Tel.: +1 905 944-2800, Fax: +1 905 474-1660
France
WALLACE & TIERNAN S.A.R.L.
BP 150, 1/3 rue Pavlov
F-78196 Trappes Cedex, FRANCE
Tel.: +33 1-34 82 18 50, Fax: +33 1-30 50 98 08
Email: [email protected]
Germany
WALLACE & TIERNAN GmbH
Auf der Weide 10
D-89312 Gnzburg, GERMANY
Tel.: +49 8221-9040, Fax: +49 8221-904203
Email: [email protected]
Mexico
U.S. FILTER Chem Feed Mexico SA De CV
Via Jose Lopez Portillo 321
Tultitlan, Edo. Mex., 54900 MEXICO
Tel.: +52 55 2159-2959, Fax: +52 55 2159-2985Email: [email protected]
Romania
WALLACE & TIERNAN Romania srl.
Str. Liviu Rebreanu nr. 6
Bl B1 Sc. A, ap. 39, Sector 3, Bucuresti, ROMANIA
Tel.: +40 21-3046011, Fax: +40 21-3046012
Email: [email protected]
United Kingdom
WALLACE & TIERNAN
Priory Works, Tonbridge
Kent TN11 0QL, ENGLAND
Tel.: +44 1732-771777, Fax: +44 1732-771800Email: [email protected]
USA
U.S. FILTER / WALLACE & TIERNAN Products
1901 West Garden Road
Vineland, NJ 08360, USA
Tel.: +1 856-507-9000, Fax: +1 856-507-4125
Represented by:
TECHNICAL DATATI 050.400-10DD
Gases and Scale Capacities:
Chlorine: up to 15.0 kg/h
Carbon dioxide: up to 8.0 kg/hSulphur dioxide: up to 10.0 kg/h
Ammonia: up to 5.0 kg/h
Feed Ranges:
e.g. chlorine gas
1 22.5 g/h 0.15 3.0 kg/h
3 60.5 g/h 0.20 4.0 kg/h
10 200.5 g/h 0.25 5.0 kg/h
20 400.5 g/h 0.30 6.0 kg/h
30 600.5 g/h 0.40 8.0 kg/h
50 1000.5 g/h 0.50 10.0 kg/h
75 1500.5 g/h 10.00 15.0 kg/h
100 2000.5 g/h
Operating Range (V10k automatic control):
1: 20 for any rotameter
Accuracy:
4 % of F. S.
Operating Temperature:
+10C to +50 C
Operating Vacuum:
40200 mbar
Operating Water Pressure at Injector:
max. 21 bar at 20 C
max. 13 bar at 30 C
max. 10 bar at 40 C
max. 5.9 bar at 50C
4 20 mA actuator control (optional)
Measurement Inputs:
1 x 4 20 mA
1 x servo motor position feedback
1 x external dosing factor
Relay Outputs:
2 x non-isolated
Power Supply:
115/230 V AC, 50 60 Hz
Power Supply (V10k automatic control):
0.25 A at 230 V AC
0.50 A at 115 V ACElectric Positioner (V10k automatic control):
Operating voltages: 230 V 115 V
50/60 HZ 50/60 Hz
Rating: 19 mA 46 mA
Time for 0100% move: 80 sec. 66 sec.
Potentiometer: 1 kOhm 10 %
Max. switching capacity: 1250 VA 150 W
Enclosure: IP 67
Available Configurations:
with 5 rotameter (standard) or 10 rotameter
4 kg/h, 10 kg/h vacuum regulator or
higher capacities standard or with switch-over option
injector size 1/3, 1 or 2
standard or anti-siphon type
Option:
Vacuum contact pressure gauge for installation into the gas
supply line for monitoring operating vacuum
Dimensions:
V10k automatic control incl. panel (W x H x D):
with electric positioner: 369 x 880 x 185 mm
with electric positioner and controller 580 x 880 x 185 mm
V10k manual control:
350 x 380 x 150 mm
Weight:
V10k automatic control with electric positioner 15 kg
V10k automatic control with electric positioner
and controller 20 kg
V10k manual control 5 kg
2/2005
TI 25.100DE
V10k manual