17
Welcome 欢欢 Using the PCC 欢欢 PCC Dipl.-Ing. Manfred Schleicher

Welcome 欢迎

Embed Size (px)

DESCRIPTION

Welcome 欢迎. Using the PCC 使用 PCC Dipl.-Ing. Manfred Schleicher. PCC enables to transfer recorded data from JUMO paperless recorders JUMO controllers with registration function PCC 可用来从久茂无纸记录仪,久茂带记录功能的控制器传递记录数据 … and provides this data in an archive data file 并在一个存档文件提供这数据 - PowerPoint PPT Presentation

Citation preview

Welcome 欢迎

Using the PCC 使用 PCC

Dipl.-Ing. Manfred Schleicher

2Using the PCC/ Manfred Schleicher (2012-01-03) 2

• PCC enables to transfer recorded data from

• JUMO paperless recorders

• JUMO controllers with registration function

PCC 可用来从久茂无纸记录仪,久茂带记录功能的控制器传递记录数据

… and provides this data in an archive data file

并在一个存档文件提供这数据

• This presentation exemplifies how to set the data transfer for

a paperless recorder LOGOSCREEN nt via ETHERNET

此演示示例如何对一台无纸记录仪提供以太网设置数据传输

3Using the PCC/ Manfred Schleicher (2012-01-03) 3

PCC connection paperless recordersPCC 所连无纸记录仪

LOGOSCREEN 500 cf LOGOSCREEN nt

LOGOSCREEN cf / es

4Using the PCC/ Manfred Schleicher (2012-01-03) 4

PCC connection controllersPCC 所连控制器

IMAGO F3000 IMAGO 500

5Using the PCC/ Manfred Schleicher (2012-01-03) 5

Transfer possibilities 传输的可能

• There are four possibilities to transfer data有4种可能来传递数据 ETHERNET以太网 RS interface串口 MODEM connection调制解调器连接 PC interface and USB interface (LOGOSCREEN nt)

电脑接口和USB接口(LSnt)

6Using the PCC/ Manfred Schleicher (2012-01-03) 6

LS nt via ETHERNET 通过以太网的数据传输• In defined time intervals the PCC accesses the device

在定义的时间段PCC进入设备• The software analyses which data are recorded in the device and which are stored in the archive 软件分析记录在仪器哪些在存档文件中• Data which are not in the archive are transferred to the archive and stored 哪些数据不

IP address 10. 10. 90. 41

Sub net mask: 255. 255. 0. 0

Gateway: 10. 10. 0. 1

LO

GO

SC

RE

EN

nt

7Using the PCC/ Manfred Schleicher (2012-01-03) 7

Data to be read 要读取的数据• Read data are marked in the paperless recorder

• The memory capacity is defined as free memory

• The free memory is displayed at the front of the device

• With factory setting the displayed free memory refers to the readout via CF card

• When working with PCC the shown free memory should refer to the interface. The following setting has to be executed:

8Using the PCC/ Manfred Schleicher (2012-01-03) 8

Device lis 设备清单 t• Devices from which data are transferred have to be entered in the

device list

9Using the PCC/ Manfred Schleicher (2012-01-03) 9

Define LOGOSCREEN nt 定义 nt• Create a new device, define LOGOSCREEN nt

• Define communication Setup or ring memory via TCP/IP

10Using the PCC/ Manfred Schleicher (2012-01-03) 10

• The IP address of the recorder has to be entered.

IP-addressIP- 地址

11Using the PCC/ Manfred Schleicher (2012-01-03) 11

• Select the archive (s) in which the date have to be stored

• In our example the data are stored in two different archives (one on

the hard disc in the PC and one on a server)

Archive

12Using the PCC/ Manfred Schleicher (2012-01-03) 12

Time settings

• Time intervals for data transfer

13Using the PCC/ Manfred Schleicher (2012-01-03) 13

The device listDefine LOGOSCREEN nt

• In the menu “time settings” you can define a time synchronization

• In our example at 6:00 a.m. the device time of the paperless recorder

is synchronized with the time of the PC to which the paperless

recorder is connected. (The assumption is that the time of the

paperless recorder has a time deviation less than 30 sec to the time of

the PC.)

14Using the PCC/ Manfred Schleicher (2012-01-03) 14

Automatic modeStart automatic transfer

• After start of the automatic mode the data of the devices are

automatically collected every 2 hours

• The status of the transfer is displayed

15Using the PCC/ Manfred Schleicher (2012-01-03) 15

Archive

• The archives are available an can be opened with the PCA3000

software

16Using the PCC/ Manfred Schleicher (2012-01-03) 16

Automatic in background• With the function “automatic in background” the software is only

shown as a little symbol. But it is active.

• After restart of the PC, the PCC starts automatically and works in the

background

• With double click on the software is shown again

Thank you for your attention.