1/45
rvic M nual
Wall split type
7/22/2019 20115272209
2/45
Table of Con tents
1. Summary .............................................. .3
2. Model explaining .............................................. .4
3. Use and installation ............................... .4
4. Exploded view and part list.............................................. 20
5. Operation principle. ................................................ 28
6. Parameter................................................. 28
7. Wiring diagrams. .................................................. 30
8. PCB principle chart................................................. 32
9. Part list of PCB ..................................................... 32
10. PCB function . .......................................... 34
11. Troubleshooting. ........................... 40
7/22/2019 20115272209
3/45
1. Summary
1.1indoor unit
Model 48
1.2outdoor unit
9000BTU 12000BTU
model CQS-25H3A-G48AY1 CQS-35H3A-A48AH1
indoor unit 790270180 790270180
Net Dimension
outdoor unit 700225500 795255540
7/22/2019 20115272209
4/45
2Model explainingc
Improve an ordinal number
Divide the body outdoors box a body code
External appearance characteristic code
Separately the body indoor machine(or whole type) style code
Code of refrigerant typeno code - R22C-R407cA-R410a
Power type1:115v/60Hz 2:220V/60Hz3:220-240V/
50Hz4:240V/50Hz
Main function code: c-Cold breeze type;H-Hot pump type;A-Hot
pump the type take assistance electricity to heat;E-The electricity
heat
Capacity code: x1000W
Separately the body pit code inside the indoor machine(or whole
type)
Structure form code
Special craft code:Q-Deal with contact quickly;S-Soft start;d-
Outside tube in addition to frost
The weather type code(T1 type code abridge)
"C" CHIGO brand
as: CQS-25H3A-G48AY1
T1 climate type,deal with contact quickly ,hot pump type, wall split type air conditioner, cooling capacity
is 2500Wpower is 220-240V/50Hz/1PHrefrigeration is R410A,the kernel of indoor unit is 418the pattern
no. is 48first time design, outdoor unit is 1HP of 2003 year
Indoor unit modle isCQS-25H3A-G48Aoutdoor unit model isCQS-25H3A-Y1
3. Use and installation .
BASIC ACCESSORIES
This Installation section explains how and where to connect this new air conditioner. Please read make sure
all accessories are included as shown below and read manual thoroughly. This Installation section is provided
to assist the per-son knowledgeable in air conditioner installation and should not be installed by anybody
who is not thoroughly familiar with this type of installation. Please contact a professional installer if
necessary.
ACCESSORIES SUPPLIED WITH THE UNIT:
No Part Name Q'ty Remark No Part Name Q'ty Remark
1 Remote Controller 1 3 Battery 2
2 Remote Holder 1
7/22/2019 20115272209
5/45
7/22/2019 20115272209
6/45
7/22/2019 20115272209
7/45
7/22/2019 20115272209
8/45
7/22/2019 20115272209
9/45
7/22/2019 20115272209
10/45
7/22/2019 20115272209
11/45
7/22/2019 20115272209
12/45
7/22/2019 20115272209
13/45
Before installation:
Selection of installation positions for indoor unit
To be installed at the position where the air delivered from the unit can reach every corner of the room
Avoid to biockage the air inlet or outlet of the indoor nit
To avoid too much oil smoke or steam
Avoid possible generation infiow, lingering or leakage of flamm gasee
Avoid high-frequency facilities (such as high frequency arc welders etc.)Not to install a fire alarm near the air outlet.
To avoid the places where acid solutions are frequently used
[Selection of installation positions for indoor unit]
To be installed at the position where the air delivered from the unit can reach every comer of the room;
To avoid being affected by the outdoor air;
To avoid blockage to the air inlet or outlet of the unit;
To avoid too much oil smoke or steam;
To avoid possible generation,inflow,lingering or leakage of flammable gases;
To avoid high-frequency facilities(such as high frequency arc welders,etc,)
To avoid the places where acid solutions are frequenty used;
To avoid the places where some special sprayers(sulfides) are frequently used
Not to install on top of the musical instruments,TV,computer etc,valuable appliance.
Not to install a fore alarmning device near the air outlet of the unit(during operation,the fire alarm device might be
erroneously triggered by the warm air from the unit);
Make sure of enough space for installation and maintenance To take into consideration the operational convenience and safety in installation,it is recommended ti ensure enough
space between the unit and the walls,
Attention:lf there are some additional function devices to install on the air conditioner,Besure add
to the installation space for the function devices
Height limits of indoor and outdoor units Either the indoor unit or the outdoor unit can be higher,but the height difference must comply the stated
requirements Try to reduce the bending of the piping line as much as possible so as to avoid possidle negative impacts
upon the performnances of the units
7/22/2019 20115272209
14/45
[Selection of installation positions rot outdoor unit]
To install the outdoor unit at the places which can stand the load of the machine weight and will
not cause big vibrations and noises;
To install the unit at the places not to exposed to rain or direct sunshine,and the places with
good ventilation;
The noises generated from the unit will not affect the neighboring places;
Do not install the unit on non-metal frame;
Not to install the unit at the places where there might occur the generation,inflow,stay or leakage
of inflammable gases;
pay attention to the drainage of the condensed water from the base plate during operations;
To avoid the air outlet being directly against the wind.
Detailed space requirements around the outdoor unit
[lnstallation fixture of indoor unit]
7/22/2019 20115272209
15/45
7/22/2019 20115272209
16/45
7/22/2019 20115272209
17/45
7/22/2019 20115272209
18/45
7/22/2019 20115272209
19/45
7/22/2019 20115272209
20/45
4Indoor outside explosion the diagram and spare parts catalogue4.1 CQS-25H3A-G48AY14.1.1 Explosive view of indoor unit
4.1.2 Spare parts list of indoor unitPart No. Qty
No. DescriptionCQS-25H3A-G48AY1
1 Louver 100420003/100420083 2
2 Outlet part 391200006 1
3 Left angle plate 100360001 1
4 Base 100060106 1
5 Cross flow fan 100010016 1
6 Fan Bearing 110010603 1
7 Connecting Cable 342300055 18 Quick coonector 979900183 1
9 Evaporator assembly 972900618 1
10 Evaporator left fixed plate 109990108 1
7/22/2019 20115272209
21/45
11 Screw cover 109990023 2
12 Middle frame 391070007 1
13 Air Filter 100190111 2
14 Display box cover . 1
15 Disp;ay box 100410004 1
16 Front Panel 391022065 1
17 Remote controller 336815006 1
18 Roomtemp.Sensor Holder 100280105 1
19 Pipe Clamp 100430025 1
20 Eliminator 100420002 1
21 Evapora torright fixed plate 109990109 1
22 Motor platen 100130003 1
23 Motor 030020173 1
24 Wire Clip 391110017 1
25 Power Cord 050010042 1
26 Terminal Board 030090005 127 Display lamp panel 331800039 1
28 Tube Temp.Sensor 079990030 1
29 Electric control plate 331300107 1
30 Room Temp.Sensor 049990012 1
31 Electric box 100100035 1
32 Transformer 030180061 1
33 Connecting Wire 120310028 1
34 Base right angle plate 100300003 1
35 Wall-mounting frame 020100010 136 Step motor 320273001 1
37 Step Motor plate 320273001 1
38 Crank connecting rod 100420082 1
7/22/2019 20115272209
22/45
4.1.3 Explosive view of outdoor unit for 1HP
4.1.4 Spare parts list of outdoor unitPart No. Qty
No. DescriptionCQS-25H3A-G48AY1
1 Front Grill 020120002 1
2 Grill Clip 109990256 8
7/22/2019 20115272209
23/45
3 Front Plate 020070001 1
4 Small handle 100050001 1
5 Nut 150020009 1
6 Gasket 150030013 1
7 Axial flow fan 100030013 1
8 Motor 030020201 1
9 Motor support 313040004 1
10 PE Sponge PE 090020234 1
11 Base 020010129 1
12Anti-vibration pad for the
compressor 010011455 3
13 Compressor 302114004 1
14 Nut 010011578 1
15 Gasket 010011456 3
16 Nut 150020003 1
17 Top panel 020080001 1
18 PU Sponge 090020226 1
19 Partition board 020030001 1
20 Electric installation board 020130006 1
21 Compressor Capacitor 030010015 1
22 Capacitor Clamp 020140006 1
23 Fan Capacitor 030010005 1
24 Terminal Board 030090025 1
25 Wire Clip 321100011 1
26 PU Sponge 090020227 1
27 Condenser 372100103 1
28 tube temp. sensor wire 338000008 1
29 Copper pipe or sensor 079990030 1
30 Capillary Assy 971900314 1
31 Damping rubber 110030023 1
32 Drainpipe for the condensor 360510003 1
33Intake pipe for the
condensor 360440093 1
34 4-way Valve 973500175 1
35 Discharge pipe 360220111 1
36 Damping block 110020011 1
37 Damping rubber 110030017 2
38 Suction pipe 360120107 1
39 Quick connector 1 1 351600014 1
40 Quick connector 2 2 351600014 1
41Low-pressure Connecting
Pipe 979900184 1
42High-pressure Connecting
Pipe
361300062 1
43 Filling valve 359000004 1
44 Valve installation plate 313020016 1
45 Large handle 100040001 1
7/22/2019 20115272209
24/45
46 Right panel 313060035 1
47 Connecting Wire 425300038 1
48 Connecting Cable 342300046 1
49 Electric heater 320440005 1
50 Electric heating wire clip 313990014 4
4.2 CQS-35H3A-A48AH1
4.2.1 Explosive view of indoor unit
4.2.2 Spare parts list of indoor unitPart No.
No. DescriptionCQS-35H3A-A48AH1
Qty
1 Louver A 100420003 1
2 Louver B 100420083 1
3 Swing Louver 100420007 12
4 Connecting rod 100420072 3
5 Guide Louver Bearing 100420008 6
6 Outlet part 100090110 1
7/22/2019 20115272209
25/45
7 Left angle plate 100360001 1
8 Base 100060108 1
9 Cross flow fan 100010016 1
10 Cross flow fan bearing 1
11 Fan Bearing 110010603
1
12 Connecting Cable 342300097 1
13 Quick connector 979900178 1
14 Evaporator assembly 972901480 1
15 Evaporator left fixed plate 109990108 1
16 Remote controller 336815006 1
17 Screw cover 109990023 2
18 Middle frame 391070007 1
19 Front Clip 391220004 4
20 Air Filter 100190127 2
21 Cold Catalyst 119990011 1
22 Display box cover
100410004 123 Display box 100410004 1
24 Front Panel 391022065 1
25 Middle frame coverplate 100080034 1
26 Room temp. Sensor Holder 100280105 1
27 Insert Block 079990240 1
28 Copper pipe of sensor 079990030 1
29 Pipe Clamp 100430025 1
30 Evaporator right fixed plate 109990109 1
31 Motor platen 100130003 1
32 Motor 030020173 1
33 Electric box cover 100100041 1
34 Display lamp plate 331800039 1
35 Tube Temp. Sensor 079990030 1
36 Room Temp. Sensor 049990012 1
37 Electric control plate 331300009 1
38 Connecting Wire 425300063 1
39 Transformer 030180061 1
40 Electric box 100100035 1
41 Wire Clip 391110018 1
42 Terminal Board 030090005 1
43 Power Cord 050010050 1
44 Right angle plate 100300003 1
45 Wall-mounting frame 020100010 1
46 Screw 150010019 2
47 Step motor 320273001 1
48 Motor fixed plate 100420002 1
49 Crank connecting rod 100420082 1
50 Upper crank 100420001 1
51 Lower crank 100420081 1
52 Thermal insulation pipe 099990080 1
7/22/2019 20115272209
26/45
4.2.3 Explosive view of outdoor unit for1.5HP
4.2.4 Spare parts list of outdoor unitPart No. Qty
No. DescriptionCQS-35H3A-A48AH1
1 Front Grill 020120015 1
2 Grill Clip 109990256 8
7/22/2019 20115272209
27/45
3 Front Plate 020070056 1
4 Small handle 100050021 1
5 Nut 150020009 1
6 Gasket 150030018 1
7 Axial flow fan 393010001 1
8 Motor 320222005 1
9 Motor support 313040002 1
10 PE Sponge PE 090020234 1
11 Base 313011093 1
12Anti-vibration pad for the
compressor 305146005 3
13 Compressor 302114009 1
14 Gasket 305142002 3
15 Nut 305143002 3
16 Top panel 020080002 1
17 Partition board 313030014 1
18 PU Sponge 090020027 1
19 Electric installation board 020130006 1
20 Compressor Capacitor 030010017 1
21 Capacitor Clamp 020140006 1
22 Terminal Board 321000025 1
23 Fan Capacitor 030010005 1
24 Wire Clip 321100003 1
25 PU Sponge 090020028 1
26 Condenser 372100086 1
27 Tube temp.sensor wire 338000008 1
28 Copper pipe or sensor 079990030 1
29 4-way Valve 973500062 1
30Intake pipe for the
condensor 360450021 1
31 Capillary Assy 971900295 1
32 Damping rubber 110030017 1
33 Filter 361910002 1
34 Right panel 020060041 1
35 Large handle 100040002 1
36 Quick connector 1 1 351600014 1
37 Quick connector 2 2 351600014 1
38 Connecting Cable 342300045 1
39Low-pressure Connecting
Pipe 979900176 1
40High-pressure Connecting
Pipe 361300062 1
41 Filling valve 359000004 1
42 Valve installation plate 020020008 143 Drainpipe for the condensor 360540042 1
44 Discharge pipe 360220103 1
45 Damping block 110020011 1
7/22/2019 20115272209
28/45
46 Suction pipe 360130149 1
47 Damping rubber 110030023 2
48 Connecting Wire 425300038 1
49 Electric heater 320440005 1
50 Electric heating wire 313990014 4
5. Operation principle
outdoor unit
outdoor fan
1
14
13
215
connection pipe12
coolingpay attention to sealing
heating
163
4
5
7
8
6
indoor fan
1011
9
indoor unit
connection pipe
1.compressor 2. 4-way value 3.condenser 4.flow divider for condenser 5.Non-return valve 6.auxiliary capillary
7.cooling capillary 8.high-pressure valve 9.flow divider for evaporator 10.evaporator 11. pipe temp. sensor for
evaporator 12.low-pressure valve 13.Vapor liquid separator 14.low-pressure switch 15. high-pressure switch 16pipe
temp. sensor for condenser
Cooling cycly compressor4-way valuecondenserflow divider for condenserNon-return valvecooling capillary
high-pressure valveflow divider for evaporatorevaporatorlow-pressure valve4-way valueVapor liquid separator
compressor.
Heating cyclycompressor4-way valuelow-pressure valveevaporatorflow divider for evaporatorhigh-pressure valve
cooling capillaryauxiliary capillaryflow divider for condensercondenser4-way valueVapor liquid separator
compressor.
NoteTo the model of RF or LF beginning, use outdoor unit model to express the whole unit.
6. Parameter Performance parameter
Model CQS-25H3A-G48AY1 CQS-35H3A-A48AH1Apattern NO. 48 48
Power supply Ph-V-Hz 220-240V/50Hz 220-240V/50Hz
Cooling Cooling capacity W 2780 3590
7/22/2019 20115272209
29/45
Cooling Input W 865 1120
Cooling Rated current A 4.0 5.1
EER w/w. 3.21 3.21
Heating Capacity W 2780 3680
Heating Input W 770 1020
Heating Rated current A 3.5 4.7Heating
COP w/w. 3.61 3.61
Max. input consumption W 1660 2170
Max. current A 8.2 10.6
Model PA108X1C-4DZDE PA140X2C-4FT
Type ROTARY ROTARY
Brand TOSHIBA TOSHIBA
Capacity W 2570/2670 3365/3385
Input W 885/915 1160/1200
Start electric current A 21.7 2601
Thermal protector inner inner
Compressor
Capacitor uF 25 35
Model YDK-16-4 YDK-16-4
Input W 47 47
Capacitor uF 1.2 1.2Fan motor
Speed r/min 1350 1350
Fan motor diameterheight mm 93633 93633
Air flow m3/h 500 600
Noise level dB(A) 29-39 35-42
Net Dimension (W*H*D) mm 790*270*180 790*270*180
Packing Dimension (W*H*D) mm 875*345*340 875*345*340
Indoorunit
Net/Gross weight Kg 12/14 12/14
Model YDK-30-6 YDK-35-6A H
Input W 85 67
Capacitor uF 2 2Fan motor
Speed r/min 890 900
Fan motor diameterheight mm 384136 401115
Noise level dB(A) 49 54
Net Dimension (W*H*D) mm 700*225*500 795*255*540
Packing Dimension (W*H*D) mm 825320535 920*335*585
Net/Gross weight Kg 30/32 36/40
Outdooruni
Refrigerant type g R410A/610g R410A/1020g
7/22/2019 20115272209
30/45
7.Wiring diagrams
7.1 CQS-25H3A-G48AY1
Indoor unit:
Outdoor unit:
7/22/2019 20115272209
31/45
7.2CQS-35H3A-A48AH1
Indoor unit:
Outdoor unit:
7/22/2019 20115272209
32/45
7/22/2019 20115272209
33/45
A15 0101702601 10K RT-1/4W 9
R3R16R17R19
R22R23R25R31
R48
A16 0101701201 330 RT-1/4W 1 R14
A17 0101701401 510 RT-1/4W 2 R49R52
A180101102201 4.3K RJ-1/4W 2 R18R20
A19 0101701901 R carbon film 2 K RT-1/4W 2 R4R37
A20 0101701301 R carbon film 390 RT-1/4W 1 R35
A21 0101703401 R carbon film 300 K RT-1/4W 1 R15
A22 0101200503R oxidation film
220 RY-1W 1 R36
A23 0101701001R carbon film
220 RT-1/4W 2 R50R51
A24 01042002021.2F5%CBB61
450VAC1 CFI
A25 0104300201 473/275V 1 C20A26 0104300301 104/275V 2 C21C22
A27 0104600811 102 8C3C4C11C12
C15C16C19C25
A28 0104601311 104 10C1C2C5-C9C13
C17C26
A29 0104101102 1000F/35V 1 E7
A30 0104101001 220F/16V 1 E2
A31 0104100401
capacitance
10uF/25V 1 E5
A320701100201 XH-2A white 1 CNC
A33 0701100301 XH-3A white 1 CNW
A340701100302
XH-3A
yellow 1 CND
A35 0701100501 XH-5A white 1 CNM
A36 0701100401 XH-4A white 1 CNG
0701100601 XH-6A white 1 CNEA37
0701200301 VH-3A white 1 CNB
A38 0701200401 VH-5A white 1 CNU
A39 1501300600
connector
XH-2A white 1 CNC
A401501300600
Compressor
relay HF2160-1A-12DE1 52C
A41 2104000100 safety clip 520mm 2 FUSE
A42 0116100100
I nsur ance
t ube 3.15A/250AC 1 FUSE
A43 9803010400 safety ZGAY/621-10-126 1 ZR
A44 0304200500Si ngl e- I nt er
cal at i on 6.3 KET 1 N2
7/22/2019 20115272209
34/45
A45 2903300103 jumper 0.510mm 9 J1-J6J8-J10
A46 0125300100 inductance 0.043mH 1 L1
A47 0119200601 button A06-(c)9.5mm 1 SW1
A48 1303000211 transformer B03-01A
A49 1102101680 jumperJF1DJ46/48DCP21
2-Q
1
156 113.5 B items cooling and hot plate materialsB01 0107701301 diode IN4148 2 D6D9
B02 1501200400 relay JZC-32F 12V 2 X3X1
B03 2903300103 jumper 0.510mm 1 J7
B04 0304200500Si ngl e- I nt er
cal at i on6.3 KET 2 20SFMO
B05 0107100201 audi on 9013 1 Q2
B06 0101702201resistance
47K RT-1/4W 1R13
C items Electric heating materialsC01 diode IN4148 3 D6D9D10
C02 relay JZC-8F 12V 2 X1X3
C03 relay SJ-S-112DM 1 X210A/250VAC
10A/250VAC
C04 jumper 0.510mm 1 J7
C05
Si ngl e- I nt er cal at ion
6.3 KET 2 20SFMO
C06Si ngl e- I nt er cal at ion
4.8 1 HEAT
C07 audion 9013 1 Q2
C08 resistance 4.7K RT-1/4W 1 R13
D items Bl ackout memory mat er i al sD01 0107501000 Mani f ol d AT24C02 1 IC7
D02 0104601311 capacitance 104 1 C18
E items Ani on mat er i al sE01 0304200500
Singer-zntercalation
6.3 KET 1 N1
10 PCB function:NOTE: Ts is the set temperature, Tr is indoor room temperature, TP1 is indoor coil pipe temperature, TP2 is outdoor coil pipe
temperature.
Display panelLED
according to display mode: dehumidification, cooling, ventilation, heating, auto, sleep, fan speed, swing, timer, indoor
7/22/2019 20115272209
35/45
fan running.
wind speed indication correspond fan speed of indoor blower fan.
Cooling
Start up the compressor: when the room temperature is more than Ts+1, compressor start-up
Shut down the compressor: when the room temperature is less than or equal to the set temperature Ts-1,
compressor shutdown
When the temperature of coil pipe of the indoor units is less than or equal to 1 for one minute and the
compressor has continuous run for more than ten minutes, the compressor and outdoor blower fan shut down
through the electric control board and the indoor blower fan is running at low speed.
When the temperature of coil pipe of the indoor units is more than or equal to 7 and the compressor has
shutdown for more than three minutes, the compressor and outdoor blower fan start to run and the indoor blower
fan is running at set speed.
When the temperature of coil pipe of the indoor units is equal to or less than 10 for three minutes in the
compressor has continuous run for three minutes, the compressor, indoor and outdoor blower fans and swinging
wind shut down. Restart up six minutes later; if the above situations appear again within six minutes, all the
outputs are shut down through the electric control board and display failure.
After the compressor runs five minutes, the lamp flashes 4 times per six seconds or display E4 if the temperature
of indoor coil pips is more than 25 in the continuous 20 minutes. The controller will automatically shut down if
the temperature of indoor coil pips is more than 25 in another continuous 20 minutes, that is the abnormality
protection of outdoor units and the indicator lamp keeps its former state of flashing. If the temperature of indoor
coil pips is less than 25 in the second 20 minutes or the compressor shuts down, the electric control board willstore to the normal display and the time is restarted when starting up the compressor next time.
Heating (only applicable to heat pump units)
Start up the compressor: when the room temperature is less than Ts-1, compressor start-up
Shut down the compressor: when the room temperature is more than or equal to the set temperature Ts+3,
compressor shutdown
The electric heating start-up in the heating mode shall meet the following conditions: start up the compressor
and indoor blower fan none defrost TP1< 49 Tr 20.
The electric heating shutdown in the heating mode shall meet one of the following conditions: shutdown
indoor blower fan Tr 23 TP150.
7/22/2019 20115272209
36/45
In the heating mode, the indoor flower fan can be set as high/ medium/ low /automatic running mode by remote
control. however the anti cool air function is prior. In the heating mode, the anti cool air control function is to
control shutdown of the indoor blower fan by detecting the temperature of coil pipe of evaporator so as to attain
the purpose of preventing cold air from blowing.
For the waste heat emission function in the heating mode, in principle, the indoor blower fan shall be on for
fifteen seconds after the electric heating is closed.
When the temperature of coil pipe of indoor units is more than or equal to 56, the outdoor blower fan shuts
down and it enters the overload protection; when the temperature of coil pipe of indoor units is less than or equal
to 52, the outdoor blower fan starts up and it exit the overload protection.
When the temperature of coil pipe of indoor units rises to 63, the compressor and outdoor blower fan are closed
and two minutes later, the change valve is closed. The indoor blower fan is running at the set speed. Restart up six
minutes later; if the above situations appear again within ten minutes, all the outputs are shut down through the
electric control board and display failure.
When you press turbo button of remote, the air conditioner enter turbo running, compressor ,outdoor blower fan
and four-way valve turn on all along, indoor blower fan run at high speed and it must meet start condition, turbo
indication is light.
After the compressor runs five minutes, the lamp flashes 4 times per six seconds or display E4 if the temperature
of indoor coil pips is less than 30 (heating) in the continuous 20 minutes. The controller will automatically shut
down if the temperature of indoor coil pips is less than 30 in another continuous 20 minutes, that is the
abnormality protection of outdoor units and the indicator lamp keeps its former state of flashing.
Defrost (only applicable to the heating mode)
1. the intelligent defrost
In the heating mode, the electric control board checks and compares the temperature of indoor room and indoor coil
pipe after the compressor works for a while; judge whether the outdoor heat exchanger part is frosted or not according to
conditions such as the change of indoor coil pipe temperature; if it is judged as frosted, it automatically enters defrosting
process. When defrosting, close the indoor and outdoor blower fan and four-way valve.
2. Outdoor PCB for defrost.
In the heating mode, the unit defrost by outdoor control board
unit start defrost shall all meet the following conditions
acompressor continuous running over 7 minutes
bdefrost relay shut off-5
ccompressor cumulate running time over 50 minutes.
first defrost interval time is 50 minutes, later defrost interval time decided by last defrost time.
Defrost time(minute) Next defrost interval time(minute)
15 30
10--15 40
7--10 60
3--7 70
3 802end defrost condition(meet one of follows)
adefrost time have fifteen minutes.
bdefrost relay turn on8
7/22/2019 20115272209
37/45
cpress ON/OFF key in defrost process.
3. Outdoor sensor for defrost
unit start defrost shall meet one of the following conditions
a. compressor cumulate running time over 30 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than 15 for one minutes (Tp2-15).
b. compressor cumulate running time over 40 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than 5 for one minutes (Tp2-15).c. Air conditioner first power on or it wait over 30 minutes ,the temperature of coil pipe of the outdoor units is
equal to or less than 2 (Tp2-15)
end defrost condition(meet one of follows)
a. the temperature of coil pipe of the outdoor units is more than 15 (Tp2-15).
b. defrost time have fifteen minutes.
Sequence chart in defrosting mode
Dehumidification
Dehumidification running is to eliminate the water vapor in the air by using the cool circulating capacity, but the
dehumidification will not decrease the indoor temperature in great deal. The air conditioner automatically repeats on
and off circulation according the room temperature, which is shown in the following figure.
indoorblower fan
C
C
door
blower fan
Tr
shutdown shutdownshutdown shutdown shutdown
shutdownshutdownshutdownshutdownshutdown
low speed
Tr10
shutdown
start-up
start-up start-up
start-up start-up
start-up start-up
start-up
forbiddehumidify
In the dehumidification mode, the indoor fan is running at the low speed for twenty seconds at first, then it select
working mode.
Automatic mode
Conditions for entering the automatic running mode are: After power-up for the first time, start up and select the
automatic operating mode of remote or press emergency key, the working mode depends on Tr and if the working
mode had set , it doesnt change by Tr and the default set temperature is 25 .
7/22/2019 20115272209
38/45
25
Tr
21
26 C
mode
Time on and time off
When the time on or time off is used, the clock of remote controller shall be corresponding to the current clock and the
timing times is less than or equal to 24 hours, when the timing time is reached, unit will start-up or shutdown.
Sleep functionWhen the sleep key is press, air conditioner enter sleep state, indoor blower fan running at low speed, only sleepindication display.
Emergency key function
There is a forcible execution key on the panel of indoor units and the air conditioner can run by pressing the key when
the remote control is out of work or missing.
When pressing down the forcible execution key, then power up and enter the self-check program.
7/22/2019 20115272209
39/45
Failure display
Display state
LEDserial failure
Running lamp Timer lampLCD
Indoor unit
1 Indoor TEMP. sensor failure Flash 1 time/8 SEC light E2
2 Indoor coil pipe TEMP. sensor failure Flash 2 time/8 SEClight
E3
3 Overheat (frost) protection Flash 3 time/8 SEClight
E8
4 Pump failure Flash 4 time/8 SEClight
E9
5 Indoor blower fan failure Flash 6 time/8 SEClight
E5
6 Outdoor feedback failure Flash 7 time/8 SEClight
E7
7 Open door failurelight
Flash 3 time/8 SEC E0
8 Outdoor coil pipe TEMP. sensor failurelight
Flash 4 time/8 SEC E1
9 (EEPROM) communicate failurelight
Flash 6 time/8 SEC E6
Outdoor unit
1 Outdoor TEMP. sensor failurelight
Flash 1 time/8 SEC E2
2 Outdoor coil pipe TEMP. sensor failurelight
Flash 2 time/8 SEC E3
3 Over current protect of compressorlight
Flash 3 time/8 SEC E7
4 TEMP. sensor of exhaust failurelight
Flash 4 time/8 SEC E1
5 Communicate failurelight
Flash 6 time/8 SEC E6
6 Module protectionlight
Flash 7 time/8 SEC E5
7/22/2019 20115272209
40/45
11 . TROUBLE SHOOTING
Is CN (Tr sensor connector)
connected properly?
Is Tr sensor resistance value
(5KO at 25? ) normal?
Indoor P. C. board is defective. Replace P. C. board.
Connect CN properly.
Replace TA sensor.
Is CN (TP1 sensor connector)
connected properly?
Is TP1 sensor resistance value
(5KO at 25? ) normal?
Indoor P. C. board is defective. Replace P. C. board.
Connect CN properly.
Replace TC sensor.
YES
YES
YES
YES
NO
NO
NO
NO
Indoor Tr sensor
error
Indoor TP1 sensor
error
7/22/2019 20115272209
41/45
Turn off power
supply once, andturn it on again.
Does
compressor
continue to
operate?
Start to operate indoor
unit in cooling
operation at airflow
level LOW,wait
three minutes..
Does indoor
fan operate?
Fan motor
operatesnormally.
Is it possible to detect AC
220V between
pin(high/middle/low) andpin(common) of motor
connector .
Replace indoor
fan motor.
Replace main
P.C. board.
Replace
bearing.
YES
YES
YES
NO
NO
NO
Turn off indoor unit and rotate
cross-flow fan by hand when the
unit is on standby.Is it possible to
rotate cross-flow fan by hand
properly?
Only indoor fan motor does not operate.
Is capacitor of indoor fan ok?
YES
NO
YES
Replace
capacitor
NO
(1) Is it possible to detect the power supply voltage (200-240V) between L and N on the terminal
block?
(2) Does the indoor fan motor operate in cooling operation?
7/22/2019 20115272209
42/45
Compressor does not operate.
Turn on power supply.
Does compressor delay
three minutes by
temperature changes or
others?
Does OPERATION
indication indicate?
Is it possible to detect AC
220-240V on terminal
block or contactor of
compressor?
Are all of compressor
cords normal?
Is compressor motor
winding normal?(Check
winding resistor.)
Is capacitor for
compressor normal?
Is overload relay normal?
Does compressor start?
Does compressor stop
after a while?
Is gas quantity normal?
(Check gas pressure.)
Microcontroller is defective or
miniature relay is defective..
Is resistance value of room
sensor (Tr) and heat exchanger
sensor (TP1) normal?
Room sensor or heat
exchanger sensor is
defective.
Replace room sensor
or heat exchanger
sensor.
Compressor is defective.
Capacitor is defective.
Overload relay is defective.
Compressor is defective.
Gas shortage (Gas leak)
Compressor is defective.
Replace P.C. board.
Rewire or replace
defective cords.
Replace compressor.
Replace capacitor.
Replace overload
relay.
Supply gas.
Replace compressor.
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO NO
NO
NO
NO
NO
NO
NO
NO
Check power supply.
Replace compressor.
Wait three minutes
(1) Is the room temperature higher than the preset temperature in cooling operation?
(2) Is the crossover cable connected properly?
7/22/2019 20115272209
43/45
Replace
P.C. board.
Is receiver on
indoor unit exposed
to direct sunlight?
Batteries are
exhausted.
Press START/STOP
button.
Is there any thyristor
fluorescent light
nearby?
Does indoor unit
operate when
moving remote
control near receiver
or indoor unit?
P.C. board isdefective.
Is transmission
mark indicated?
Press RST button
on remote control
with tip of pencil.
Press START/STOP
button.
Does radio sound is
affected by remote
control when a
signal is transmitted
at distance of 5 cm
from radio?
Does indoor unit
start to operate by
automatic restart
function?
Is transmission
mark indicated?
Does indoor unit
beep and operate?
Remote control is
defective.
Keep indoor unit
away from
thyristor
fluorescent light.
Avoid direct
sunlight.
Replace
batteries.
Normal
operation
Replace remote
control.
The unit does not beep at all.
OPERATION indication on
indoor unit is not indicated.
NONO
NONO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
7/22/2019 20115272209
44/45
Trouble
Is the power
applied to the unit?
Check power supply mains or
interconnection wires
Is the power normal? check
the voltage between L&N of
terminal block
Check the wiring of indoor and
outdoor
Press the power ON/OFF button
of wire control or remote control
YES
YES
NO
NO
Does the beeperbeep?
Is the display all
off?
Check the connector on display
PCB connected to control PCB
Check the display PCB itself
Is the unit display
normal?
Does outdoor unit run?
Does the
compressor run
normally?
Check the failure code
according to the failure
table
Normal
Check the
compressor ,wires
and its
capacitor.
YES
YES
YES
YES
YES
YES
NO
NO
NO
Does the control
ok?
Does the control
PCB ok?
Control failure
Control PCB failure
NO
NO
YES
NO
Trouble shooting
NO
Does the indoorunit run?
7/22/2019 20115272209
45/45
Indoor unit and outdoor unit dont operate
Indoor and outdoor unit
dont operate
Press emergency key, does
the air conditionerrunning?
Replace fuse of
indoor PCB.
YES
YES
YES
NO
NO
NO
NO
Make the power
supply ok.
Replace remote
control.
YES
NO
Replace remote
receiver or displaypanel.
NO
YES
YES
Replace transformer.Does the transformer has
output?
Does the fuse of indoor
PCB burn out?
Change a good remote,
does the air conditioner
running?
Is the power supply no
problem?
Does the 12V and 5V of
indoor PCB have?Replace PCB.
normal
Does the electric switch
cut off?
Does the electric switch
cut off after a few
nimutes?
Is the wires of indoor
unit and outdoor unit no
problem?
YES
Reconnect the wires.NO
Is the insulationof
indoor unit and outdoorunit no problem?
YES
Find the reason and
replace the failurecomponet.
NO
Is the resistanceof each
main component no
problem?
Rreplace the failure
componet.
NO
YES
YES
YES