Upload
electrific
View
217
Download
0
Embed Size (px)
Citation preview
8/6/2019 ad29167j
http://slidepdf.com/reader/full/ad29167j 1/4
Application Da
29-16
Pag
Time/Current Characteristi c Curves forWestinghouse Series C ® J-FrameCircuit Breakers
December 1998Mail ed to : E/29-100A Westinghouse
AB DE-ION ®
Circuit Breakers
Breaker Descript ion Curve No. Page
Series C Types JDB, JD, HJD Equipped W ith Type JTTherm al-Magneti c Trip Uni t ............................................................. SC-4247-87C 2
Series C Types JDC Equipped W ith Type JTTherm al-Magneti c Trip Uni t ............................................................. SC-4248-87B 3
Individual ov ersize copies of curves listed above pr inted on onion-skin paper are availabin limited quantity from:
Cutler-Hammer
Westinghouse &Cutler-Hammer ProductsFive Parkway CenterPitt sburgh , PA 15220
When ordering on ion-skin curves, use numb er at bottom of page wh ere curve appears,i.e., SC-4547-87B. Requests for full sets of curves will not be honored.
Cutler-Hammer
Westinghouse &Cutler-Hammer ProductsFive Parkway CenterPittsburgh, Pennsylvania, U.S.A. 15220
8/6/2019 ad29167j
http://slidepdf.com/reader/full/ad29167j 2/4
Application Data
29-167J
Page 2
AB DE-ION Circuit Breakers
December 1998
Series C Types JDB, JD, HJD Equipped Wit h Type JT Thermal-Magnetic Trip Unit
Curve No. SC-4247-87C
Maximum
(125-225A)
Adjustable Magnetic Trip
5 X±20% ±10%
1 0 X
(250A)
(70-100A)
Interrupting RatingDetermines Endof Curve
TypicalTrip UnitNameplate
Individual PoleAdjustments
Maximum Single PoleTrip Times at 25°C�
ThermalMagneticTripUnit
C PushtoTrip
MagneticMultiplesOf In
10
7.5
10 5
7.5
10 5
Amps(In)
Cat.No.40°C
7.5
5
Minimum
Circuit Breaker Time/Current Curves
Series C ® J-Frame Circuit BreakersEquipped with Type JT Thermal-Magnetic Trip Unit
Catalog Types JDB, JD, HJD Circuit Breakers, 2, 3 and 4 Poles
For application and coordination purposes only. Thermal calibrationbased on 40°C ambient, cold start. Connected with four (4) feet ofrated wire (60°C up to 125 amps, 75˚C above 125 amps) per terminal.Tested in open air with current in all poles. Instantaneous calibrationbased on single-pole tests.
Maximum Voltage600 V., Ac (50/60 Hz.)250 V., Dc
Breaker RatingRated Amperes (In)
Single pole test data at 25°C based on NEMA Procedures(AB 4-1991) for verify ing performance of molded case circuitbreakers.
Note: For additional information on the trip uni t, see IL 29C600.
Interrupting Rating
�
Instantaneous Trip Amperes(See Figure Below)
70, 90, 100,125, 150, 175,200, 225, 250
500 to 1000% of trip unit rating. (Dc valuesare approximately 40% higher)
UL/CSA
RMS Sym. kA, 50/60 Hz.240 V.
BreakerType
JDBJDHJD
480 V. 600 V. 250 V.
101022
IEC 157-1 (P1)
RMS Sym. kA, 50/60 Hz.
240 V., (Ue) 380 V., (Ue) 415 V., (Ue) 250 V., (Ue)
kA, Dc
kA, Dc
6565
100
353565
181825
101022
6565
100
353565
353565
JDBJDHJD
100
50
30
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
T I M E I N S E C O N D S
1,000
500
300
200
5,000
3,000
2,000
1 H O U R
1 M
I N U T E
2 H O U R S
T I M E I N S
E C O N D S
10,000
100
50
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
1,000
500
300
200
5,000
3,000
2,000
1 H O U R
1 M
I N U T E
2 H O U R S
1 0 0
8 0
6 0
9 0
7 0
5 0
1 0 0 0
8 0 0
6 0 0
9 0 0
7 0 0
5 0 0
4 0 0
3 0 0
2 0 0
1 0 ,
0 0 0
8 0 0 0
6 0 0 0
9 0 0 0
7 0 0 0
5 0 0 0
4 0 0 0
3 0 0 0
2 0 0 0
1 0 0 ,
0 0 0
8 0 ,
0 0 0
6 0 ,
0 0 0
9 0 ,
0 0 0
7 0 ,
0 0 0
5 0 ,
0 0 0
4 0 ,
0 0 0
3 0 ,
0 0 0
2 0 ,
0 0 0
1 0 , 0
0 0
8 0 0 0
6 0 0 0
9 0 0 0
7 0 0 0
5 0 0 0
4 0 0 0
3 0 0 0
2 0 0 0
1 0 0 0
8 0 0
6 0 0
9 0 0
7 0 0
5 0 0
4 0 0
3 0 0
2 0 0
1 0 0
8 0
6 0
9 0
7 0
5 0
1 0 0 , 0
0 0
8 0 , 0
0 0
6 0 , 0
0 0
9 0 , 0
0 0
7 0 , 0
0 0
5 0 , 0
0 0
4 0 , 0
0 0
3 0 , 0
0 0
2 0 , 0
0 0
Maximum Interrupting Time
CURRENT IN PERCENT OFBREAKER TRIP UNIT RATING (In)
CURRENT IN PERCENT OFBREAKER TRIP UNIT RATING (In)
10,000
30
8/6/2019 ad29167j
http://slidepdf.com/reader/full/ad29167j 3/4
8/6/2019 ad29167j
http://slidepdf.com/reader/full/ad29167j 4/4
Application Data
29-167J
Page 4
AB DE-ION Circuit Breakers
December 1998
Printed in U.S.A.
Cutler-Hammer