Upload
vuongnhi
View
256
Download
0
Embed Size (px)
Citation preview
21MF2-S/U/RU , 21PF2-S/U/RU
7 – 1
CHAPTER 7. CHASSIS LAYOUT
[1] CHASSIS LAYOUT
33
3
(QKITPD746WJN3 )
3
QP
WB
FD
74
7W
JN3
21MF2-S / U / RU21PF2-S / U / RU
A
C
B
D
E
F
G
H
2 1098765431
21MF2-S/U/RU , 21PF2-S/U/RU
CHAPTER 8. BLOCK DIAGRAM
[1] BLOCK DIAGRAM: MAIN UNIT
21MF2-S / U / RU21PF2-S / U /RU
A
C
B
D
E
F
G
H
2 1098765431
8 – 1
21MF2-S/U/RU , 21PF2-S/U/RU
19181716151413121110
8 – 2
21MF2-S/U/RU , 21PF2-S/U/RU
[2] BLOCK DIAGRAM: CRT UNIT21MF2-S / U /RU21PF2-S /U / RU
A
C
B
D
E
F
G
H
2 1098765431
8 – 3
21MF2-S/U/RU , 21PF2-S/U/RU
9 – 1
TV21MF2-S/U/RU , 21PF2-S/U/RUService Manual21MF2-S/U/RU , 21PF2-S/U/RUMarketE CHAPTER 9. DESCRIPTION ON SCHEMATIC DIAGRAM
[1] DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTES:
DISCONNECT THE AC PLUG FROM THE AC OUT-
LET BEFORE REPLACING PARTS.
SEMICONDUCTOR HEAT SINKS SHOULD BE RE-
GARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
1.
2.
NOTES:
The unit of resistance "ohm" is omitted.(K = 1000 ohms, M = Mega ohm).
1.
All resistors are 1/16 watt, unless otherwise noted.2.
All capacitors are µF, unless otherwise noted.(P = µµF).
3.
VOLTAGE MEASUREMENT CONDITIONS:
Voltages in parenthesis measured with no signal.1.
Voltages without parenthesis measured with 3mV B & Wor Colour signal.
2.
All the voltages in each point are measured with VTVM.3.
WAVEFORM MEASUREMENT CONDITIONS:
The colour bar generator signal of 1.0V peak applied atpin (41) of IC801.
1.
Approximately 4V AGC bias.2.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE ( - ) IS DI-
RECTLY CONNECTED WITH AC MAINS VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN ISOLAT-
ING TRANSFORMER BETWEEN TV RECEIVER AND
AC LINE TO ELIMINATE HAZARD OF ELECTRIC
SHOCK.
CAUTION:
This circuit diagram is a standard one, prited circuits may
be subject to change for product improvement without pri-
or notice.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " " ( ) ARE IMPO-
TANT FOR MAINTAINING THE SAFETY OF THE SET.
BE SURE TO REPLACE THESE PARTS WITH SPECI-
FIED ONES FOR MAINTAINING THE SAFETY AND
PERFORMANCE OF THE SET.
32
21MF2-S/U/RU , 21PF2-S/U/RU
10 – 1
CHAPTER 10. WAVEFORM
[1] WAVEFORMS
129.16 Vp-p (H) 114.16 Vp-p (H) 140.83 Vp-p (H)
500 Vp-p1.02 KVp-p (H) 52.08 Vp-p (V) 4.08 Vp-p (V) 130 Vp-p (H)
59.16 Vp-p (H)4.58 Vp-p (H)4.83 Vp-p (V) 1.45 Vp-p (V)5.83 Vp-p (H)
0.96 Vp-p (H) 4.75 Vp-p (H) 4.37 Vp-p (H) 5.16 Vp-p (H) 5.29 Vp-p (H)
21MF2-S/U/RU , 21PF2-S/U/RU
TV21MF2-S/U/RU , 21PF2-S/U/RUService Manual21MF2-S/U/RU , 21PF2-S/U/RUMarketE CHAPTER 11. SCHEMATIC DIAGRAM[1] SCHEMATIC DIAGRAM: CRT UNIT ( 21MF2-S / U , 21PF2-S / U )
[2] SCHEMATIC DIAGRAM: CRT UNIT ( 21MF2-RU , 21PF2-RU )
21MF2-S/U21PF2-S/U
A
C
B
D
1 2 3 4 5 6 7 8 9 10
A
C
B
D
1 2 3 4 5 6 7 8 9 10
11 – 1
21MF2-S/U/RU , 21PF2-S/U/RU
[3] SCHEMATIC DIAGRAM: MAIN UNIT21MF2-S/U21PF2-S/U
A
C
B
D
E
F
G
H
2 1098765431
11 – 2
21MF2-S/U/RU , 21PF2-S/U/RU
19181716151413121110
11 – 3
21MF2-S/U/RU , 21PF2-S/U/RU
A
C
B
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
11 – 4
21MF2-S/U/RU , 21PF2-S/U/RU
10 11 12 13 14 15 16 17 18 19
11 – 5