8/9/2019 GMS44PX6S
1/5
Page - 1 - of 5
NO: DT1215012- 02
Super Quiet, Superior Life!
Wide ly app l i ed in Te lecom, Ren ta l , Ou tdoor Pr o ec ts Min in e t c .
RP Series
GMS44PX6/S Generator Set Specification
8/9/2019 GMS44PX6S
2/5
GMS44PX6/S
Page - 2 - of 5
3-Phase, 60Hz@1800RPM kVA 55
Standby PowerkW 44
kVA 50Prime Power
kW 40
Voltage V 480/277
480V 60.1Ampere (A)208V 138.8
8 hours (Standard) 102Fuel TankCapability (L) 24 hours (Optional) 308
Open Type 91.9Noise Level at 7meters (dBA) Silent Type 66.9
Notes 1) Ambient reference conditions: 1,000 mbar, 27 , 30% relative humidity;2) Also available in the following voltages: 440/254V-416/240V-220/127V-208-120V 3) ESP (Standby Power): the maximum power available under varying loads. Only for standby and emergency use. No overload is permissible.
PRP (Prime Power): the maximum power available under varying loads for continuous operation. A 10% overload is permissible for 1 hour every 12 hours.
Features BenefitsTightly structure, excellent design and craft
High durability at maximum performance
Excellent cooling system, reliable operation under
harshest conditions
Designed with safety in mind
Earth leakage protection
Quick fix electrical power connections
Function stability credibility, service convenience
Low operating cost results in optimal economy
Gets the job done wherever you are
Maximum economy through minimum downtime
Operation, and maintenance
Performance Specification and Craftwork Performance Specification Telephone Interference, ElectromagnetismEfficiency of Rated Power 96.3% TIF 50
Time needed from start-up to full load(inductive) 125 seconds
THF 2%
Time needed from start-up to 50% load(inductive) allowed
8 seconds Radio interference in compliance with BS800 and VEDLEVELS G and N.
1.1 times overload operation time (hour) 1
2.0 time overload operation time (minute) 1
Voltage Regulation, steady s tate 1%
Voltage Regulation, transient state 20%-15%Voltage Settle Time 5 seconds
Voltage Fluctuation Ratio 0.5%
Frequency Regulation, steady state0.5%adjustable
Frequency Regulation, transient state 5%
Frequency Settle Time 5 seconds
Frequency Fluctuation Ratio 0.5%
Recovery Time 0.5 seconds
Craftwork Steel base frame with AV mounting standard 8h fuel tank with flexible rubber fuel tube, fuellevel indicator and drainage
Overall sprayed powder coating Whole set documents, including Installation Manual,Operation Manual, Spare Parts Catalog, Circuit Diagram
Criterion ISO3046, ISO8528, BS4999, BS5514, BS5000PT99 AS1359, IEC34 UTE5100, VDE0530 ISO9001:2000
8/9/2019 GMS44PX6S
3/5
GMS44PX6/S
Page - 3 - of 5
Engine Specification Alternator SpecificationBrand Powerlink Brand Stamford Leroy Somer
Model PX4108G Model BCI184J LSA43.2S15No. of Cylinders and Cycle 4L, 4 Stroke Rated Output (kVA) 55
480V 60.1Induction System NA Rated current (A)
208V 138.8
Governing 5% Exciter BrushlessDisplacement (L) 5 THF BS EN60034- 1
8/9/2019 GMS44PX6S
4/5
GMS44PX6/S
Page - 4 - of 5
Control SystemPLC-702HCPLC-702HC key manual start module is a manual engine control moduledesigned to control the engine via a key switch and push buttons on the frontpanel. The module is used to start and stop the engine and indicate faultconditions, automatically shutting down the engine and giving a true first upfault condition of an engine failure.Standard Control Function Manual Engine Control Module Low Oil Pressure High Engine Temperature Auxiliary Shutdown
PLC-5220Microprocessor control, with high stability and credibilityMains supply and generator operation monitoringIndicating operation status and fault conditionsMultiple protections; multiple parameters display, like pressure, temp.Manual and automatic work mode selectableReal time clock for time and date display, overall runtime display, 99log entriesOverall power output displayIntegral speed/frequency detecting, telling status of start, ratedoperation, over speedCommunication with PC via RS485 OR RS232 interface, usingMODBUS protocol.
PLC-1FGenerator Protection(ANSI) Over-/under voltage Over-/under frequency Over current Reverse power voltage unbalance phase sequence error
Engine Control Start preparation (preheating or prelubrication) Start/stop sequences with selectablenumber of start attempts Fuel solenoid selection (coil type) Idle speed control Local of remote start/stop Stop sequence with cooling down Running speed detection selectable
O Generator Hz/VO Charger alternator input (W
terminal)O Binary input (D+)O Oil pressure
Clear Text Display 128 x 64 pixel backlight STN Graphic symbol messaging Clear text alarm messages Clear text diagnostics for bothhardwired inputs and CANbusmessages (J1939) Log book holding 150 log entries Real time clock for time and date
Generator Monitoring 3-phase or single phase generator monitoring
O Voltage /current /frequency /power /reactive power
Dimension and Weight
Over speed Protection Protection hold-off timer Charge Failure warning
GMS44PX6S (Silent Type)Length Width Height, mm Weight (kg):
2400 1155 1625 950
GMS44PX (Open Type)Length Width Height, mm Weight (kg)
1750 890 1380 900
8/9/2019 GMS44PX6S
5/5
GMS44PX6/S
Page - 5 - of 5
Optional
Engine Alternator Generator Set Fuel System Canopy
Coolantheater
Space heater AVR PMG with regulator Anti-damp and anti-corrosion
treatment Anti-condensation heater
Tools with themachine
Low fuel level alarm Automatic fuel feedingsystem
24 hours fuel tank
Canopy Trailer Container
LubricatingSystem Exhaust System Cooling System Control Panel Voltages
Oil with themachine
Protection board from hotness Low frequency silencer
Front heat protection 50 radiator Coolant (-30 OC)
Remote control panel Automatic parallelingcontrol panel Automatic Transfer Switch (ATS)
440/254V 416/240V 220/127V 208-120V
Specification may change without prior notice.For more info., please contact your local distributors .
Local Distributor
BGC Paralleling ControlSystem
ATS Mobile Trailer Air Switch