    Wide ly app l i ed in Te lecom, Ren ta l , Ou tdoor Pr o ec ts Min in e t c .

    RP Series

    GMS44PX6/S Generator Set Specification

  • 8/9/2019 GMS44PX6S

    2/5

    GMS44PX6/S

    Page - 2 - of 5

    3-Phase, 60Hz@1800RPM kVA 55

    Standby PowerkW 44

    kVA 50Prime Power

    kW 40

    Voltage V 480/277

    480V 60.1Ampere (A)208V 138.8

    8 hours (Standard) 102Fuel TankCapability (L) 24 hours (Optional) 308

    Open Type 91.9Noise Level at 7meters (dBA) Silent Type 66.9

    Notes 1) Ambient reference conditions: 1,000 mbar, 27 , 30% relative humidity;2) Also available in the following voltages: 440/254V-416/240V-220/127V-208-120V 3) ESP (Standby Power): the maximum power available under varying loads. Only for standby and emergency use. No overload is permissible.

    PRP (Prime Power): the maximum power available under varying loads for continuous operation. A 10% overload is permissible for 1 hour every 12 hours.

    Features BenefitsTightly structure, excellent design and craft

    High durability at maximum performance

    Excellent cooling system, reliable operation under

    harshest conditions

    Designed with safety in mind

    Earth leakage protection

    Quick fix electrical power connections

    Function stability credibility, service convenience

    Low operating cost results in optimal economy

    Gets the job done wherever you are

    Maximum economy through minimum downtime

    Operation, and maintenance

    Performance Specification and Craftwork Performance Specification Telephone Interference, ElectromagnetismEfficiency of Rated Power 96.3% TIF 50

    Time needed from start-up to full load(inductive) 125 seconds

    THF 2%

    Time needed from start-up to 50% load(inductive) allowed

    8 seconds Radio interference in compliance with BS800 and VEDLEVELS G and N.

    1.1 times overload operation time (hour) 1

    2.0 time overload operation time (minute) 1

    Voltage Regulation, steady s tate 1%

    Voltage Regulation, transient state 20%-15%Voltage Settle Time 5 seconds

    Voltage Fluctuation Ratio 0.5%

    Frequency Regulation, steady state0.5%adjustable

    Frequency Regulation, transient state 5%

    Frequency Settle Time 5 seconds

    Frequency Fluctuation Ratio 0.5%

    Recovery Time 0.5 seconds

    Craftwork Steel base frame with AV mounting standard 8h fuel tank with flexible rubber fuel tube, fuellevel indicator and drainage

    Overall sprayed powder coating Whole set documents, including Installation Manual,Operation Manual, Spare Parts Catalog, Circuit Diagram

    Criterion ISO3046, ISO8528, BS4999, BS5514, BS5000PT99 AS1359, IEC34 UTE5100, VDE0530 ISO9001:2000

  • 8/9/2019 GMS44PX6S

    3/5

    GMS44PX6/S

    Page - 3 - of 5

    Engine Specification Alternator SpecificationBrand Powerlink Brand Stamford Leroy Somer

    Model PX4108G Model BCI184J LSA43.2S15No. of Cylinders and Cycle 4L, 4 Stroke Rated Output (kVA) 55

    480V 60.1Induction System NA Rated current (A)

    208V 138.8

    Governing 5% Exciter BrushlessDisplacement (L) 5 THF BS EN60034- 1

  • 8/9/2019 GMS44PX6S

    4/5

    GMS44PX6/S

    Page - 4 - of 5

    Control SystemPLC-702HCPLC-702HC key manual start module is a manual engine control moduledesigned to control the engine via a key switch and push buttons on the frontpanel. The module is used to start and stop the engine and indicate faultconditions, automatically shutting down the engine and giving a true first upfault condition of an engine failure.Standard Control Function Manual Engine Control Module Low Oil Pressure High Engine Temperature Auxiliary Shutdown

    PLC-5220Microprocessor control, with high stability and credibilityMains supply and generator operation monitoringIndicating operation status and fault conditionsMultiple protections; multiple parameters display, like pressure, temp.Manual and automatic work mode selectableReal time clock for time and date display, overall runtime display, 99log entriesOverall power output displayIntegral speed/frequency detecting, telling status of start, ratedoperation, over speedCommunication with PC via RS485 OR RS232 interface, usingMODBUS protocol.

    PLC-1FGenerator Protection(ANSI) Over-/under voltage Over-/under frequency Over current Reverse power voltage unbalance phase sequence error

    Engine Control Start preparation (preheating or prelubrication) Start/stop sequences with selectablenumber of start attempts Fuel solenoid selection (coil type) Idle speed control Local of remote start/stop Stop sequence with cooling down Running speed detection selectable

    O Generator Hz/VO Charger alternator input (W

    terminal)O Binary input (D+)O Oil pressure

    Clear Text Display 128 x 64 pixel backlight STN Graphic symbol messaging Clear text alarm messages Clear text diagnostics for bothhardwired inputs and CANbusmessages (J1939) Log book holding 150 log entries Real time clock for time and date

    Generator Monitoring 3-phase or single phase generator monitoring

    O Voltage /current /frequency /power /reactive power

    Dimension and Weight

    Over speed Protection Protection hold-off timer Charge Failure warning

    GMS44PX6S (Silent Type)Length Width Height, mm Weight (kg):

    2400 1155 1625 950

    GMS44PX (Open Type)Length Width Height, mm Weight (kg)

    1750 890 1380 900

  • 8/9/2019 GMS44PX6S

    5/5

    GMS44PX6/S

    Page - 5 - of 5

    Optional

    Engine Alternator Generator Set Fuel System Canopy

    Coolantheater

    Space heater AVR PMG with regulator Anti-damp and anti-corrosion

    treatment Anti-condensation heater

    Tools with themachine

    Low fuel level alarm Automatic fuel feedingsystem

    24 hours fuel tank

    Canopy Trailer Container

    LubricatingSystem Exhaust System Cooling System Control Panel Voltages

    Oil with themachine

    Protection board from hotness Low frequency silencer

    Front heat protection 50 radiator Coolant (-30 OC)