Length, ft? = 7,282 0 214
Weight, ppf? = 5.95 0 22
Tensile Rating, lbs? = 178,000
Tensile Safety Factor, (0 - 1.0)? = 0.80 Density, ppg 8.5
Weight of the Entire String Above Weakest Pipe, lbs? = 167,200 Buoyancy Factor 0.870
Tensile Rating of the Weakest Pipe in String, lbs? = 178,000 MOP, lbs 100,000
Tensile Safety Factor for Weakest Pipe, (0.1 to 1.0)? = 0.80 Max Pull, lbs 364,901
Weight of the Entire String Below Weakest Pipe, lbs? = 4,699
Weight of Traveling Block, lbs? = 60,000
Drilling ApplicationMOP or MAX PULLMicrosoft Excel 97
See Pipe Tables @ cell I5 for tubular data... Review the User Notes starting @ cell
If the Max Pull Calculation exceeds 80% of the Tensile Rating for the pipe that extends to the surface, then and only then will 80% ofthis pipe's Tensile Rating plus the weight of the Traveling Equipment be considered the MAX PULL FOR THIS STRING. If the pipein use is classified as 'Used API Premium Class', a Tensile Safety Factor of 1.0 is acceptable. Those cells with a red triangle in theupper right hand corner contain a user comment, move the cursor to the cell for viewing.
THE END