MaxPullOnDrillString.xls

Embed Size (px)

Citation preview

  • 7/28/2019 MaxPullOnDrillString.xls

    1/1

    Name of Company:

    Well Name & Number:

    Date:

    Length, ft? = 7,282 0 214

    Weight, ppf? = 5.95 0 22

    Tensile Rating, lbs? = 178,000

    Tensile Safety Factor, (0 - 1.0)? = 0.80 Density, ppg 8.5

    Weight of the Entire String Above Weakest Pipe, lbs? = 167,200 Buoyancy Factor 0.870

    Tensile Rating of the Weakest Pipe in String, lbs? = 178,000 MOP, lbs 100,000

    Tensile Safety Factor for Weakest Pipe, (0.1 to 1.0)? = 0.80 Max Pull, lbs 364,901

    Weight of the Entire String Below Weakest Pipe, lbs? = 4,699

    Weight of Traveling Block, lbs? = 60,000

    Drilling ApplicationMOP or MAX PULLMicrosoft Excel 97

    See Pipe Tables @ cell I5 for tubular data... Review the User Notes starting @ cell

    If the Max Pull Calculation exceeds 80% of the Tensile Rating for the pipe that extends to the surface, then and only then will 80% ofthis pipe's Tensile Rating plus the weight of the Traveling Equipment be considered the MAX PULL FOR THIS STRING. If the pipein use is classified as 'Used API Premium Class', a Tensile Safety Factor of 1.0 is acceptable. Those cells with a red triangle in theupper right hand corner contain a user comment, move the cursor to the cell for viewing.

    THE END

    INFORMATION FOR MOP CALCULATION

    INFORMATION FOR MAX PULL CALCULATION

    MUD / FLUID INFORMATION

    RESULTS

    HWDP DRILL COLLARSWEAKEST DP