Upload
majid-mohammadian
View
220
Download
0
Embed Size (px)
Citation preview
7/29/2019 nw10s10a0603b_netre
1/2
NIVOFLOATF L O A T L E V E L S W I T C H E S
O U R P R O F E S S I O N I S Y O U R L E V E L
F o r s e w a g e
LE
VEL
SW
ITC
H
ES
7/29/2019 nw10s10a0603b_netre
2/2
The NIVOFLOAT NW-100 type tilting float level switch is suitable for level
switching of various liquids, especially sewage in shafts, tanks, basins or
cisterns. The double-chambered float is made of injection moulded toughpolypropylene that ensures good water-proof protection.
The contacting microswitch is incorporated in the float.
The cable of the NIVOFLOAT NW-100 level switch is fed through the water-proof passage and the monolithic structure of the injection moulded plastic housing.
The cable of the level switch is a flexible insulated copper cable with 3x1 mm 2 cross-section and PVC or Neopren outer insulation. Different control tasks such as
liquid level monitoring and pump control can be realized successfully with NIVOFLOAT.
APPLICAT IONS
GENERAL DESCRIPTION
TECHNICAL DATA
OPERATION
ORDER CODES
For industrial and communal sewageSuitable also for drinking waterSpecial float shapeDouble-chambered floatTank filling / emptying controlMedium temperature max. +50CProcess pressure max. 2 barIP68 protection
Type NWo-1-oo-1
Switching differential ~ 400 mm (constant)
Medium temperature 0C +50C
Medium pressure 0.2 MPa (2 bar)
Material of the float Polypropylene
Float volume 920 cm3
Rating of the microswitch 10 A, 250 V AC, AC1
Electrical life-span 107 switches
Mechanical protection IP 68
Cable 9 mm, 3x1 mm2
Cable length 5 m, 10 m, 20 m
Mass 1.01 kg, without cable
NIVOFLOAT NW -1- -1
Cable length Code
5 m 05
10 m 10
20 m 20
Cablematerial
Code
PVC P
Neopren N
The NIVOFLOAT tilting level switch featuring mercury free contact is suitable for level switching of sewage, polluted
liquids or drinking water. The double-chambered float and the sealing of the cable outlet provide hermetic sealing and
water-proof operation. The float should be immersed to the required level and fix if it is needed. At the given level,the float will switching by tilting. The special shape of the float ensures proper tilting without using a counterweight.
Filling control
APPLICAT ION EXAMPLES
Emptyingcontrol
nw10s10a0603b
Nive
lcoreservestherig
httochangetechnica
ldatawithoutnotice!
N I V EL C O P R O C E S S C O N TR O L C O .
H - 1 0 4 3 B U D A P E S T , D U G O N I C S U . 1 1.
TEL . : (36-1 ) 889-0100 u FAX : (36-1 ) 889-0200
E-mai l : [email protected] http://www.nivelco.com
DIMENSIONS
WIRING
Multi-levelswitching
filling
emptying
fixation