of 119 /119
SENSORS AND TRANSDUCERS SENSORS AND TRANSDUCERS Accelerometers Accelerometers Pressure sensors Pressure sensors Differential pressure Differential pressure switches switches Sound pressure sensors Sound pressure sensors Rotation sensors Rotation sensors Rotation velocity sensors Rotation velocity sensors Displacement sensors Displacement sensors Temperature sensors Temperature sensors Heat flow sensors Heat flow sensors LLC “SENSOR ENTERPRISE “ZAVOD RAPID” Chernigov, Ukraine

SENSORS AND TRANSDUCERS Accelerometers Pressure sensors Differential pressure switches Sound pressure sensors Rotation sensors Rotation velocity

Embed Size (px)

Text of SENSORS AND TRANSDUCERS Accelerometers Pressure sensors Differential pressure switches Sound...

  • LLC SENSOR ENTERPRISE ZAVOD RAPIDChernigov, Ukraine

  • Temperature measuring sensorsSENSORS AND TRANSDUCERS 006It is assigned for measuring of temperature of a flat surfaceCopper resistance thermometer with cable-end splitting in a plastic caseCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -196 till +200VALUECharacteristic accuracy 0,5Service life at the temperature range from 196 till +10033 000 hoursStorage warranty period20 yearsThermal inertia indexless than 0,01 secThermometer resistance at 017, 23, 30, 53, 60, 100 OhmsMassless than 8 gSpace industry

  • 006Calibrating characteristics in the working temperature rangeSPECIFICATIONfrom -196 till +200VALUECharacteristic accuracy 0,5Service life at the temperature range from 196 till +10033 000 hoursStorage warranty period15 yearsThermal inertia indexless than 0,01 sThermometer resistance at 017, 23, 30, 53, 60, 100 OhmsMassless than 2,5 gSENSORS AND TRANSDUCERSCopper resistance thermometer in a plastic caseIt is assigned for measuring of temperature of a flat surfaceTemperature measuring sensorsSpace industry

  • 104It is assigned for measuring of temperature of surfaces with curvature radius 7..100 mmCopper resistance thermometer with cable-end splitting in a plastic caseCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -196 till +200VALUECharacteristic accuracy 0,5Service life at the temperature range from 196 till +10033 000 hoursStorage warranty period20 yearsThermal inertia indexless than 0,01 sThermometer resistance at 017, 23, 30, 53, 60, 100 OhmsMassnot more than 8 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 104Copper resistance thermometer in a plastic casefrom -196 till +200VALUE 0,533 000 hours15 yearsless than 0,01 s17, 23, 30, 53, 60, 100 Ohmsnot more than 4,5 gIt is assigned for measuring of temperature of surfaces with the curvature radius 7..100 mmSENSORS AND TRANSDUCERSTemperature measuring sensorsCalibrating characteristics in the working temperature rangeSPECIFICATIONCharacteristic accuracyService life at the temperature range from 196 till +100Storage warranty periodThermal inertia indexThermometer resistance at 0MassSpace industry

  • 000Sensing element

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -196 till +200VALUECharacteristic accuracy 0,5Service life at the temperature range : from -196 till +100 from -10 till +10033 000 hours20 yearsThermal inertia indexless than 0,01 s17, 23, 30, 53, 60, 100 Ohms0,5 g55 000 hoursSENSORS AND TRANSDUCERSTemperature measuring sensorsStorage warranty periodThermometer resistance at 0MassSpace industry

  • 006Sensing element

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -196 till +200VALUECharacteristic accuracy 0,5Service life at the temperature range: from -196 till +100

    from -10 till +10033 000 hoursStorage warranty period20 yearsThermal inertia indexless than 0,01 sThermometer resistance at 017, 23, 30, 53, 60, 100 OhmsMass0,5 g55 000 hoursSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 012Platinum resistance thermometer without current terminal splitting (sensing element).

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -260 till +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 015,25,34,46,60,100 OhmsMassnor more than 0,5 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 018Platinum resistance thermometer without current terminal splitting (sensing element).

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -260 till +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 015,25,34,46,60,100,500 OhmsMassnot more than 0,5 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 018Platinum resistance thermometer without current terminal splitting (sensing element).

    It is assigned for measuring of temperature of surfaces with the curvature radius 7100 mmCalibrating characteristics in the working temperature rangeSPECIFICATIONfrom -260 till +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 15,25,34,46,60,100,500 OhmsMassnot more than 0,5 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 018Platinum resistance thermometer

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATION -260 +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 15,25,34,46,60,100,500 OhmsMassnot more than 8 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 018Platinum resistance thermometer

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATION -260 +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 15,25,34,46,60,100,500 OhmsMassnot more than 8 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 110Platinum resistance thermometer

    It is assigned for measuring of temperature of surfaces with the curvature radius 7100 mmCalibrating characteristics in the working temperature rangeSPECIFICATION -260 +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 15,25,34,46,60,100 OhmsMassnot more than 8 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 110Platinum resistance thermometer

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATION -260 +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 15,25,34,46,60,100 OhmsMassnot more than 8 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 025Platinum resistance thermometer

    It is assigned for measuring of temperature of surfacesCalibrating characteristics in the working temperature rangeSPECIFICATION -260 +300VALUECharacteristic accuracy 0,5

    Guarantied lifetime during warranty period, when it operates within temperature range from -260 till +100 33 000 hoursStorage warranty period20 yearsThermometer resistance at 0 34 OhmsMassnot more than 0,5 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 166It is assigned for measuring of temperature of the undisturbed non-aggressive nonconductive liquids and gasesTemperature measuring range, at pressure value 200 kg/m2SPECIFICATIONfrom 77,15 till 473,15 VALUEThermal inertia index at the air velocity value 5 0,5 / not more than 51 sStorage warranty period15 yearsThermometer resistance at 0 23, 30, 53, 60, 100 Ohms Massnot more than 0,08 kgSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 168It is assigned for measuring of temperature of the undisturbed non-aggressive nonconductive liquids and gases

    It is non-hermeticTemperature measuring rangeSPECIFICATION 77,15 473,15 VALUEThermal inertia index at the air velocity value 5 0,5 m/s not more than 51 sStorage warranty period20 yearsThermometer resistance at 0 23, 30, 53, 60, 100 OhmsMassnot more than 0,02 kgTotal operating time, when it operates within temperature range from 123,15 till 373,15 . 13 000 hours SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 168It is assigned for measuring of temperature of non-aggressive gases within compartment volumes.

    The sensor is non-hermetic

    The sensors end connection is 2 144 12 (male)Temperature measuring rangeSPECIFICATIONfrom 77,15 till 473,15 VALUEThermal inertia index at the air rate 5 0,5 / not more than 51 sStorage warranty period15 yearsThermometer resistance at 0 273,15 Ohms; 92 Ohms Massnot more than 0,06 kgTotal operating time, when it operates within temperature range from 123,15 till 373,15 120 000 hours SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 119It is assigned for measuring of temperature of aggressive liquids and gases.

    There are 14 modifications of the thermometer, differing by the lengths of its submersible part - from 30 mm till 56 mm, and electrical resistance value from 23 till 100 Ohms Temperature measuring range, at maximal pressure 600 kg/sm2 SPECIFICATION -196 +200 VALUEThermal inertia index in the boiling water not more than 4 sStorage warranty period20 yearsThermometer resistance at 0 from 23 till 100 OhmsMassnot more than 0,06 kgSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 221Copper resistance thermometer

    It is assigned for measuring of temperature of surfaces (including the surfaces that undergo the direct sun radiation)Temperature measuring rangeSPECIFICATION -50 +200 VALUECalibration characteristic accuracy 0,5 Storage warranty period12 yearsThermometer resistance at 0 50, 100, 200 OhmsMassnot more than 1 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 222

    It is assigned for measuring of temperature of a neutral gaseous mixturesTemperature measuring rangeSPECIFICATION 0 +50 VALUECalibration characteristic accuracy 0,5 Storage warranty period12 yearsThermometer resistance at 0 100, 200 OhmsMassnot more than 1,5 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 232Resistance thermometer with cable-end splitting in a plastic case

    It is assigned for measuring of temperature of: flat surfaces; pipeline surfaces, diameter 14 mm and more; spherical surfaces, diameter 20 mm and more Temperature measuring rangeSPECIFICATION -130 +200 VALUECalibration characteristic accuracynot more than 1,5 Storage warranty period15 yearsThermometer resistance at 0 53,00,3 and 1000,9 OhmsMassnot more than 1,5 g -130 +170 33 000 hoursSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 033The thermometer is assigned for measuring of temperature of a flat surfacesTemperature measuring rangeSPECIFICATIONfrom -50 till +1000 VALUEStorage warranty period15 yearsThermometer resistance at 0 12, 15, 25, 34 Ohms SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 041The thermometer is assigned for measuring of temperature of surfaces with curvature radius 7..100 mmTemperature measuring rangeSPECIFICATIONfrom -50 till +1000 VALUEThermal inertia indexless than 0,01 s Storage warranty period15 yearsThermometer resistance at 0 12,15,25,34 Ohms Massnot more than 10 gSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 251The thermometer is assigned for measuring of temperature of surfacesTemperature measuring rangeSPECIFICATIONfrom -260 till +300 VALUETotal calibration characteristic accuracy 0,5 Thermometer resistance at 0 46, 100, 500 Ohms First cycle durationnot less than 15 min.Assigned resource: within temperature range from -130 till +160

    within temperature range from -260 till +300 100 cycles15 cyclesSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 198The thermometer is assigned for measuring of temperature of cryogenic liquidsTemperature measuring rangeSPECIFICATIONfrom 13 till 473 VALUEThermal inertia indexnot more than 3 sStorage warranty period20 yearsThermometer resistance at 0 100, 500 Ohms Massnot more than 74 gTotal calibration characteristic accuracy: - within temperature range from 13 till 273 - within temperature range from 273 till 473

    0,1 0,5 SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 227The thermometer is assigned for measuring of temperature of cryogenic liquidsTemperature measuring rangeSPECIFICATION 13 473 VALUEThermal inertia indexnot more than 3 sStorage warranty period20 yearsThermometer resistance at 025,46,100, and 500 OhmsMassnot more than 12 gTotal calibration characteristic accuracy: - within temperature range from 13 till 273 - within temperature range from 273 till 473

    0,1 0,5 SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 203The thermometer is assigned for measuring of temperature of cryogenic liquids

    It has ten modificationsTemperature measuring rangeSPECIFICATIONfrom 13 till 473 VALUEThermal inertia indexnot more than 2 sStorage warranty period15 yearsThermometer resistance at 0100 and 500 OhmsMassnot more than 74 gTotal calibration characteristic accuracy: - within temperature range from 13 till 273 - within temperature range from 273 till 473

    0,1 0,5 SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 165It is assigned for measuring of temperature of a non-aggressive smooth nonconductive gases and liquids.It has five modifications, differing by electrical resistance value at 0 . It is hermetical up to pressure value of 200 kgf/sm2Temperature measuring rangeSPECIFICATIONfrom -260 till +300 VALUEThermal inertia index at air velocity value 50,5 m/sless than 3 sStorage warranty period10 yearsThermometer resistance at 0 from 25 till 100 OhmsMassnot more than 0,08 kgSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 175Temperature measuring rangeSPECIFICATIONVALUEnot more than 3 sStorage warranty period20 yearsThermometer resistance at 0 from 25 till 100 Ohms Massnot more than 0,02 kgThermal inertia index at air velocity value 50,5 m/sfrom -260 till +300 It is assigned for measuring of temperature of a non-aggressive smooth nonconductive gases and liquids.It has five modifications, differing by electrical resistance value at 0 . It is no hermeticalSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 073It is assigned for measuring of temperature of a non-aggressive and neutral gases and liquids.It has 15 modifications, differing by electrical resistance value at 0 and the length of submersible part - from 30 to 56 mm. It is hermetical up to pressure value of 300 kgf/sm2Temperature measuring rangeSPECIFICATIONVALUEThermal inertia index in boiling waternot more than 0,3 sStorage warranty period15 yearsThermometer resistance at 0 from 25 till100 OhmsMassnot more than 0,06 kgfrom -260 till +250 SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 085Temperature measuring rangeSPECIFICATIONVALUEThermal inertia index in boiling waternot more than 4 sStorage warranty period20 yearsThermometer resistance at 0 from 25 till 100 OhmsMassnot more than 0,06 kgfrom -260 till +300 It is assigned for measuring of temperature of an aggressive gases and liquids under the maximal pressure 600 kgf/cm2.It has 15 modifications, differing by electrical resistance value at 0 and the length of submersible part - from 30 till 56 mm. SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 062Temperature measuring rangeSPECIFICATIONVALUEThermal inertia index in boiling waternot more than 4 sStorage warranty period20 yearsThermometer resistance at 0from 25 till100 OhmsMassnot more than 0,06 kgfrom -260 till +300 It is assigned for measuring of temperature of both aggressive and non-aggressive gases and liquids under the maximal pressure 300 kgf/cm2.It has 15 modifications, differing by electrical resistance value at 0 and the length of submersible part - from 30 to 56 mmSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 007Setting point temperaturesSPECIFICATIONVALUECalibration from the setting point within the range 10 Storage warranty period6 yearsMassnot more than 0,09 kgTemperature measuring sensors14 and 20 It is assigned for measuring of temperature of non-aggressive liquidsSENSORS AND TRANSDUCERSSpace industry

  • 470Temperature measuring rangeSPECIFICATIONVALUENominal static characteristic of the sensor meets GOST 3044Warranty period (after putting into operation)12 yearsMassnot more than 0,32 kgfrom 0 till +2500 Thermal inertia indexnot more than 0,25 sIt is assigned for one-time measuring of the non-aggressive gaseous medium temperatureMaximal working pressure40 MPaSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 135Temperature measuring rangeSPECIFICATIONVALUERated static characteristicMeets GOST3044Storage warranty period (after putting into operation)15 yearsMassnot more than 0,3 kgfrom -50 till +1200 Thermal inertia indexnot more than 0,2 sIt as assigned for measuring of temperature of non-aggressive liquids and gasesMaximal working pressure60 MPa SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 142Temperature measuring rangeSPECIFICATIONVALUERated static characteristic of the sensor meets GOST 3044Storage warranty period (after putting into operation)15 yearsMassnot more than 0,3 kgfrom -50 till +1200 Thermal inertia indexnot more than 0,8 sIt as assigned for measuring of temperature of aggressive and oxidizing liquids and gasesMaximal working pressure 60 MPa SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 243Temperature measuring rangeSPECIFICATIONVALUENominal static characteristic of the sensor meets GOST 3044Warranty period (after putting into operation)15 yearsMassnot more than 55 gfrom -200 till +1000 Measuring accuracynot more than 1%It is designed for measuring of temperature of the flat surfaces and of surfaces with the curvature radius from 5 mm and more of constructive elements, that are made of various steel and aluminum alloys, titanium and non-metalsElectrical resistance of the thermometers circuitfrom 14,5 Ohms till 65 OhmsSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 257Temperature measuring rangeSPECIFICATIONVALUERated static characteristic of the sensorMeets GOST 3044Storage warranty period (after putting into operation)15 yearsMassnot more than 55 gfrom -200 till +1100 Measuring accuracynot more than 1%Thermometer is as assigned for measuring of temperature of gases

    It has two sensing elementsElectrical resistance of the thermometers circuitfrom 14,5 till 65 Ohms SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 249Temperature measuring rangeSPECIFICATIONVALUERated static characteristic of the sensor meetsGOST 3044Storage warranty period12 yearsMassnot more than 0,2 kgfrom -50 till +1000 Thermal inertia indexnot more than 0,4 sIt is assigned for measuring of temperature of gaseous medium.

    Measuring temperature range is 200850Maximal working pressure 80 MPa 253It is assigned for measuring of temperature of gaseous flows.SENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 2000Temperature measuring rangeSPECIFICATIONVALUEWorking pressure 10 Pa Storage warranty period12 yearsMass: - 2000 - 2000-01 - 2000-02not more than 0,09 not more than 0,11 not more than 0,13 from -215 till +50 Individual transformation function of each 2000 is DC voltage drop dependent on temperature under working current 100 microamperes, it corresponds to individual transformation function of the thermo-diode sensing device -100 which is part of the sensor.This function is represented both as table and as specific polynomial at the passport of each sensor.Sensor accuracy: - in the range from minus 215 till minus 175 - in the range from minus 175 till minus 30 - in the range from minus 30 till +30 - in the range from +30 till +50 less than 0,05 less than 0,5 less than 0,05 less than 0,5 It is assigned for measuring of temperature of liquid supercooled oxygen in the filling-drainnig lines, non-aggressive and aggressive liquids, as well as product Vinil at various tanks and lines of carrier rocets.Thermal inertia indexnot more than 4 sSENSORS AND TRANSDUCERSTemperature measuring sensorsSpace industry

  • 125SENSORS AND TRANSDUCERSTemperature measuring sensorsTemperature sensor -125 is assigned for measuring of temperature of aviation fuel, oil, and air-oil emulsion.Sensor produces electric signals, that are proportional to the measured temperature of aviation fuel, oil, and air-oil emulsion, for control-and-monitoring system of an aviation engine.Sensor contains two sensing elements (two channels) with the nominal resistances of 50 Ohms at 0C.Effective measured temperature range 60 +300 CRated static characteristic of the sensor is Pt 50 (GOST 6651, IEC 751)Measurement accuracy of the sensor in all operating conditions is less than = (0,3 + 5 10-3 | t| ), where is sensor accuracy, in , t is measured temperature, in .Index of thermal inertia (time constant) 2.5 sOutput connectorplug 30-10/14-1Weight 50 g.Warranty storage periodtwo yearsWarranty operation life13 years after putting into operationAircraft industry

  • 1251SENSORS AND TRANSDUCERSTemperature measuring sensorsTemperature sensor -1251 is assigned for measuring of temperature of aviation fuel, oil, and air-oil emulsion.Sensor produces electric signals, that are proportional to the measured temperature of aviation fuel, oil, and air-oil emulsion, for control-and-monitoring system of an aviation engine.Sensor contains two sensing elements (two channels) with the nominal resistances of 50 Ohms at 0C.Effective measured temperature range 60 +300 CRated static characteristic of the sensor is Pt 50 (GOST 6651, IEC 751)Measurement accuracy of the sensor in all operating conditions is less than = (0,3 + 5 10-3 | t| ), where is sensor accuracy, in , t is measured temperature, in .Index of thermal inertia (time constant) 2.5 sOutput connectorplug 8533-1Y 12-12PNWeight 50 gWarranty storage periodtwo yearsWarranty operation life13 years after putting into operationAircraft industry

  • SENSORS AND TRANSDUCERSTemperature measuring sensors application,Aircraft IndustryAircraft industry

    Sensor Is used in the engines-125

    -1251-450, -450-2,-222-25, -500,3-117-1, series 1

    -450, -450-2, -136-2, -18 series 3,

  • 4000.03.0820 It is assigned for measuring of outflowing gas jets in the process of benchmark trials of engines

    Features:Operability under impact of destabilizing factors- high reliability-it not requires additional maintenance during operationTemperature measuring rangeSPECIFICATIONVALUEMeasuring accuracy within the range from +100 till +900 8,6 Electrical resistance under normal conditions81 OhmsMassnot more than 0,03 kgfrom 0 till +900 Rated static characteristic of the sensormeets the calibration chart Lof GOST 3044 The sensor consists of a thermocouple of type of (L) which is mounted in the case and connected to cable ends. The working hot junction is placed in the case tip, and cable outlets are free ends.The operating principle of the sensor is based on a thermal e. m. f. generation due to temperature difference between the working hot junction and free ends.SENSORS AND TRANSDUCERSTemperature measuring sensors

  • --400It is assigned for transformation of the temperature of outgoing gases into thermal e.m.f., which is returned to the measuring and regulating unit as a DC voltage, that is proportional to mean temperature of gases from engine.Temperature measuring rangeSPECIFICATIONVALUEMeasuring accuracy within the range from +100 till +900 8,6 Electrical resistance under normal conditions100,2 Ohms Massnot more than 0,25 kgfrom 0 till +900 Rated static characteristic of the sensormeets the calibration chart of GOST 3044 Time constant at the gas flow velocity more than 100 m/s2 sFeatures:Operability under impact of destabilizing factors- high reliability-it not requires additional maintenance during operationThe sensor contains of thermal outlets of the thermocouple cable of type of . These outlets are connected to the cable ends. Thermal outlets form a hot junction, and cable ands form a free ends.Thermal outlets meet 92-4313 SENSORS AND TRANSDUCERSTemperature measuring sensors

  • 120--400 It is assigned for measuring of temperature of deceleration of air flow. The sensor generate a signal to a regulator.Temperature measuring rangeSPECIFICATIONVALUESensor static accuracy: - in the range from +30 till +110 - in the range from +110 till +170 2 3 Electrical resistance at 00460,25 Ohms Massnot more than 0,12 kgfrom -60 till +200 Rated static characteristicmeets the calibration chart of GOST 3044 Time constant at the gas flow velocity more than 45 m/s6 sThe sensor contains of a sensing element (of two independent resistors) mounted within the case.Calibration method according to the category II of 92-0694. The sensor generates two independent signals. Calibration table as the sensor resistance dependence of temperature at points -100, -50, 0, 20, 50, 100, 150, 200 is supplied to the passport.The sensor operating principle is based on a property of platinum wire to change its resistance with the temperature change.SENSORS AND TRANSDUCERSTemperature measuring sensors

  • 005Heat flow sensorsRadiant heat flux density measuring rangeSPECIFICATIONVALUERated static characteristicmeets GOST 3044-94Storage warranty period12 yearsMassnot more than 0,4 kgfrom 0 till 630 kW/m2 Sensitivity: - 005 - 005-01 - 005-0254-89 V m2/kW28-49 V m2/kW13-36 V m2/kWIt is assigned for one-time measuring of a radiant heat flux densitySENSORS AND TRANSDUCERSSpace industry

  • 013Radiant heat flux density measuring rangeSPECIFICATIONVALUEStorage warranty period12 yearsMassnot more than 0,35 kgfrom 0 till 2500 kW/m2 It is assigned for one-time measuring of a total heat flux densitySENSORS AND TRANSDUCERSHeat flow sensorsSpace industry

  • () 4270-7382-0 Measuring temperature rangeSPECIFICATIONVALUEMassnot more than 1 kgfrom -189 till -181 The sensor is assigned for measuring of the mean temperature of an oxide within a pipeline.

    The sensor is a part of a pipeline with the resistance thermometer , that is built in it. The sensing elements of the sensor receive the liquid temperature and change their resistances in a way, that stated in GOST 6651-84.Rated temperature-187Working liquid density at the rated temperature1,155 kg/liter Thermal inertia indexnot more than 1,5 sInternal pressurenot more than 14,2 MPaThe sensor contains three independent sensing elements; the resistance value of each sensing element is 200 Ohms at 0. Storage warranty period10 yearsSENSORS AND TRANSDUCERSHeat flow sensorsSpace industry

  • Thermocouple collector -4(-1)SENSORS AND TRANSDUCERSThermocouple collectorsThermocouple collector BT-4(-1) is designed for transformation of the aircraft engine outgoing gas temperature into the thermal electromotive force and producing two autonomous DC voltages, that are proportional to the averaged gas temperature, and sending them to automatic control system.

    The collector consists of four inseparable doubled thermocouples that form two independent measuring circuits which are ended in a mutual carrier socket.

    SPECIFICATION VALUE

    Averaged measured temperature range 60 +1150COperating measured temperature range+200 +800 CNominal static characteristicChromel-alumel XA(K) (GOST 3044, IEC)Allowable variation of thermocouple materialclass 2 (GOST 3044)Index of thermal inertia (time constant) 2.5 s(gas flow velocity 215 m/s, static pressure 10.68104 Pa)Quantity of independent electric signals2in every thermocouple

    Aircraft industry

  • SENSORS AND TRANSDUCERSThermocouple collector application,Aircraft IndustryThermocouple collector -4(-1)Aircraft industry

    Sensor Is used in the engines-4(-1)-450, -4501,-450, -450-2

  • SENSORS AND TRANSDUCERSThermocouple -36ThermocouplesAircraft industryIt is assigned for measuring of gas temperature at turbine of air gas-turbine engines Number or output signalstwoTemperature calibration typeXAWorking mediumGTE combustion materialsEffective measuring rangefrom 450 till 1000 CMaximal working temperature1110 C (up to 5% of service life)Rated static characteristicXA(K) GOST 3044Maximum permission errorclass 2 (GOST 3044)Mass 0.14 kgInsulation resistance:Normal conditionsnot less than 0.5 MOhms700 C at working endnot less than 0.05 MohmsInsulating strength350 V (under normal conditions)

  • SENSORS AND TRANSDUCERSThermocouple -36ThermocouplesBT-36 outline drawingThermocouple BT-36 applicationAircraft industry

    Sensor is used in the engines-36-2500 (series 1),3-117-1,3-117-1 (series 1),3-117-1 (series 2),3-117-1 4/4E

  • Aircraft industryTwo-channel breaking temperature sensor is designed to produce electric signals, that are proportional to the measured air temperature, and sending them to digital and analogous automatic control systems.Effective measured temperature range60 +300 CNominal static characteristic of the sensor is Pt 50 (GOST 6651, IEC 751)Measurement accuracy of the sensor in the temperature range 60 +25 C = (0.35 + 5 10-3 | t| ), where is sensor accuracy, in , t is measured temperature, in .

    Measurement accuracy of the sensor in the temperature range +25 +300 C = (0.5 + 5 10-3 | t| ), Index of thermal inertia (time constant) 1.4 s(air flow velocity 150 m/s and static pressure up to 98 kPa) Weight 0.15 kgQuantity of independent electrical signals 2Operating life13 years

  • Aircraft industryBT-98 outline drawingBT-98 view

  • Aircraft industryBreaking temperature sensor BT-98 application

    Sensor Is used in the engines-98-4501, -4502,-450, -450-2,-450, -4502,-450, -500, -14, -336 (in -2,5),3-117--1, series 1,-500, -450

  • 306Pressure sensors and differential pressure switchesMeasuring range SPECIFICATIONVALUEWorking temperature range from +60 till -196 Storage warranty period15 yearsMassnot more than 0,18 kgfrom 0,1 till 5,0 kgf/cm2 It is assigned for transformation of fast-varying pressure of liquid and gaseous media to electric signalWorking frequency rangefrom 11,2 Hz till 11 000 Hz Switch sensitivity Not less than 50 mV/kgf cm2 Slowly varying pressure range from 0,5 till 5,6 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 308Pressure sensorsMeasuring range SPECIFICATIONVALUEWorking temperature range from +80 till -196 Storage warranty period15 yearsMassnot more than 0,18 kgfrom 1,2 till 56 kgf/cm2 It is assigned for transformation of fast-varying pressure of liquid and gaseous media to electric signalWorking frequency range from 11 Hz till 10 000 Hz Transducer sensitivitynot less than 4 mV/kgf cm2 Slowly varying pressure range from 110 till 1250 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 309Pressure sensorsMeasuring range SPECIFICATIONVALUEWorking temperature range from 77 till 473 Storage warranty period15 yearsMassnot more than 0,15 kgfrom 2,5 till 50 kgf/2 It is assigned for transformation of fast-varying pressure of liquid and gaseous media to electric signalWorking frequency range from 20 Hz till 10 000 HzTransducer sensitivityNot less than 10 mV/kgf cm2 Slowly varying pressure range from 110 till 900 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 612Pressure sensorsMeasuring range SPECIFICATIONVALUEWorking temperature range from 293 till 2273 Storage warranty period8 yearsMassnot more than 0,12 kgfrom 0,45 till 56 kgf/cm2 It is assigned for transformation of fast-varying pressure of liquid or gaseous non-aggressive media to electric signalWorking frequency range from 20 Hz till 10 000 HzTransducer sensitivitynot less than 16 mV/kgf cm2 Slowly varying pressure range from 28 till 630 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 611Pressure sensorsMeasuring range SPECIFICATIONVALUEWorking temperature range from 77 till 473 Storage warranty period15 yearsMassnot more than 0,15 kgfrom 0,45 till 56 kgf/cm2 It is assigned for transformation of fast-varying pressure of liquid and gaseous media to electric signalWorking frequency range from 31,5 Hz till 5 000 HzTransducer sensitivity not less than 20 mV/kgf cm2 Slowly varying pressure range from 28 till 630 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 611Pressure sensorsMeasuring range SPECIFICATIONVALUEWorking temperature range from 77 till 473 Storage warranty period8 yearsMassnot more than 0,1 kgfrom 0,45 till 56 kgf/cm2 It is assigned for transformation of fast-varying pressure of liquid or gaseous non-aggressive media to electric signalWorking frequency range from 31,5 Hz till 5 000 Hz Transducer sensitivity not less than 20 mV/kgf cm2 Slowly varying pressure range 40 630 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 222Pressure sensorsUpper limit of the absolute pressure effective range, for various versions:SPECIFICATIONVALUEBasic error, from the upper limit of effective rangenot more than 2,5 % Massnot more than 0,65 kg0 - 1500 mm Hg It is assigned for measuring of static and slowly varying pressure of gaseous media and of vapor phase.

    Supply voltage is 27 VDC.

    The sensor preserves its performance capability under the temperature of environment up to +50SENSORS AND TRANSDUCERSSpace industry

  • 219Pressure sensorsAbsolute pressure effective range, for various versions:SPECIFICATIONVALUEWorking temperature range from -500 till +500 Massnot more than 250 g(0-0,16;0-0,30; 0-0,60) 105 PaIt is assigned for measuring of absolute pressure of working media: gaseous or vapor phase.

    Supply voltage is 6 VDC.Initial output signal, equivalent to unit supply voltage at the receiving chamber pressure of 13,3 Pa (0,1 mm Hg) in the range 0,15 mV/VOverall dimensions 87 60 mm SENSORS AND TRANSDUCERSSpace industry

  • 220Pressure sensorsAbsolute pressure effective range, for various versions:SPECIFICATIONVALUEMassnot more than 160 g(0-1,25;0-2,5; 0-5) 105 Pa It is assigned for measuring of absolute pressure of working media: gaseous or vapor phase.

    Supply voltage is 6 VDC.Initial output signal, equivalent to unit supply voltage at the receiving chamber pressure of 13,3 Pa (0,1 mm Hg) in the range 0,15 mV/VOverall dimensions 87 30 mm SENSORS AND TRANSDUCERSSpace industry

  • 68Pressure sensorsAbsolute pressure effective range, for various versions:SPECIFICATIONVALUEWorking temperature range from -600 till +2500 Massnot more than 200 g(0-0,3;0-0,6;0-1,25;0-2,5;0-5,0;0-10;0-16) 105 PaIt is assigned for measuring of absolute pressure in liquid and gaseous media

    Supply voltage is 6 VDC.Initial output signal, equivalent to unit supply voltage at the receiving chamber pressure of 13,3 Pa (0,1 mm Hg) in the range 0,15 mV/VOverall dimensions 87 30 mm SENSORS AND TRANSDUCERSSpace industry

  • 206Pressure sensorsMeasuring pressure rangeSPECIFICATIONVALUEMeasurement accuracynot more than 0,8% Massnot more than 150 gfrom 0 till 60 MPa,12 ranges (0-1,0; 1,4; 2,0 ;2.8; 4,0; 5,6; 8,0; 11,0; 16,0; 22,0; 30,0; 45,0; 60,0) MPaIt is assigned for measuring of statico-dinamic pressure.

    The sensor is of tensoresistive membrane type. The sensing element is thin-film bridge circuit.The sensor is used with the secondary data-processing equipmentSupply voltage is 6 VDCOutput signal+9 mVOverall dimensions 22 90 mm Working frequency range from 0 till 200 Hz Working temperature range from -1960 till +500 SENSORS AND TRANSDUCERSSpace industry

  • 212Pressure sensorsMeasuring pressure rangeSPECIFICATIONVALUEMeasurement accuracynot more than 0,6% Massnot more than 120 gfrom 0 till 125,0 MPa,(0-1,0;1,4;2,0;2.8;4,0;5,6;8,0;11,0;16,0;22,0;30,0;45,0;60,0;90,0;125,0) MPaIt is assigned for measuring of statico-dinamic pressure.

    There are two version, with heat exchange bushing and without it; and 13 ranges of the rated pressure.Supply voltage is 6 VDC.Output signal+9 mVOverall dimensions 22 80 mmWorking frequency rangefrom 0 till 200 Hz Working temperature range from -300 till +500 The sensor is of tensoresistive membrane type. The sensing element is thin-film bridge circuit.The sensor is used with the secondary data-processing equipmentSENSORS AND TRANSDUCERSSpace industry

  • 1201Pressure sensorsMeasuring pressure rangeSPECIFICATIONVALUEMeasuring mean square deviation0,25% Massnot more than 300 gfrom 0,5 till 180,0 MPa,(0-1,0;1,4;2,0;2.8;4,0;5,6;8,0;11,0;16,0;22,0;30,0;45,0; 60,0;90,0;125,0;180,0) MPaIt is assigned for the measuring of excess pressure and pressure, that rising with gradient up to 1000 MPa/s. measured media: gases, vapor and liquids.

    Supply voltage is 27 VDC.Overall dimensions: - amplifier - transducer 25 76 mm30 76 mmWorking temperature range from -500 till +500 Output signal: amplitude 2,8..5 V, frequency 15..22 kHz.It has 27 versions in dependence of material (flexible tube of and rigid tube of 121810) and length of a jumper and the value of a measured pressure.SENSORS AND TRANSDUCERSSpace industry

  • 1202Pressure sensorsMeasuring pressure rangeSPECIFICATIONVALUEMeasuring mean square deviation0,15% Massnot more than 320 gfrom 0,5 till 60,0 MPa, (0-1,0;1,4;2,0;2.8; 4,0;5,6;8,0; 11,0;16,0;22,0;30,0;45,0;60) MPaIt is assigned for the measuring of excess static and slow varying pressure and pressure. Measured media: vapor and liquids.

    Supply voltage is 27 VDC.Overall dimensions: - amplifier - transducer25 76 mm30 76 mmWorking temperature range from -500 till +500 It has 27 versions in dependence of length of a jumper cable (0.5 m, 1 m, 1.5 m) and the value of a measured pressure.Output signal: amplitude 2,8..5 V, frequency 15..22 kHz.SENSORS AND TRANSDUCERSSpace industry

  • -122Pressure sensorsSENSORS AND TRANSDUCERSThe transducer is designed for remote measuring of absolute pressure of neutral liquids and gases, including:Fuels-1; -5; -1; -1; -1; -7; -8; -8, and other aviation fuels; Oils -50-4; -836/1; -8; air and other aviation oils. the transducer sends signals to the engine regulator or to control devices.

    Absolute pressure transducer

  • -0,4Maximal working pressureSPECIFICATIONVALUETriggering pressureCurrent across contacts0,30,45 MPaDifferential pressure switch

    The switch is designed for inspection of clogging of fuel, oil, and hydraulic filters and generating a signal to the warning lamp.

    Measured media: aviation fuel and oilDC voltage0,04 MPa Triggering accuracy0,01 MPa 27 V10% SENSORS AND TRANSDUCERSInspected medium temperature 60 +175 Mass 0.1 kgAircraft industryDifferential pressure switch

  • -1,0Maximal working pressureSPECIFICATIONVALUETriggering pressureCurrent across contacts0,3 A0,45 MPaDifferential pressure switch

    The switch is designed for inspection of clogging of fuel, oil, and hydraulic filters and generating a signal to the warning lamp.

    Measured media: aviation fuel and oilDC voltage0,10 MPa Triggering accuracy0,02 MPa 2710% Maximal pressure drop0,13 MPaInspected medium temperature -60 +175 0Massfrom -60 till +175 0not more than 0,1 kgSENSORS AND TRANSDUCERSAircraft industryDifferential pressure switch

  • -0,6Maximal working pressureSPECIFICATIONVALUETriggering pressureCurrent across contacts0,3 A0,45 MPaDifferential pressure switch

    The switch is designed for inspection of clogging of fuel, oil, and hydraulic filters and generating a signal to the warning lamp.

    Measured media: aviation fuel and oilDC voltage0,06 MPa Triggering accuracy 0,012 MPa 2710% Maximal pressure drop0,13 MPaInspected medium temperature -60 +175 0Massfrom -60 till +175 0not more than 0,1 kgSENSORS AND TRANSDUCERSAircraft industryDifferential pressure switch

  • SENSORS AND TRANSDUCERSDifferential pressure switch applicationDifferential pressure switchAircraft industry

    SwitchIs used in the engines-0,4; -0,6; -1,0-25, -27, -222-25,222-25, -222-25,3-117-1, -25,-450, -4501,-450, -450-2, -436-148, -436-1, -436-, -136-2, -36 (all series), -136 (all series),combustion-oil unit 317070500

  • SENSORS AND TRANSDUCERSSmall size pressure switch (- , -, -, -)The switch is designed for contact breaking (contact closure) of the electric circuit when the pressure of the working medium in the input unit of the switch reaches triggering (actuation) level.

    Product code without letter A (e.g. ) means the variant of switch with normally closed contacts (without pressure);Product code with letter A (e.g. -) means the variant of switch with normally open contacts (without pressure); Product code with letter C (e.g. -) means the switch with special connecting pipe;Product code with letter M (e.g. -) means the switch for higher temperature;Product code with letter C (e.g. -) means the switch with extended precision.Point of adjustment0.05; 0.12; 0.15; 0.16; 0.17; 0.25 MPaError of activation (for a point of adjustment):0.05 MPa 0.02 MPa0.12; 0.15; 0.16 MPa 0.03 MPa0.25 MPa0.045 MPa() 0.05 Mpa0,01 MPa() 0.17 MPa 0,015 MPaDirect current voltage27 V 10%Current across contact:with resistive load1.5 Awith inductive-resistive load0.5 A Measured medium temperature (for variants): (-) 60 +180 C (-) 60 +220 CWeight (for variants): (-) 0.18 kg (-) 0.22 kg

  • SENSORS AND TRANSDUCERSSmall size pressure switch (- , -, -, -)Image of (-, -, -, -) Outline drawing for (-, -, -, -) and their seats

  • SENSORS AND TRANSDUCERSSmall size pressure switch applicationAircraft industrySmall size pressure switch (- , -, -, -)

    SwitchIs used in the engines (- , -, -, -)-9, -9, -9, -9 (series 1), -25, -27, -222-25, -14, -500 (all modifications), 222-25, -222-25,3-117-1, -25,-450, -4501, -450, -450-2, -18 (all series),-436-148, -436-1, -436-, -27, -136-2, -36 (all series), -136 (all series), 3-117 (all modifications),--2,5, --6,3/, --8/

  • 516 The sensor is assigned for conversion of acoustic pressure of gaseous medium to electric signalSPECIFICATIONVALUEWorking frequency rangefrom 10 till 4000 Hz Massnot more than 0,16 kgEffective acoustic pressure measuring rangefrom 200 till 63240 PaStorage warranty period14 years Slowly varying pressure range from 0,5 till 16 kgf/cm2 Sensibility 600 350 mV/kgf cm SENSORS AND TRANSDUCERSSpace industry

  • 517 The sensor is assigned for conversion of acoustic pressure of gaseous medium to electric signalSPECIFICATIONVALUEWorking frequency rangefrom 3 till 4000 HzMassnot more than 0,13 kgEffective acoustic pressure measuring rangefrom 30 till 35480 PaStorage warranty period 10 years Slowly varying pressure range from 0,1 till 2 kgf/cm2 Sensibility 5000 3000 mV/kgf cm . Working temperature rangefrom 203 till 473 SENSORS AND TRANSDUCERSSpace industry

  • -144It is assigned for measuring of rotary speed of shafts within the range of 0 - 21000 1000 rpm; one closing or disjunction of the contacts takes place every 50 10 turns of the input shaftMeasuring number of turnsSPECIFICATIONVALUEElectric circuit resistance on the assumptions of open contactsnot less than 10 MOhms Mass65030 g0 - 21000 1000 rpmTransient resistance of closed contacts, at current of 300 A under normal conditionsnot more than 0,5 OhmsOverall dimensions 143 110 mm Working temperature range from -500 till +700 SENSORS AND TRANSDUCERSSpace industryRotation velocity sensors

  • -513It is assigned for measuring of rotary speed from 1000 till 40 000 rpmSENSORS AND TRANSDUCERSSpace industryRotation velocity sensors

  • 1850It is assigned for conversion of shaft rotary speed to pulse-repetition frequency of electric pulses. Monitored rotary speed range is more then 3000 rpm.

    SPECIFICATIONVALUEOutput signal amplitude (with non-magnetic screen of thickness not more than 1,7 mm)not less than 100 mV Massnot more than 85 gMonitored rotary speed rangemore than 3000 rpmOverall dimensions 9,8 500 49,2 mm SENSORS AND TRANSDUCERSSpace industryRotation velocity sensors

  • 1856It is assigned for conversion of shaft rotary speed to pulse-repetition frequency of electric pulses.

    The transducer is hermetic.

    SPECIFICATIONVALUEOutput signal amplitude (with non-magnetic screen of thickness not more than 1 mm)not less than 100 mV Massnot more than 140 gMonitored rotary speed rangemore than 3000 rpmEnvironment temperature 1000 SENSORS AND TRANSDUCERSSpace industryRotation velocity sensors

  • 018It is assigned for conversion of shaft rotary speed to pulse-repetition frequency of electric pulses. Monitored rotary speed range is more then 1000 rpm.SPECIFICATIONVALUEOutput signal amplitude (RH is not less than 10 kOhms andH is not more than 10000 pF)from 0,15 till 10 VMonitored rotary speed rangemore than 1000 rpmOverall dimensions 600 24,5 ; 1000 24,5 mm SENSORS AND TRANSDUCERSSpace industryRotation velocity sensors

  • -10Rotation velocity sensorsSENSORS AND TRANSDUCERSRotation velocity sensor -10 is designed for measuring of angular velocity of a rotor and sending of relevant signal, that is similar to sinusoidal one, to control system.The sensor operates with the inductor which is a cogwheel made from the steel 142- or 3022-; number of teeth is 61, module is 2.5, and tooth length is 16 mm. The working cogwheel may be used as inductor.The voltage amplitude of the sensor on the active load 2 kOhms:with the rotational velocity 1400 revolutions per minute and the radial gap between the end face of the sensor and the inductor 1.3 mm 0.2 V;with the rotational velocity 14200 revolutions per minute and the radial gap between the end face of the sensor and the inductor 0.7 mm 10.0 VResistance of the winding of the sensor at normal conditions27040 Ohms;Warranty storage period3 years Warranty operation life7 years after putting into operation subject to storage periodWarranty life1000 hours for the engine -36 and 8000 hours for other enginesOperating temperature60 +250 Vibration frequency10 4000 Hz (with overloading up to 100g)Weight 0.1 kgConnecting to the loadby soldering of two connecting wires (with cross-section 0.75 mm2) to the finger contacts of the sensorAircraft industry

  • SENSORS AND TRANSDUCERS-10Rotation velocity sensorsAircraft industryRotation velocity sensor application

    Sensor Is used in the engines-10-2506, 3-117-1, 3-117-1-4 (4),3-117 (all models)

  • SENSORS AND TRANSDUCERS-15Rotation velocity sensorsRotation velocity sensor -15 is designed for measuring of angular velocity of a rotor and sending of two relevant independent electric signals, that are similar to sinusoidal ones, to control system.The sensor operates with the inductor which is a cogwheel made from the steel 2013; number of teeth is 32, module is 5, and tooth thickness is 15 mm. The working cogwheel may be used as inductor.The voltage amplitude of the sensor on the active load 20.2 kOhms as in the following table:

    Aircraft industry

  • -15 ()Rotation velocity sensorsSENSORS AND TRANSDUCERSResistance of the winding of the sensor at normal conditions477 Ohms;Operation life30,000 hours in the course of 15 yearsOperating temperature60 +180 Vibration frequency5 2000 Hz (with overloading up to 30g)Weight 0.2 kgConnecting to the loadby connector 28-4/14-15-15Aircraft industry

  • SENSORS AND TRANSDUCERS-15 ()Rotation velocity sensorsAircraft industryRotation velocity sensor application

    Sensor Is used in the engines-15 ()9-3, -450, -4501,-4502, -450, -4502,3-117-1, -22225,-436, -436-,

  • SENSORS AND TRANSDUCERS-1004Rotation velocity sensorsRotation velocity sensor -1004 is designed for measuring of angular velocity of a rotor and sending of two relevant electric signals, that are similar to sinusoidal ones, to control system.The sensor operates with the inductor which is a cogwheel made from the steel 302-; number of teeth is 61, module is 2.5, and tooth length is 16 mm. The working cogwheel may be used as inductor.The voltage amplitude of the sensor on the active load 2 kOhms:with the rotational velocity 1400 6000 revolutions per minute and the radial gap between the end face of the sensor and the inductor 1.3 mm 0.4 V;with the rotational velocity 6000 - 14200 revolutions per minute and the radial gap between the end face of the sensor and the inductor 1.1 mm 16.0 VResistance of the windings of the sensor at normal conditions:coil 1365 Ohms;coil 29010 OhmsSubject to the cable (resistance is approx. 0.72 Ohms/m)coil 1416 Ohms;coil 29511 OhmsOperation life40,000 hours in the course of 40 yearsOperating temperature60 +350 Vibration frequency5 2000 Hz (with overloading up to 30g)Weight 0.2 kgConnecting to the loadby the 4-wire cable in non-magnetic braided shieldAircraft industry

  • SENSORS AND TRANSDUCERS-1004Rotation velocity sensorsAircraft industry

  • -718Linear displacement sensorsIt is assigned for measuring of linear displacements of a blocks of mechanical systems, and their conversion to electric signalSPECIFICATIONVALUEMassnot more than 0,3 kgMeasuring range0-16 mm, 0-22 mm, 0-30 mm, 0-45 mm, 0-60 mm, 0-90 mm, 0-125 mm, 0-180 mm, 0-250 mm,0-350 mm, 0-500 mm, 0-700 mm, 0-750 mm.Cable length51515 mm Transducer supply voltage61 VDCOverall dimensions 33,5 40 90 mm Basic errornot more than 2%SENSORS AND TRANSDUCERSSpace industry

  • -721 (VT-721)Linear displacement sensorsIt is assigned for conversion of linear displacements of parts of a product to electric signalSPECIFICATIONVALUEMassnot more than 0,9 kgMeasuring range0-0,5 m, 0-1,0 m, 0-1,4 m, 0-2,0 m, 0-4,0 m, 0-5,6 m, 0-8,0 m, 0-11 m, 0-16 mCable length50015 mm Transducer supply voltage61 VDCOverall dimensions 43,5 76 120 mmBasic error1%SENSORS AND TRANSDUCERSSpace industry

  • -714It is assigned for measuring of linear and angle (in two perpendicular planes) displacements of a blocks of mechanical systems, and their conversion to electric signalSPECIFICATIONVALUEMassnot more than 1 kgMeasuring range: - along paths - along angles0-16 m 700Cable length50015 mm Transducer supply voltage61 VDCOverall dimensions 56 120 133 mmBasic error: - along linear displacements - along angle displacementsnot more than 1%not more than 2%SENSORS AND TRANSDUCERSSpace industryLinear displacement sensors

  • -712It is assigned for measuring of angle (in one plane) displacements of a blocks of mechanical systems, and their conversion to electric signal

    SPECIFICATIONVALUEMassnot more than 0,2 kgCable length51515 mm Transducer supply voltage61 VDCOverall dimensions 53 56 mmBasic errornot more than 1%Measuring range (radians, degrees)0-1,12 (0-64), 0-1,60 (0-92), 0-2,20 (0-126), 0-3,20 (0-183), 0-4,40 (0-252), 0-6,00 (0-344), 0-9,00 (0-516), 0-12,00 (0-688)SENSORS AND TRANSDUCERSSpace industryLinear displacement sensors

  • -713It is assigned for measuring of linear displacements of blocks of a product and their conversion to electric signal

    The transducer is meant for joint operation with a recording device which has input resistance not less than 500 kOhmsSPECIFICATIONVALUEMassnot more than 0,18 kgTransducer supply voltagr60,2 VDCStatic error under operation conditionsnot more than 2%Measuring range 0-5,6 mm, 0-8 mm, 0-11 mm, 0-16 mm, 0-22 mm, 0-30 mm, 0-45 mm SENSORS AND TRANSDUCERSSpace industryLinear displacement sensors

  • 001Contactless displacement sensorIt is assigned for positional checking of movable operating elements of executive mechanisms of technological equipment.

    The sensor is meant for expose to oils of type -10. The distance between two adjacent one-type sensors is not less than their diameter, and between different-type sensors is not less than the bigger sensor diameter.Service life is 107 cyclesRunning hours 18000 hours. SENSORS AND TRANSDUCERSSpace industry

  • -51 (VT-51)AccelerometersIt is assigned for measuring of linear accelerationSPECIFICATIONVALUEMassnot more than 0,5 Supply voltage27 (+7;-4) Basic error 3%Measuring rangefrom 11m/s2 till 4 000 m/s2 frequency ranges (0-8, 0-16, 0-32, 0-64, 0-256) Hz. Output voltage06 SENSORS AND TRANSDUCERSSpace industry

  • 722 (SD722)It is assigned for measuring of pressure

    Operation threshold is 35 kgf/cm2SENSORS AND TRANSDUCERSSpace industrySpecial designation sensors

  • 716 (SID716)It is assigned for measuring of excess pressureOperation threshold is 0,8 0,1 kgf/cm2SENSORS AND TRANSDUCERSSpace industrySpecial designation sensors

  • 707 (DID707)It is assigned for measuring of excess pressureIn the range 0 160 kgf/cm2

    SENSORS AND TRANSDUCERSSpace industrySpecial designation sensors

  • 718 (DR718)Negative pressure sensorWorking range is 0 - 0,25 kgf/cm2 SENSORS AND TRANSDUCERSSpace industrySpecial designation sensors

  • (DRD)Special designation sensorsPressure difference sensorWorking ranges: 0,125+0,125; 06; 00,025; 00,15; 00,25 kgf/cm2 SENSORS AND TRANSDUCERSSpace industry

  • 5556SPECIFICATIONVALUEIrregularity of the frequency responsenot more than 2,2 kgNumber of the fixed measuring ranges5Working temperature range -50 +500Relative humidity at temperature 2510 C 98%Air pressure2 atm.Linearity of amplitude characteristic accuracy (from 6 )0,4%1,5%MassThe transducer is assigned for joint working with isometric sensors of type of , (bridge circuits with a branch resistance 70035 Ohms and starting unbalance of 60%. \It has dust-ignition-proof construction.

    It has four measuring channels which are identical and mutually independent.Supply voltage27 (+7;-4) VDCNumber of frequency ranges7: : 0-16, 0- 32, 0-64, 0-125, 0-250, 0-500 and 0-700 Hz SENSORS AND TRANSDUCERSTransducersSpace industry

  • 5611 (VT5611)The transducer 5611 is assigned for measuring of rotary speedsSENSORS AND TRANSDUCERSTransducersSpace industry

  • TransducersSENSORS AND TRANSDUCERS 5611 (VT5611)The transducer 5611 is assigned for measuring of rotary speeds, it operates jointly with an inductive sensors which have the output voltage from 0,06 V till 10 V (-513, 018 et al.).

    The transducer is resistant to vibrations, strokes, linear accelerations, acoustic noise. It has the checking circuit for sensor transducer input circuit monitoring.

    Measuring range25 10 000 HzOutput signal0 60.2 VAccuracynot more than 1.6%Supply voltage28 (+6, -4) VDCCurrent consumptionnot more than 0.22 AOperating temperature rangefrom 50 till +50 CNumber of channels2Service life200 hoursCable length:sensor transducerup to 40 mtransducer recorderup to 70 mOverall dimensions5513073 mmMass1,35 kg

  • (URAN)The transducer is assigned for measuring of liquid medium level .It operates jointly with ultrasonic level sensors.

    Output information is represented as binary parallel code which has two service bits and 12 informational bits, of TTL levels

    SENSORS AND TRANSDUCERSTransducersSpace industryLevel of liquid measuring range 702000 mm (it depends by the sensor))Supply voltage 27(+7, -4) VDC Consumption current not more than 0.3 AWorking temperature range from -50 till +50 CService life 2000 hoursOverall dimensions 13112280 mmMass not more than 1,5 kg

  • (PRINT)The transducer is assigned for conversion of signals from thermometers (both resistance and thermoelectric ones) into input analog and digit signals for control systemsSENSORS AND TRANSDUCERSTransducersSpace industry

  • -01 (PRINT-01)The transducer is assigned for conversion of signals from thermometers (both resistance and thermoelectric ones) into input analog and digit signals for control systemsSENSORS AND TRANSDUCERSTransducersSpace industry

  • TransducersSENSORS AND TRANSDUCERS-01 (PRINT-01)

    Main technical dataParametersTolerance, %, not more thanDigit output for thermoresistanes0,15Digit output for thermocouples0,45Analog output for thermoresistanes0,25Analog output for thermocouples0,45Supply voltage, V27Output signal Analog output, V0 .. 6,2Digit output12 position codeSwitching regimesAutonomous and synchronous Measuring scales7 resistive and one voltageOperating temperature range, C50 .. +50Current consumption, mA, no more than70Number of switched channels32Warranty resource, hours2000Weight, kg1,1

  • (PSTD)Transducer is designed for voltage supplying of pressure sensors (of type of VT 206, VT 212 et al) and for conversion of their signals into input signals for control systemsSPECIFICATIONVALUEBasic errornot more than 5%Measuring range of R/R(2,8; 5,6; 16)10-3 Sensor supply voltage6 VOutput signal06 Frequency rangefrom 0 till 16; 31,5; 63; 125; 250; 500; 1000 Hz Supply voltage28(+5,-4) VDCConsumption currentnot more than 110 mAWorking temperature range from -50 till +500Massnot more than 0,61 kgSENSORS AND TRANSDUCERSTransducersSpace industry

  • TransducersSENSORS AND TRANSDUCERS (PSTD)

    SPECIFICATIONVALUEMaximal frequency range, Hz0 1000Tolerance, %, not more than0,5Supply voltage, V28Output signal range, V0 .. 6Operating temperature range, C50 .. +50Current consumption, mA, no more than110Number of channels4Resource time, hours500Weight, kg0,61Number of variants (depends on frequency range)7

  • (SIP)Displacement measuring system is assigned for conversion of a contactless measured axial clearance of a shaft to a standard electric signal for the emergency shutdown system. consists of inductive- transformer sensor of linear displacements and of amplifying and converting block, that are connected by a jumper cable of length 5000 mm.SENSORS AND TRANSDUCERSTransducersSpace industry

  • -7008SPECIFICATIONVALUEnot more than 1 kgMeasuring voltage range0,6-1,15 VSupply voltage27(+5,-4) VDCCurrent consumptionnot more than 250 mA MassTransducer is designed for conversion of signals from semiconductor temperature sensors into input signals for control systems (i.g. 2000).FEATURES: continuity test of measuring sensors; operational integrity under destabilizing factors exposure; high reliability; synchronous and autonomous modesQuantity of sensor channels8 channelsWorking temperature rangefrom -40 till +50 0Sensor supply current1000,1 AMeasuring accuracynot more than 0,16%Output signal 16 bit parallel binary code, pulse duration 10 ms (20 2; 40 4) ms;- Sequential 20 position digit code;Logical 0 level (0 1) V, logical 1 level (4 5) VSENSORS AND TRANSDUCERSTransducersSpace industry

  • 3D200The transducer of linear and angular displacements of pipelines 3D200.It is assigned for measuring of linear and angular displacements (in perpendicular planes) of technological equipment (pipelines) and their transformation into electrical signal that is proportional to displacements.It is used in power plant equipment.SPECIFICATIONVALUEBasic error: - linear displacements - angular displacementsnot more than 1,5%not more than 2%Measuring range: - linear displacements - angular displacements0-220 mm700 Mechanical connection with the unit under measurementMetal wire rope 0,65 mmOverall dimensions217 234 139 Mounting dimensions4 slots 6,460 mm (axle base is 191 mm)Supply voltage61 V, DCMass of the transducernot more than 5,8 SENSORS AND TRANSDUCERSTransducersPower plant industry

  • TransducersSENSORS AND TRANSDUCERS

  • LIMITED LIABILITY COMPANY"SENSOR ENTERPRISE "ZAVOD RAPID

    25, Odintsova str.,Chernigov Ukraine 14030phone (+38 04622)3-23-49, fax (+38 04622)3-16-12

    website: www.rapid.cn.uae-mail: [email protected]