Valerio Moglioni Architect : Personal Poroliocontacts : [email protected] / (+39)3289561334
1. UPS main room 25 sqm2. UPS secondary room 25sqm3. Fire extinguishers room 25sqm
5. Cabinets room 25sqm6. G.E. + G.E.C.A. main room 25sqm7. G.E. + G.E.C.A. aux. room 25sqm8. Storage 25sqm9. Lab 50sqm10. Electrical transformer substation 25sqm
4. Heating room 25sqm15. Executive offices 2516. Directional offices 25sqm17. Directional offices 75sqm
A. Solar system UPS battery pack B. Fuel storage C. Waste collection area
11. Reception12. Main technical room 125sqm13. Maintenance Lab 50sqm14. Secondary technical room 125sqm
GROUND FLOOR PLAN
1 2 3 4
5 6 7 8 9 10
11 12 13 14
15 16 17
A B
C
18. UPS main room 25sqm19. UPS aux. room 25sqm20. TLC networks room 25sqm
22. Installations23. Meeting room 50sqm24. Relief room 25sqm25. Direction and rc room 50sqm26. PSA room 50sqm27. Offices 25sqm
21. Offices 25sqm32. Technical office 50sqm
28. Secretary 25sqm29. Direction office 25sqm30. Admin. office 25sqm31. Admin. office 25sqm
18 19 20 21
22 23 24 25 26
2827 29 30 31
FIRST FLOOR PLAN.
VCR - Plan
VCR lev. I - Plan
VCR lev. II - Plan
A4 - A5: Technical block 533 sqm
A3: Technical block 320 sqm
ENAV offices 410 sqm
A1: VCR LEV. I-II 110 sqm
A0: VCR 64 sqm
Connections/Services 600 sqm
FUNCTIONAL PROGRAM SCHEME
1
2
3
45
6
7
9
10
8
VCR - PLAN.
LEGEND:
1 - 6. ATC workplaces 7. Weather workplace 8. Relief area 9. Installations 10. External footbridge access
EXPLODED AXONOMETRIC VIEW
VCR - 3D INTERIOR VIEW
CROSS SECTION A - A’.
DECEMBER 21 - H 12:00
JUNE 21 - H 12:00
HEAT EXTRACTION
NATURAL VENTILATION
FSOLAR FILM IN AMORPHOUS SILICON
GEOTHERMAL HEAT PUMP
RAINWATER COLLECTION
DETAIL I:Double skin façade with capillar glass system, hosts a capillar system of ventila-tion (heating/cooling) of indoor rooms through serpentines placed between the ventilation grid. Insulating glass used for the VCR lev. I and II has a capillar structu-re to scatter light facing inwards with the purpose to protect against UV rays and glare. In the same way an excellent visibility from inward to outward is provided
1
DETAIL 1
Direct sunlight
Scattered lightScattering slab between glass layers
NATURAL LIGHTING: North façade scattered light
Technical rooms can host a GEOTHERMAL PLANT
DETAIL 1I
DETAIL II:Technical rooms are facing North are provided with natural ventilation and lit by natural scattered light filtrating by big skylights. Hygrothermal sensors provides for automatic opening of the windows and skylights to increase ventilation amount. All the systems are energetycally self sustained by photovoltaic films and panels over external surfaces.TheThe bottom of the complex is designed to provide for thermal insula-tion and to host proper technical rooms for natural ventilation sy-stems and geothermal installation
RAINWATER COLLECTION:Rainwater is collected by a sloping roof and reused for toilets and green areas irrigation.
EQUIPMENTS ROOM - DETAIL.