Materials and Methods Electroencephalograph & Image scanner

Measurement of alpha wave

Subjects:male:8 female:22 total:30 mean age 62 years old

Page 3: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Both wax model denture was finished occlusal adjustment

Conventional wax model removable partial denture

Piezographic wax model removable partial denture

Page 4: Effectiveness of piezography technique for removable partial denture construction 石川佳和

For PPDs, Piezography was applied using silicon impression material, and polished surface was formed according to

the Piezographic space.

For PPDs, Piezography was applied using ADHESIVE

For PPDs, polished surface was applied using silicon impression material

Page 5: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Piezography was applied for each subject was pronounced ,「Sa,Shi,Su,Se,So」

「Ta,Chi,Tsu,Te,To」,after it was doing dry swallow at three times.

Page 6: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Conventional and Piezographic wax model removable partial denture in the mouth

Conventional wax model removable partial denture in the mouth

Piezographic wax model removable partial denture in the mouth

Page 7: Effectiveness of piezography technique for removable partial denture construction 石川佳和

For PPDs, Piezography was applied using silicon impression material, and polished surface was formed according to the

Piezographic space

Wax model denture’s polished surface was used to silicone impression material

Wax model denture’s polished surface was Formed according to the Piezographic space

Page 8: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Both CPD and PPD were fabricated

For conventional removable partial denture (CPD) into the model

For Piezographic removable partial denture (PPD) into the model

Page 9: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Duplicated removable partial denture’s first molar artifical polished surface cutting depth compare CPD with PPD

Page 10: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Duplicated removable partial denture’s first molar artifical polished surface cutting depth compare

CPD with PPD

PPD was depther 1.0 mm than CPD (the right buccal side). PPD was depther 0.9 mm than CPD (the right lingual side).

PPD was depther 1.5 mm than CPD (the left buccal side) PPD was depther 0.7 mm than CPD (the left lingual side)

→ ← → ← → ←

→ ←

Page 11: Effectiveness of piezography technique for removable partial denture construction 石川佳和

Apply Piezography to make removable partial denture

Old denture New denture

Apply Piezography

Subject :78 years old female