Upload
ziya-2009
View
216
Download
0
Embed Size (px)
Citation preview
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 1/8
GSM/EDGE BSS, Rel.
RG20(BSS), Operating
Documentation, Issue 08
Reference
110 PCU Utilisation Measurement
DN70456311
Issue 2-1
Approval Date 2010-05-19
Confidential
Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of
its products and services. We would like to encourage you as our customers and users to join
us in working towards a cleaner, safer environment. Please recycle product packaging and
follow the recommendations for power use and proper disposal of our products and their compo-
nents.
If you should have questions regarding our Environmental Policy or any of the environmental
services we offer, please contact us at Nokia Siemens Networks for any additional information.
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 2/8
2 DN70456311
110 PCU Utilisation Measurement
Id:0900d805808f1e12
Confidential
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the “Legal, Safety
and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,
Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-
satzes.
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 3/8
DN70456311 3
110 PCU Utilisation Measurement
Id:0900d805808f1e12
Confidential
Table of contentsThis document has 8 pages.
1 Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 110 PCU Utilisation Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Counters of PCU Utilisation Measurement . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 110000 / PEAK RESERVED PCUPCM CHANNELS . . . . . . . . . . . . . . . 7
3.2 110001 / PEAK OCCUPIED PDTCH UL . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 110002 / PEAK OCCUPIED PDTCH DL . . . . . . . . . . . . . . . . . . . . . . . . . 8
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 4/8
4 DN70456311
110 PCU Utilisation Measurement
Id:0900d805808f1e12
Confidential
List of tablesTable 1 Measurement description of PCU Utilisation Measurement . . . . . . . . . . 6
Table 2 Counters of PCU Utilisation Measurement . . . . . . . . . . . . . . . . . . . . . . . 6
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 5/8
DN70456311 5
110 PCU Utilisation Measurement Summary of changes
Id:0900d8058080c6a5
Confidential
1 Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Changes made between issues 2-1 and 2-0
The Updated field is modified for the counter 110000 related to BSS21530: mcBSC.
Changes made between issues 2-0 and 1-0
The Description, Updated and Related to feature fields are updated for the counter
110000 related to BSS21454: Packet Abis over IP/Ethernet.
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 6/8
6 DN70456311
110 PCU Utilisation Measurement
Id:0900d8058080c68d
Confidential
110 PCU Utilisation Measurement
2 110 PCU Utilisation MeasurementThis measurement records the peak number of used channels in UL/DL direction per
PCU and the number of occupied packet data traffic channels (PDTCH) per PCU.
This measurement is optional.
Measurement description
Measurement counters
Related topics
• Counters of PCU Utilisation Measurement
Instructions
• BSC Statistics Administration
Reference
• BSC Measurement Counters Displaying Program (FOXMEA)
• Performance Measurements
•
PCU2 Service Terminal Commands
Measurement
Measurement ID
Measurement abbreviation
PCU Utilisation Measurement
110
PCU_UTIL
Product BSC
Product software release S13
Target name PCU
Table 1 Measurement description of PCU Utilisation Measurement
Counter Counter number
PEAK RESERVED PCUPCM CHANNELS 110000
PEAK OCCUPIED PDTCH UL 110001
PEAK OCCUPIED PDTCH DL 110002
Table 2 Counters of PCU Utilisation Measurement
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 7/8
DN70456311 7
110 PCU Utilisation Measurement Counters of PCU Utilisation Measurement
Id:0900d805808f1e14
Confidential
3 Counters of PCU Utilisation Measurement
3.1 110000 / PEAK RESERVED PCUPCM CHANNELS
3.2 110001 / PEAK OCCUPIED PDTCH UL
Counter ID: 110000 Network element name: PEAK RESERVED PCUPCM
CHANNELS
Version: 3.2 NetAct name: PEAK_RESERVED_PCUPCM_CH
Description: Peak number of reserved PCUPCM (16 kbit/s) channels. All reserved
channels within a measurement period are taken into account: GPRS channels,
EGPRS master and slave channels.
With Packet Abis the peak number of maximum possible PCU resource allocation
units (16 kbit/s channel equivalents) according to the maximum MCS for the territory.
Updated: When the sampled value exceeds the current peak value.Counter not updated in PCUM.
Logical type: Max Trigger type: Event Sampling interval:
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature:
BSS20432: Packet Data Optimisation Package
BSS21454: Packet Abis over IP/Ethernet
Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S13 Definition updated in release:S15
Counter ID: 110001 Network element name: PEAK OCCUPIED PDTCH UL
Version: 3.0 NetAct name: PEAK_OCCUPIED_PDTCH_ULDescription: Peak number of simultaneously occupied uplink GPRS/EDGE RTSLs
within a measurement period. RTSL is occupied for the whole TBF duration, also
when there is no transmission.
Updated: When the sampled value exceeds the current peak value.
Logical type: Max Trigger type: Event Sampling interval: 1 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
7/27/2019 PCU Utilisation Measurement.pdf
http://slidepdf.com/reader/full/pcu-utilisation-measurementpdf 8/8
8 DN70456311
110 PCU Utilisation Measurement
Id:0900d805808f1e14
Confidential
Counters of PCU Utilisation Measurement
3.3 110002 / PEAK OCCUPIED PDTCH DL
Related to feature:
BSS20432: Packet Data Optimisation Package
Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S13 Definition updated in release:
Counter ID: 110002 Network element name: PEAK OCCUPIED PDTCH DL
Version: 3.0 NetAct name: PEAK_OCCUPIED_PDTCH_DL
Description: Peak number of simultaneously occupied downlink GPRS/EDGE RTSLs
within a measurement period. RTSL is occupied for the whole TBF duration, also
when there is no transmission.
Updated: When the sampled value exceeds the current peak value.
Logical type: Max Trigger type: Event Sampling interval: 1 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature:
BSS20432: Packet Data Optimisation Package
Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S13 Definition updated in release: