Vacuum-Compact Systems
SIHI modular
PL 26 M, PL 51 M
ANLAGENTECHNIK PL 1133.94400.51.01 E 06/2000
SAT
Pressure range: 33 bis 1013 mbar Suction capacity : 3 bis 58 m/h
DESIGN AND CONSTRUCTION
The SIHImodular
systems consist of a various components which areassembled together to form a compact unit. Each unit can be variedin accordance with the respective application.The LEM liquid ring vacuum pump utilised in these systems is of asingle stage design and of a simple and robust construction with thefollowing features:
Non polluting due to near isothermal compression Oil free, no lubrication in the working chamber Capable of handling nearly all gases and vapours Small quantities of entrained liquid can be handled Easy to maintain and reliable operation Low noise and virtually free from vibration Anti cavitation protection as standard
The SIHI modular systems are offered as a service liquid savingarrangement and can be supplied with or without a heat exchanger.
APPLICATION
As with the other SIHI liquid ring vacuum pumps this type is alsocapable of handling dry and saturated forms of gases. Smallquantities of entrained liquid in the suction gas stream can also bedealt with. The SIHI modular is designed for vacuum applications of between 33-900 mbar, however, this range can be extended whenused in conjunction with the respective gas operated ejector. (Seestandard catalogue for details).
PL 91 M.A.M 55 0.0ANOTE
During its operation, the liquid ring vacuum pump must becontinuously supplied with service liquid, normally water, in order toeliminate the heat resulting from the gas compression, and to preventthe pump from dry running operation. The service liquid is separatedfrom the process gas in a separator. Dependent on the chosenarrangement and proposed application, the necessary service liquidcan be either totally or partially recirculated within the system,conserving the amount of fresh make up liquid required. However,when using the total recirculated arrangement, the operating suctionpressure must be 800 mbar or lower.The direction of rotation is clockwise when viewed from the drive endof the pump.
GENERAL TECHNICAL DATA
Unit PL 26 M PL 51 M
Speed 50 Hz60 Hz
rpm 29003500
Max. Compression over pressure bar 0,3
Max. Admissible pressure difference bar 1,1
Hydraulic test (over pressure) bar 3
Moment of inertia of the rotatingpump parts and of the water filling kg
. m 0,003 0,005
Sound pressure levelat a suction pressure of 80 mbar (standard values) dB (A) 73
Service liquid volume up to shaft level Liter 9,1 9,3
Max. Flow resistance
of the heat exchanger bar 0,2
8/11/2019 PL_26_51_E
2/142
Material design
MATERIAL DESIGNItem COMPONENTS 0A
1 Pump 0A (see materials list of the pump)
2 Base plate steel lacquered
3 Pump carrier steel lacquered
4 Separator steel, galvanized
5 Ball type non-return valve brass / Perbunan
6 EMSR-technology, small fittings brass / steel, galvanized / VA
7 Heat exchanger 1.4401 / Perbunan
8 Tube for protection against cavitation synthetic material9 Electric control steel plate, lacquered
Material design of the pump LEM 26, 51
MATERIAL DESIGNItem COMPONENTS 0A
10.10 Casing 0.6025
13.70 Guide disk 1.4404
16.10 Cover 1.4404
23.50 Vane wheel Impeller 2.1096.0143.30 Standard mechanical seal Cr-steel / carbon / Perbunan
75.11 Valve plate PTFE
8/11/2019 PL_26_51_E
3/143
SIHI modular - Construction types
with combined liquid service without heat exchanger
Vacuum compact system equipped with: Manual service liquid regulation Ball type non-return valve Anti cavitation protection Mounting feet or rubber or mounting rails
Designation M 10 0 (Low Cost-construction type)
Additional options: as above, but thermostatic service liquid regulation
(regulating range 0 - 30 C) Designation M 15 0 (Base-construction type)
as above, but with service liquid low level monitoringdevice for conductive liquids
Designation M 20 0 (High Class-construction type) as above, but with additional standard electric control
Designation M 25 0 (High End-construction type)
PL 91 M.A.M 15 0.0A
with plate heat exchanger (closed circuit)
Vacuum compact system equipped with: Plate heat exchanger (screwed) Thermometer between heat exchanger
and pump Ball type non-return valve Anti cavitation protection Mounting feet or rubber or mounting rails
Designation M 40 0 (Low Cost-construction type)
Additional options: as above, but with level dependent service liquid
replenishing for conductive liquids Designation M 45 0 (Base-construction type)
as above, but with cooling water connection at the heatexchanger, thermostatically regulated(regulating range 0 - 30 C)
Designation M 50 0 (High Class-construction type) as above, but with additional standard electric control
Designation M 55 0 (High End-construction type)
PL 161 M.A.M 50 0.0A
8/11/2019 PL_26_51_E
4/144
Suction volume flow and power absorption PL 26 M
0
10
20
30
40
10 100 1000
suction pressure
s u c
t i o n v o
l u m e
f l o w
2900 rpm
3500 rpm
m/h
40 60 80 200 400 mbar
PL 26 M
0
0,5
1
1,5
10 100 1000
suction pressure
p o w e r a
b s o r p
t i o n
kW
2900 rpm
3500 rpm
40 60 80 200 400 mbar
PL 26 M
The operating data are applicable under the following conditions:
pumping medium : - dry air: 20C- water vapour saturated air: 20C _ _ _ _ _ _ _ _ _ _ _
service liquid: - water: 15C
Discharge pressure 1013 mbar (atmospheric pressure)The suction volume flow is applied to the suction pressureTolerance of the operating data 10%
8/11/2019 PL_26_51_E
5/145
Suction volume flow and power absorption PL 51 M
0
20
40
60
80
10 100 1000
suction pressure
s u c
t i o n v o
l u m e
f l o w
2900 rpm
3500 rpm
m/h
40 60 80 200 400 mbar
PL 51 M
0
1
2
3
10 100 1000
suction pressure
p o w e r a
b s o r p
t i o n
kW
2900 rpm
3500 rpm
40 60 80 200 400 mbar
PL 51 M
The operating data are applicable under the following conditions:
pumping medium : - dry air: 20C- water vapour saturated air: 20C _ _ _ _ _ _ _ _ _ _ _
service liquid: - water: 15C
Discharge pressure 1013 mbar (atmospheric pressure)The suction volume flow is applied to the suction pressureTolerance of the operating data 10%
8/11/2019 PL_26_51_E
6/146
SIHI modular - for combined service liquid without heat exchanger Construction type M 10 0 with: - Manual service liquid regulation(Low Cost-construction type) - Ball type non-return valve
- Anti cavitation protection- Rubber mounting feet or mounting rails
Dimensionselectric motor IP 55 connection connection connection connection connection weight
size kW DN E DN A U A UE UF f h approx.50 Hz 60 Hz gas inlet gas outlet liquid drain separator fresh mm mm kg
DIN 2501 DIN 2501 DIN 2501 drain liquidPL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i 35 618 101PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i 35 618 101PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i 37 631 107PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i 37 631 110
Fresh water requirements in [m/h] dependent on suction pressure, speed and difference in temperature
suction pressure [mbar] 33 120 200 400KB KB KB KB
Speed difference intemperature [C]
FB difference intemperature [C]
FB difference intemperature [C]
FB difference intemperature[C]
FB
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
PL 26 M.A. 2900 0,04 0,07 0,14 0,39 0,05 0,09 0,16 0,36 0,05 0,09 0,15 0,30 0,05 0,08 0,14 0,28PL 26 M.B. 3500 0,06 0,10 0,18 0,07 0,11 0,19 0,07 0,11 0,18 0,07 0,11 0,18PL 51 M.A. 2900 0,07 0,13 0,23 0,48 0,09 0,15 0,24 0,42 0,09 0,14 0,23 0,36 0,09 0,14 0,22 0,34PL 51 M.B. 3500 0,11 0,17 0,28 0,12 0,19 0,28 0,12 0,18 0,26 0,12 0,18 0,25
FB = fresh service liquidKB = combined service liquid with service water 10 C, 5 C, 2 C warmer than the fresh water.
8/11/2019 PL_26_51_E
7/147
SIHI modular - for combined service liquid without heat exchanger Construction type M 15 0 with: -Thermostatic service liquid regulation (0 - 30 C)(Basis-construction type) - Ball type non-return valve
- Anti cavitation protection- Rubber mounting feet or mounting rails
Dimensions
electric motor IP 55 connection connection connection connection connection weightsize kW DN E DN A U A UE UF f h approx.
50 Hz 60 Hz gas inlet gas outlet liquid drain separator fresh mm mm kgDIN 2501 DIN 2501 DIN 2501 drain liquid
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i 35 618 102
PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i 35 618 102PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i 37 631 108PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i 37 631 111
Fresh water requirements in [m/h] dependent on suction pressure, speed and difference in temperature
suction pressure [mbar]33 120 200 400
KB KB KB KBspeed difference in
temperature [C]FB difference in
temperature [C]FB difference in
temperature [C]FB difference in
temperature [C]FB
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
PL 26 M.A. 2900 0,04 0,07 0,14 0,39 0,05 0,09 0,16 0,36 0,05 0,09 0,15 0,30 0,05 0,08 0,14 0,28PL 26 M.B. 3500 0,06 0,10 0,18 0,07 0,11 0,19 0,07 0,11 0,18 0,07 0,11 0,18
PL 51 M.A. 2900 0,07 0,13 0,23 0,48 0,09 0,15 0,24 0,42 0,09 0,14 0,23 0,36 0,09 0,14 0,22 0,34PL 51 M.B. 3500 0,11 0,17 0,28 0,12 0,19 0,28 0,12 0,18 0,26 0,12 0,18 0,25
FB = fresh service liquidKB = combined service liquid with service water 10 C, 5 C, 2 C warmer than the fresh water.
8/11/2019 PL_26_51_E
8/148
SIHI modular - for combined service liquid without heat exchanger Construction type M 20 0 with: - Thermostatic service liquid regulation (0 - 30 C)(High Class-construction type) - Ball type non-return valve
- Anti cavitation protection- Rubber mounting feet or mounting rails- Additional service liquid low level monitoring device for conductive liquids
Dimensions
electric motor IP 55 connection connection connection connection connection weightsize kW DN E DN A U A UE UF f h approx.
50 Hz 60 Hz gas inlet gas outlet liquid drain separator fresh mm mm kgDIN 2501 DIN 2501 DIN 2501 drain liquid
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i 35 618 107
PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i 35 618 107PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i 37 631 113PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i 37 631 116
Fresh water requirements in [m/h] dependent on suction pressure, speed and difference in temperature
suction pressure [mbar] 33 120 200 400KB KB KB KB
speed difference intemperature [C]
FB difference intemperature [C]
FB difference intemperature [C]
FB difference intemperature [C]
FB
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
PL 26 M.A. 2900 0,04 0,07 0,14 0,39 0,05 0,09 0,16 0,36 0,05 0,09 0,15 0,30 0,05 0,08 0,14 0,28PL 26 M.B. 3500 0,06 0,10 0,18 0,07 0,11 0,19 0,07 0,11 0,18 0,07 0,11 0,18
PL 51 M.A. 2900 0,07 0,13 0,23 0,48 0,09 0,15 0,24 0,42 0,09 0,14 0,23 0,36 0,09 0,14 0,22 0,34PL 51 M.B. 3500 0,11 0,17 0,28 0,12 0,19 0,28 0,12 0,18 0,26 0,12 0,18 0,25
FB = fresh service liquidKB = combined service liquid with service water 10 C, 5 C, 2 C warmer than the fresh water.
8/11/2019 PL_26_51_E
9/149
SIHI modular - for combined service liquid without heat exchanger Construction type M 25 0 with: - Thermostatic service liquid regulation (0 - 30 C)(High End-construction type) - Ball type non-return valve
- Anti cavitation protection- Rubber mounting feet or mounting rails- Additional service liquid low level monitoring device for conductive liquids- Additional standard electric control, steel plate enclosed
Dimensions
electric motor IP 55 connection connection connection connection connection weightsize kW DN E DN A U A UE UF f h approx.
50 Hz 60 Hz gas inlet gas outlet liquid drain separator fresh mm mm kgDIN 2501 DIN 2501 DIN 2501 drain liquid
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i 35 618 147
PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i 35 618 147PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i 37 631 153PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i 37 631 156
Fresh water requirements in [m/h] dependent on suction pressure, speed and difference in temperature
suction pressure [mbar]33 120 200 400
KB KB KB KBspeed difference in
temperature [C]FB difference in
temperature [C]FB difference in
temperature [C]FB difference in
temperature [C]FB
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
PL 26 M.A. 2900 0,04 0,07 0,14 0,39 0,05 0,09 0,16 0,36 0,05 0,09 0,15 0,30 0,05 0,08 0,14 0,28PL 26 M.B. 3500 0,06 0,10 0,18 0,07 0,11 0,19 0,07 0,11 0,18 0,07 0,11 0,18
PL 51 M.A. 2900 0,07 0,13 0,23 0,48 0,09 0,15 0,24 0,42 0,09 0,14 0,23 0,36 0,09 0,14 0,22 0,34PL 51 M.B. 3500 0,11 0,17 0,28 0,12 0,19 0,28 0,12 0,18 0,26 0,12 0,18 0,25
FB = fresh service liquidKB = combined service liquid with service water 10 C, 5 C, 2 C warmer than the fresh water.
8/11/2019 PL_26_51_E
10/1410
SIHI modular - with plate heat exchanger (closed circuit)Construction type M 40 0 with: - Plate heat exchanger (screwed)(Low Cost-construction type) - Thermometer between heat exchanger and pump
- Ball type non-return valve- Anti cavitation protection- Rubber mounting feet or mounting rails
Dimensions
electric motor IP 55 connection connection connection connection connection connection connection weightsize kW DN E DN A U A UE UF KE K A f h approx.
50 60 gas inlet gas outlet liquid drain separator fresh cold water cold water mm mm kgHz Hz DIN 2501 DIN 2501 DIN 2501 drain liquid inlet outlet
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i G i G i 35 618 128PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i G i G i 35 618 128PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i G i G i 37 631 134PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i G i G i 37 631 137
Cooling liquid data for the cold side of the heat exchanger
Cooling liquid Inlet temperature[C]
Outlet temperature[C]
Flow rate[m/h]
Pressure loss[bar]
PL 26 M.A. water 12 15 0,4 0,3PL 26 M.B. water 12 15 0,5 0,4PL 51 M.A. water 12 15 0,6 0,5PL 51 M.B. water 12 15 0,9 0,8
8/11/2019 PL_26_51_E
11/1411
SIHI modular - with plate heat exchanger (closed circuit)Construction type M 45 0 with: - Plate heat exchanger (screwed)(Basis-construction type) - Thermometer between heat exchanger and pump
- Ball type non-return valve- Anti cavitation protection- Rubber mounting feet or mounting rails- Additional service liquid replenishing for conductive liquids, level dependent
Dimensions
electric motor IP 55 connection connection connection connection connection connection connection weightsize kW DN E DN A U A UE UF KE K A f h approx.
50 60 gas inlet gas outlet liquid drain separator fresh cold water cold water mm mm kgHz Hz DIN 2501 DIN 2501 DIN 2501 drain liquid inlet outlet
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i G i G i 35 618 137PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i G i G i 35 618 137PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i G i G i 37 631 143PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i G i G i 37 631 146
Cooling liquid data for the cold side of the heat exchanger
Cooling liquid Inlet temperature[C]
Outlet temperature[C]
Flow rate[m/h]
Pressure loss[bar]
PL 26 M.A. water 12 15 0,4 0,3PL 26 M.B. water 12 15 0,5 0,4
PL 51 M.A. water 12 15 0,6 0,5PL 51 M.B. water 12 15 0,9 0,8
8/11/2019 PL_26_51_E
12/1412
SIHI modular - with plate heat exchanger (closed circuit)Construction type M 50 0 with: - Plate heat exchanger (screwed)(High Class-construction type) - Thermometer between heat exchanger and pump
- Ball type non-return valve- Anti cavitation protection- Rubber mounting feet or mounting rails- Additional service replenishing for conductive liquids, level dependent- Additional cooling water connection at the heat exchanger, thermostatically regulated (0 - 30 C)
Dimensions
electric motor IP 55 connection connection connection connection connection connection connection weightsize kW DN E DN A U A UE UF KE K A f h approw.
50 60 gas inlet gas outlet liquid drain separator fresh cold water cold water mm mm kgHz Hz DIN 2501 DIN 2501 DIN 2501 drain liquid inlet outlet
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i G i G i 35 618 149PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i G i G i 35 618 149PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i G i G i 37 631 155PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i G i G i 37 631 158
Cooling liquid data for the cold side of the heat exchanger
cooling liquid Inlet temperature[C]
Outlet temperature[C]
Flow rate[m/h]
Pressure loss[bar]
PL 26 M.A. water 12 15 0,4 0,8
PL 26 M.B. water 12 15 0,5 0,9PL 51 M.A. water 12 15 0,6 1,0PL 51 M.B. water 12 15 0,9 1,3
8/11/2019 PL_26_51_E
13/1413
SIHI modular - with plate heat exchanger (closed circuit)Construction type M 55 0 with: - Plate heat exchanger (screwed)(High End-construction type) - Thermometer between heat exchanger and pump
- Ball type non-return valve- Anti cavitation protection- Rubber mounting feet or mounting rails- Additional service liquid replenishing for conductive liquids, level dependent- Additional cooling water connection at the heat exchanger, thermostatically regulated (0 - 30 C)- Additional Standard electric control, steel plate enclosed
Dimensions
electric motor IP 55 connection connection connection connection connection connection connection weightsize kW DN E DN A U A UE UF KE K A f h approx.
50 60 gas inlet gas outlet liquid drain separator fresh cold water cold water mm mm kgHz Hz DIN 2501 DIN 2501 DIN 2501 drain liquid inlet outlet
PL 26 M.A. 80 0,75 - DN 25 DN 40 DN 20 G a G i G i G i 35 618 189PL 26 M.B. 80 - 1,1 DN 25 DN 40 DN 20 G a G i G i G i 35 618 189PL 51 M.A. 90 S 1,5 - DN 25 DN 40 DN 20 G a G i G i G i 37 631 195PL 51 M.B. 90 L - 2,2 DN 25 DN 40 DN 20 G a G i G i G i 37 631 198
Cooling liquid data for the cold side of the heat exchanger
Cooling liquid Inlet temperature[C]
Outlet temperature[C]
Flow rate[m/h]
Pressure loss[bar]
PL 26 M.A. water 12 15 0,4 0,8PL 26 M.B. water 12 15 0,5 0,9PL 51 M.A. water 12 15 0,6 1,0PL 51 M.B. water 12 15 0,9 1,3
8/11/2019 PL_26_51_E
14/14
Explanation of the type code
Series Pump Mains frequency Design Material design
26
51
LEM 26 AZ AAE 0A 7 **
LEM 51 AZ AAE 0A 7 **
** see motor selection table
A
B
50 Hz
60 Hz
M 10 0
to
M 55 0
see page 3 0A see page 2
M 10 0
M 15 026 M A M 20 0
PL 51 M B M 25 0 0A
M 40 0
M 45 0
M 50 0
M 55 0
Motor selection table
Motor enclosure IP 55 50 Hz Motor enclosure IP 55 60 Hz
Y-voltageV +/- 5%
-voltageV +/- 5%
power kW
size- motor-design.
Y-voltageV +/- 5%
-voltageV +/- 5%
power kW
size motor-design.
PL 26 346-440 200-254 0,75 80 AW 346-480 200-277 1,1 80 BW
PL 51 346-440 200-254 1,5 90 S AW 346-480 200-277 2,2 90 L BW
Remarks:
Standard systems will be supplied with solenoid valve coils 230 V, 50 Hz and upon special request with coils 24 V DC without extra price.Level monitoring devices need a supply voltage of 230 V, 50 Hz.The mentioned standard electric controls are equipped with a separate control transformer 400 / 230 V, 50 Hz .
Systems for other voltages and frequencies available on request.Other material combinations upon request.Level monitoring devices for non-conductive liquids upon request.
Accessories:
Suitable system accessories are available:- Gas ejector, type GEV 250 A for a service liquid temperature of 15 C- Gas ejector, type GEV 250 B for a service liquid temperature of 30 C- Preseparator with flushing and draining connection for the separation of solids at suction side.- Ball valve G 1 for draining of the separator.
Any changes in the interest of the technical development are reserved.
S I H I A n l a g e n t e c h n i k G m b HLindenstrasse 170, 25524 Itzehoe, Germany, Telephone +49 (0) 4821 / 771-464, Fax +49 (0) 4821 / 771-501